ECG Machine trade,ECG Machine offer, Sell leads
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
Select to
Page 8 of 13
  • ECG Cable

    Category ECG Cables and Leadwires
    Part Number PM ECG-04(S)
    Part Name ECG 3 leads cable with snaps (common style)
    Compatibility Compatible for use with Series of Monitors: BCI, CSI, IVY, Critikon, MDE,
    Physio Control
    Connector Type 6-pin male
    Cable Length 3.2 metres
    Characteristics AHA or IEC color coding.
    Specifications Refer to ECG Cable catalogue


    Company: Pan-SW Med Corp
  • ARI-600G Digital 6 Channel ECG

    ARI-600G Digital 6 Channel ECG
     
    Features of ARI-600G ECG:
    --Simultaneously acquisition of 12-lead ECG data, IEC Class I, type CF safety standard
    --Selectable four modes of leads
    --Function of ECG parameters measurement and distinguish point printing under automatic mode
    --LCD display of operation menu on ECG, ECG waveform, AMP menu and parameter setting
    --Powerful filter for AC,EMG and DFT interference
    --AC and DC power supply, rechargeable built-in battery in ECG
    --High resolution and multiple print formats ensure best print quality of ECG waveforms
    --Capability of the input & output for analog signal
    --RS232
     
    Specifications of ARI-600G ECG:
    Input Circuit: Floating; protection against defibrillator effect of ECG
    Lead: Standard 12 leads, European leads
    Input Impedance: >50MΩ
    Calibrating Voltage: 1mV±2%
    Digital Sampling:12 bits (simultaneously acquisition of 12 leads ECG data)
    DFT Filter Automatic Adjustment in ECG
    Sensitivity: auto, 2.5, 5, 10, 20mm/mV
    Recording System: Thermal-array
    Paper Speed: 6.25,12.5, 25, 50mm/s(±3%)
    Safety: Standard IEC class I, type CF
    Power Supply AC: 96V~240V,50/60Hz±1Hz
    DC: 14.4V~2000mAh rechargeable battery in ECG
    Depolarization Voltage:±500mV
     
     


    Company: ARI Medical Equipment Co.,Ltd
  • ARI-600G Digital 6 Channel ECG

    ARI-600G Digital 6 Channel ECG
     
    Features of ARI-600G ECG:
    --Simultaneously acquisition of 12-lead ECG data, IEC Class I, type CF safety standard
    --Selectable four modes of leads
    --Function of ECG parameters measurement and distinguish point printing under automatic mode
    --LCD display of operation menu on ECG, ECG waveform, AMP menu and parameter setting
    --Powerful filter for AC,EMG and DFT interference
    --AC and DC power supply, rechargeable built-in battery in ECG
    --High resolution and multiple print formats ensure best print quality of ECG waveforms
    --Capability of the input & output for analog signal
    --RS232
     
    Specifications of ARI-600G ECG:
    Input Circuit: Floating; protection against defibrillator effect of ECG
    Lead: Standard 12 leads, European leads
    Input Impedance: >50MΩ
    Calibrating Voltage: 1mV±2%
    Digital Sampling:12 bits (simultaneously acquisition of 12 leads ECG data)
    DFT Filter Automatic Adjustment in ECG
    Sensitivity: auto, 2.5, 5, 10, 20mm/mV
    Recording System: Thermal-array
    Paper Speed: 6.25,12.5, 25, 50mm/s(±3%)
    Safety: Standard IEC class I, type CF
    Power Supply AC: 96V~240V,50/60Hz±1Hz
    DC: 14.4V~2000mAh rechargeable battery in ECG
    Depolarization Voltage:±500mV
     
     


    Company: ARI Medical Equipment Co.,Ltd
  • Electrocardiograph   ECG203

    Features:
    Digital isolation technology is for minimizing component drift v/s time& temperature to guarantee high-adaptability of the equipment to the environment.

    Digital signal processor for effective inhibition of baseline drift, AC interference filter, EMG interference filter and the heart rate, to guarantee the authenticity and dependability.

    Auto-regulation of baseline drift can effectively inhibit baseline drift, optimizing the printing position to achieve high-quality ECG.

    With a high–resolution thermal printer to print out ECG waveform, describing the trace clear and accurate, annotation as well as related parameters for diagnostic reference.

