Multi-Parameter Monitor trade,Multi-Parameter Monitor offer, Sell leads
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
Select to
Page 7 of 14
  • Critikon Adult Finger Clip Spo2 Sensor

    Desciption: Critikon Adult Finger Clip Spo2 Sensor, L=3m

    Connector Guide: Lemo 7-Pins

    Compatibility: (GE Medical Systems)Critikon Dinamap 8700

    Critikon Dinamap 8710, Critikon Dinamap 8720 Plus

     

    TPU jacket with good flexibility, soft and durable. gilt pins for connectors with the machines, which enables good conductivity. Famous brand receiver and emitter.
    Other brands products are available.
    As a leading manufacturer of ECG cables, SPO2 sensors, SPO2 cables, reusable ECG electrodes in China, We are proud of that we are now supplying those products to all over the world with good quality and price, responsible and fast service. Long time experience in this industry gifts us with a large stock of products data with all kinds of sensors and cables. Many customers found their long “obsolete” partner for their old machines like HP 78833B, M1275 etc. Manufacturers for ECG machines trust us with their latest models products.
    We also have stocks of other ECG/EKG cables, ECG/EKG leadwires, SPO2 sensors, SPO2 cables, SPO2 extension cables, reusable ECG electrodes, NIBP cables, transducers, cuffs etc.
    Our factory and our innovation for this industry always ready to manufacture products for you for OEM, ODM. Retail or wholesale are available (Of course, price is different due to different costs to manufacture. And it is cost-effective for you of course.).
    Pls contact us for more details with this product and more products.
    For more details, pls call: 862028961025 or visit our website
    www.chino86.com


    Company: Pan-SW Med Corp
  • ARI-6000 Multi-parameter Monitor


    ARI-6000 Multi-parameter Monitor
     
    Features of ARI-6000 Patient Monitor:
    -- 8.4″ color TFT display
    -- Patient Monitor Suitable for adult, pediatric and neonatal patient
    -- Basic parameters (ECG, Spo2, NIBP) in a durable case for bedside monitoring and transport
    -- Audible and visual alarms with adjustable alarm ranges in patient monitor
    -- Networkable with CONTEC central monitoring system in this patient monitor
    -- Powerful data management and storage capacity patient monitor
     
    Standard Configuration of ARI-6000 Patient Monitor:
    -- ECG, NIBP, Spo2
     
    ECG of ARI-6000 Patient Monitor:
    -- Lead type:5-lead
    -- Input: RA; LA; RL; LL; V
    -- Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
    -- Accuracy: ±2bpm or ±2%, whichever is greater
    -- Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
    -- S-T detection: YES, Arrhythmia analysis: YES
    -- Alarm: YES, audible and visual alarm, alarm events recallable
     
    NIBP of ARI-6000 Patient Monitor:
    -- Method: Oscillometry
    -- Operation modes: Manual/Automatic/STAT
    -- Measurement unit: mmHg/KPa selectable
    -- Measurement types: Systolic, Diastolic, Mean
    -- Over-pressure protection: YES
     
    Spo2 of ARI-6000 Patient Monitor:
    -- Measurement range: 0-100%
    -- Accuracy: ±2% (70~100%); 0~69% unspecified
     
    Optional parts of ARI-6000 Patient Monitor:
    -- RESP,2-TEMP,2-IBP,ETCO2,Network,Thermal Recorder

     


    Company: ARI Medical Equipment Co.,Ltd
  • ARI-6000 Multi-parameter Monitor


    ARI-6000 Multi-parameter Monitor
     
    Features of ARI-6000 Patient Monitor:
    -- 8.4″ color TFT display
    -- Patient Monitor Suitable for adult, pediatric and neonatal patient
    -- Basic parameters (ECG, Spo2, NIBP) in a durable case for bedside monitoring and transport
    -- Audible and visual alarms with adjustable alarm ranges in patient monitor
    -- Networkable with CONTEC central monitoring system in this patient monitor
    -- Powerful data management and storage capacity patient monitor
     
    Standard Configuration of ARI-6000 Patient Monitor:
    -- ECG, NIBP, Spo2
     
    ECG of ARI-6000 Patient Monitor:
    -- Lead type:5-lead
    -- Input: RA; LA; RL; LL; V
    -- Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
    -- Accuracy: ±2bpm or ±2%, whichever is greater
    -- Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
    -- S-T detection: YES, Arrhythmia analysis: YES
    -- Alarm: YES, audible and visual alarm, alarm events recallable
     