    Roll recording paper for ECG-203 is 63mm in width, simultaneous 12 lead acquisition, and 3 lead live record, high affectivity of ECG examination, good effect and economic utility.

    Function of rhythm lead for observing abnormal ECG trace & heart rate.

    Supported by AC/Rechargeable battery for continuous examination whenever is necessary. For battery operation, ECG-203 is equipped with a battery charger and a system for battery capacity management and protection.

    Safety level for ECG-203 corresponds to Type CF, Class I according to the GB9706.1-1995 criterion.

    Specifications:
    Lead: Standard 12 leads, changing lead automatically

    Input mode: Floating input circuit; Protection against defibrillation effect

    leakage current: <10uA

    Input Impedance≥50MΩ

    Calibration Voltage: 1mV(±3%)

    Sampling rate: 1ms

    A/D Converter: 12bit

    frequency response: 0.05Hz-150Hz(-3dB)

    time constant: >3.2s

    CMRR: >80dB  >100dB(with filter)

    CMRR: >80dB; >100dB(with AC filter in use)

    35Hz(-3dB)/25Hz(-3dB)EMG Interference filter: 35Hz(-3dB)/25Hz(-3dB)

    Recording Mode: Thermal printer

    Paper Speed: 25.50mm/s±3%

    Paper Size: 63mmx20m/63mmx30m, roll type: <50nA

    input loop current:
    DC output:10mm/V,single output port: >100KΩ

    DC external input: 10mm/V,single end input: >100KΩ

    ECG output:0.5V/mV,single end output: <100Ω

    Safety Standard: I-CF, Protector form defibrillation

    300mV anti-polarization voltage: <15u Vp-p

    Noise Level : <15µVP-P

    Power: AC 220V 50Hz/110V 60Hz;  DC 12V

    Packaging collocation:
    Single unit Dimension: 41cm2×7.5cm1×7cm

    Gross weight: 5kg

    Normative collocation: manufacturer's  identify certificate 1 piece, packing list 1 piece, eligibility card 1 piece, warranty card 1 piece,63mm Thermal Recording Paper 1 roll, patient cable 1 piece, Three plugged power cable 1 piece, limb electrode(limb nip) 4 pcs, chest electrode (sucking ball) 6 pcs, AC electric fuse 2 pieces, user manual 1 pcs, Grounding Cable 1 pcs
     

    Company: Shenzhen Bestman Instument Co., Ltd
  • Electrocardiograph   ECG203

    Features:
    Digital isolation technology is for minimizing component drift v/s time& temperature to guarantee high-adaptability of the equipment to the environment.

    Digital signal processor for effective inhibition of baseline drift, AC interference filter, EMG interference filter and the heart rate, to guarantee the authenticity and dependability.

    Auto-regulation of baseline drift can effectively inhibit baseline drift, optimizing the printing position to achieve high-quality ECG.

    With a high–resolution thermal printer to print out ECG waveform, describing the trace clear and accurate, annotation as well as related parameters for diagnostic reference.

    Roll recording paper for ECG-203 is 63mm in width, simultaneous 12 lead acquisition, and 3 lead live record, high affectivity of ECG examination, good effect and economic utility.

    Function of rhythm lead for observing abnormal ECG trace & heart rate.

    Supported by AC/Rechargeable battery for continuous examination whenever is necessary. For battery operation, ECG-203 is equipped with a battery charger and a system for battery capacity management and protection.

    Safety level for ECG-203 corresponds to Type CF, Class I according to the GB9706.1-1995 criterion.

    Specifications:
    Lead: Standard 12 leads, changing lead automatically

    Input mode: Floating input circuit; Protection against defibrillation effect

    leakage current: <10uA

    Input Impedance≥50MΩ

    Calibration Voltage: 1mV(±3%)

    Sampling rate: 1ms

    A/D Converter: 12bit

    frequency response: 0.05Hz-150Hz(-3dB)

    time constant: >3.2s

    CMRR: >80dB  >100dB(with filter)

    CMRR: >80dB; >100dB(with AC filter in use)

    35Hz(-3dB)/25Hz(-3dB)EMG Interference filter: 35Hz(-3dB)/25Hz(-3dB)

    Recording Mode: Thermal printer

    Paper Speed: 25.50mm/s±3%

    Paper Size: 63mmx20m/63mmx30m, roll type: <50nA

    input loop current:
    DC output:10mm/V,single output port: >100KΩ

    DC external input: 10mm/V,single end input: >100KΩ

    ECG output:0.5V/mV,single end output: <100Ω

    Safety Standard: I-CF, Protector form defibrillation

    300mV anti-polarization voltage: <15u Vp-p

    Noise Level : <15µVP-P

    Power: AC 220V 50Hz/110V 60Hz;  DC 12V

    Packaging collocation:
    Single unit Dimension: 41cm2×7.5cm1×7cm

    Gross weight: 5kg

    Normative collocation: manufacturer's  identify certificate 1 piece, packing list 1 piece, eligibility card 1 piece, warranty card 1 piece,63mm Thermal Recording Paper 1 roll, patient cable 1 piece, Three plugged power cable 1 piece, limb electrode(limb nip) 4 pcs, chest electrode (sucking ball) 6 pcs, AC electric fuse 2 pieces, user manual 1 pcs, Grounding Cable 1 pcs
     

    Company: Shenzhen Bestman Instument Co., Ltd
  • Electrocardiograph   ECG200B

    Features:
    Large LCD screen display the ECG trace, designed with digital isolation technology and digital signal processor for guaranteeing the authenticity and dependability;

    High –resolution thermal printer to print out ECG waveform, describing the trace clear and accurate.

    Auto-regulation of baseline drift can effectively inhibit baseline drift, Auto-regulation of baseline drift can effectively inhibit baseline drift.

    Output system of high-definition linear array (8 dot/mm),do not need any adjustment, the frequency of record is up to 150Hz.

    In automatic mode, if the patient cable is in abnormal condition, please continuous press MODE  button to observe the record.

    Design corresponds to IEC CF, the amplifier is floating input circuit

    Have AC/DC two kinds of operation, contains Ni-MH rechargeable battery, can continuously record 80 pieces of ECG trace in the best DC condition.

    ECG-200B is matched graphic LCD

    Specifications:
    Lead: Standard 12 leads, changing lead automatically;

    Input mode: Floating input circuit; Protection against defibrillation effect

    leakage current: <10uA

    Input Impedance:≥50MΩ

    Calibration Voltage: 1mV(±3%)

    Sampling rate: 1ms

    A/D Converter: 12bit

    Frequency response: 0.05Hz-150Hz(-3dB)

    Time constant: >3.2s
    CMRR : >80dB;  >100dB(with AC filter in use)

    EMG Interference filter: 35Hz(-3dB)/25Hz(-3dB

    Recording Mode: Thermal printer

    Paper Speed: 25.50mm/s±3%

    Paper Size: 63mmx20m/63mmx30m, roll type

    Input loop current: < 50nA

    DC external input: 10mm/V, single end input: > 100KΩ

    ECG output:0.5V/mV,single end output: <100Ω

    Safety Standard: I-CF, Protector form defibrillation

    Anti-polarization voltage: 300mV

    Noise Level: <15µVP-P

    Power: AC 220V 50Hz/110V 60Hz,     DC 12V

    Packaging collocation:
    Single unit Dimension: 41cmx27.5cmx17cm

    Gross weight: 5kg
     
    Normal collocation: manufacturer's  identify certificate 1 pcs, packing list 1 pcs, eligibility card 1 pcs, warranty card 1 pcs,50mm Thermal Recording Paper 1 roll, patient cable 1 pcs, Three plugged power cable 1 pcs, limb electrode(limb nip) 4 pcs, chest electrode (sucking ball) 6 pcs, AC electric fuse 2 pcs, user manual 1 pcs, Grounding Cable 1 pcs
     

    Company: Shenzhen Bestman Instument Co., Ltd
  • Electrocardiograph   ECG200B

    Features:
    Large LCD screen display the ECG trace, designed with digital isolation technology and digital signal processor for guaranteeing the authenticity and dependability;

    High –resolution thermal printer to print out ECG waveform, describing the trace clear and accurate.

    Auto-regulation of baseline drift can effectively inhibit baseline drift, Auto-regulation of baseline drift can effectively inhibit baseline drift.

    Output system of high-definition linear array (8 dot/mm),do not need any adjustment, the frequency of record is up to 150Hz.

    In automatic mode, if the patient cable is in abnormal condition, please continuous press MODE  button to observe the record.

    Design corresponds to IEC CF, the amplifier is floating input circuit

    Have AC/DC two kinds of operation, contains Ni-MH rechargeable battery, can continuously record 80 pieces of ECG trace in the best DC condition.

    ECG-200B is matched graphic LCD

    Specifications:
    Lead: Standard 12 leads, changing lead automatically;

    Input mode: Floating input circuit; Protection against defibrillation effect

    leakage current: <10uA

    Input Impedance:≥50MΩ

    Calibration Voltage: 1mV(±3%)

    Sampling rate: 1ms

    A/D Converter: 12bit

    Frequency response: 0.05Hz-150Hz(-3dB)

    Time constant: >3.2s
    CMRR : >80dB;  >100dB(with AC filter in use)

    EMG Interference filter: 35Hz(-3dB)/25Hz(-3dB

    Recording Mode: Thermal printer

    Paper Speed: 25.50mm/s±3%

    Paper Size: 63mmx20m/63mmx30m, roll type

    Input loop current: < 50nA

    DC external input: 10mm/V, single end input: > 100KΩ

    ECG output:0.5V/mV,single end output: <100Ω

    Safety Standard: I-CF, Protector form defibrillation

    Anti-polarization voltage: 300mV

    Noise Level: <15µVP-P

    Power: AC 220V 50Hz/110V 60Hz,     DC 12V

    Packaging collocation:
    Single unit Dimension: 41cmx27.5cmx17cm

    Gross weight: 5kg
     
    Normal collocation: manufacturer's  identify certificate 1 pcs, packing list 1 pcs, eligibility card 1 pcs, warranty card 1 pcs,50mm Thermal Recording Paper 1 roll, patient cable 1 pcs, Three plugged power cable 1 pcs, limb electrode(limb nip) 4 pcs, chest electrode (sucking ball) 6 pcs, AC electric fuse 2 pcs, user manual 1 pcs, Grounding Cable 1 pcs
     

    Company: Shenzhen Bestman Instument Co., Ltd
  • Electrocardiograph   ECG213
    Features:
    With auto-interpretation function; can assist doctor to diagnose;

    Color LCD makes the images more clear for guaranteeing the reliability of the images ;

    Designed with technology of Digital Signal Processing and Digital Isolation;

    Synchronously 12 lead acquisition and printing 3 live leads record of them,Using high resolution
    thermal roll paper for recording ECG waveform, Multiple optional digital filter ( including baseline
    drift filter ),using auto-regulation baseline drift filter which can inhibit any baseline drift ,or curb
    caused by patient's movement and auto- optimize the position for printing;

    Auto measurement / analysis system shows the real-time heart rate which makes it easier for
    doctor's diagnosis;

    Can store maximum of 128 patients' ECG data and enable user to replay data analyze and print it
    from database;

    High-speed USB interface and traditional RS-232 interface are both built–in for communicating
    with computer as well as other devices;

    Data can be received through one of the interfaces and displayed by the software which is also
    provided by our company (optional);

    Specifications:
    LCD display: 640×480  TFT  5.7 inch graphic LCD

    Lead: standard 12 leads

    Sampling method: 12 leads synchronously acquisition

    CMRR: >80dB, > 100dB  (with AC filter)

    Sensitivity: AUTO;2.5; 5; 10; 20 mm / mV

    Paper speed: 6.25; 12.5; 25; 50 mm / s( ± 3%)

    Paper size: 80mm x 30m roll type

    Recording mode: Thermal Array printing

    Power supply: AC: 110-230V (±10%) , 50/60 Hz±1Hz; 40 VA
                               DC: 14.4V rechargeable Li-ion battery

    Package collocation:
    Single unit size:  31 x 23.5 x 6.6 (cm)   Net weight: 3.8 kg ; Gross weight:5.5 kg

    Normal collocation: roll paper, patient cable, power cable, limb electrode (limbnip) 4 pcs, chest
                                        electrode ( sucking ball ) 6 pcs,  AC electric fuse 2 purchase.

    Company: Shenzhen Bestman Instument Co., Ltd
  • Electrocardiograph   ECG213
    Features:
    With auto-interpretation function; can assist doctor to diagnose;

    Color LCD makes the images more clear for guaranteeing the reliability of the images ;

    Designed with technology of Digital Signal Processing and Digital Isolation;

    Synchronously 12 lead acquisition and printing 3 live leads record of them,Using high resolution
    thermal roll paper for recording ECG waveform, Multiple optional digital filter ( including baseline
    drift filter ),using auto-regulation baseline drift filter which can inhibit any baseline drift ,or curb
    caused by patient's movement and auto- optimize the position for printing;

    Auto measurement / analysis system shows the real-time heart rate which makes it easier for
    doctor's diagnosis;

    Can store maximum of 128 patients' ECG data and enable user to replay data analyze and print it
    from database;

    High-speed USB interface and traditional RS-232 interface are both built–in for communicating
    with computer as well as other devices;

    Data can be received through one of the interfaces and displayed by the software which is also
    provided by our company (optional);

    Specifications:
    LCD display: 640×480  TFT  5.7 inch graphic LCD

    Lead: standard 12 leads

    Sampling method: 12 leads synchronously acquisition

    CMRR: >80dB, > 100dB  (with AC filter)

    Sensitivity: AUTO;2.5; 5; 10; 20 mm / mV

    Paper speed: 6.25; 12.5; 25; 50 mm / s( ± 3%)

    Paper size: 80mm x 30m roll type

    Recording mode: Thermal Array printing

    Power supply: AC: 110-230V (±10%) , 50/60 Hz±1Hz; 40 VA
                               DC: 14.4V rechargeable Li-ion battery

    Package collocation:
    Single unit size:  31 x 23.5 x 6.6 (cm)   Net weight: 3.8 kg ; Gross weight:5.5 kg

    Normal collocation: roll paper, patient cable, power cable, limb electrode (limbnip) 4 pcs, chest
                                        electrode ( sucking ball ) 6 pcs,  AC electric fuse 2 purchase.

    Company: Shenzhen Bestman Instument Co., Ltd
  • Electrocardiograph   ECG200A

     
    Features:

    ECG-200A is designed with digital isolation technology and digital signal processor for guaranteeing the authenticity and dependability;

    High-resolution thermal printer can print out ECG waveform, describing the trace clear and accurate;

    Auto-regulation of baseline drift can effectively inhibit baseline drift;

    Output system of high-definition linear array (8dot/mm), do not need any adjustment, the frequency of record is up to 150Hz;

    In automatic mode, if the patient cable is in abnormal condition, please continuous press MODE  button to observe the record;

    Design corresponds to IEC, CF, the amplifier is floating input circuit;

    Have AC/DC two kinds of operation contains Ni-MH rechargeable battery, can continuously record 80 pieces of ECG trace in the best DC condition.

    Specifications:
    Lead: Standard 12 leads, changing lead automatically

    Input mode: Floating input circuit; Protection against defibrillation effect

    Leakage current: < 10uA

    Input Impedance: ≥50MΩ

    Calibration Voltage: 1mV(±3%)

    Sampling rate:1ms

    A/D Converter: 12bit

    Frequency response: 0.05Hz-150Hz(-3dB)

    Time constant: >3.2s

    CMRR: >80dB; >100dB(with AC filter in use)

    35Hz(-3dB)/25Hz(-3dB)EMG Interference filter: 35Hz(-3dB)/25Hz(-3dB

    Recording Mode: Thermal printer

    Paper Speed: 25.50 mm/s±3%

    Paper Size: 63mmx20m/63mmx30m, roll type

    Input loop current: < 50nA

    DC external input: 10mm/V, single end input: >100KΩ

    ECG output: 0.5V/mV,single end output: < 100Ω

    Safety Standard: I-CF, Protector form defibrillation

    300mV anti-polarization voltage:

    Noise Level: < 15µVP-P

    Power:AC 220V 50Hz/110V 60Hz;   DC 12V

    Packaging collocation:
    Single unit Dimension: 41cmx27.5cm1x7cm

    Gross weight: 5kg

    Normative collocation: manufacturer's identify certificate 1 pcs, packing list 1 pcs, eligibility card 1 pcs, warranty card 1 pcs,50mm Thermal Recording Paper 1 roll, patient cable 1 pcs, Three plugged power cable 1 pcs, limb electrode(limb nip) 4 pcs, chest electrode (sucking ball) 6 pcs, AC electric fuse 2 pcs, user manual 1 pcs, Grounding Cable 1 pcs
     


    Company: Shenzhen Bestman Instument Co., Ltd
Select to
Page 8 of 13    ...... 8
Go to Page