    NIBP of ARI-6000 Patient Monitor:
    -- Method: Oscillometry
    -- Operation modes: Manual/Automatic/STAT
    -- Measurement unit: mmHg/KPa selectable
    -- Measurement types: Systolic, Diastolic, Mean
    -- Over-pressure protection: YES
     
    Spo2 of ARI-6000 Patient Monitor:
    -- Measurement range: 0-100%
    -- Accuracy: ±2% (70~100%); 0~69% unspecified
     
    Optional parts of ARI-6000 Patient Monitor:
    -- RESP,2-TEMP,2-IBP,ETCO2,Network,Thermal Recorder

     


    Company: ARI Medical Equipment Co.,Ltd
  • Monitor Multi-parameter  BPM9000A
    Features:

    Multi-parameter monitor is used for inspecting the patients on body features such as ECG,NIBP, HR,SpO2,RESP,TEMP;

    Measuring synchronously 3-7 lead of ECG, HR, SpO2, RESP, TEMP, PR, NIBP and pulse conducting time etc;

    12.1'' TFT Big-screen, real-color, wide-visual-angle and high-brightness LCD display;

    Built-in rechargeable batteries with maintenance-free and high-capacity can work more than 2 hours without additional power supply;

    With the linked formed by network, bed-side machines and central multi-parameter monitor system, constituting the web of monitoring;

    Able to display trend data, and manual printing and alarm trigger printing functions available;

    Able to use together with high-frequency electrical cutter and defibrillator.

    Specifications:
    I .Safety level
    Class I anti-electroshock equipment, ECG(RESP), TEMP--Type CF, SPO2, NIBP--BF

    2. Power supply
    AC 100-250V , 50/60Hz, Pmax=60VA, FUSE 0.5A

    3. Display
    True color,12.1''  type LCD, resolution 640x480

    4. Signal interface
    External display interface: standard VGA

    External communication interface: RS-485

    External print interface: standard combining-port

    5. Recorder
    Recording width: 48mm

    Paper speed: 25mm/s

    Trace: 3 channel

    6. ECG specifications:
    Lead mode:12 leads (R, L, F, N, C1, C2, C3, C4, C5,C6)

    Lead selection: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6

    Waveform:12 channels

    Gain: ×0.5, ×1.0, ×2.0

    Modes: diagnosis, monitoring, operation

    Input impedance: >5MΩ

    CMRR: >90dB

    Electrode offset potential: ±300mV

    Leakage current :<30μA

    ECG signal range: ±10Mv (Vp-p)

    Frequency response (bandwidth): Diagnosis 0.05-100Hz

    Monitoring: 0.5-40Hz

    Operation: 1-20Hz

    Measurement range: 10-254bpm

    Resolution: 1bpm

    7. RESP specifications:
    Method: Impedance between RA-LA

    Input impedance: >2.5MΩ

    Bandwidth:0.3-2Hz

    Resp.rate:0-120rpm

    Measuring Range: 0-120rpm

    Resolution: 1bpm

    8. NIBP specifications:
    Method: oscillation

    Mode: manual, periodic, continuous

    Measuring interval in periodic mode: 3, 10, 45, 60 min

    Continuous mode:5 min

    Pulse rate range:40-240bpm

    Overpressure protection: adult 290 mmHg child 145 mmHg

    9. SPO2 specifications:
    Measuring range:0-100%

    Resolution: 1%

    Actualization interval: 1sec.

    Alarm delay: 10 sec.

    Pulse rate: measuring range 0-254bpm

    10. TEMP Specifications:
    Measuring range: 0-50℃

    Resolution: 0.1℃

    Actualization interval: 1sec.

    Average time constant :<10 sec.

    Packaging collocation:
    Packaging Dimension: 45cmx45cmx35cm  

    Gross weight:12kg

    Normative collocation: 220V power cable 1 pcs, BPM-9000 six-parameter, BPM-9000A six-parameter+ printer, BPM-9000B six-parameter+printer+CO2, BPM-9000C six-parameter+printer+single fetal monitor.
     


    Company: Shenzhen Bestman Instument Co., Ltd
  • Monitor Multi-parameter  BPM9000A
    Features:

    Multi-parameter monitor is used for inspecting the patients on body features such as ECG,NIBP, HR,SpO2,RESP,TEMP;

    Measuring synchronously 3-7 lead of ECG, HR, SpO2, RESP, TEMP, PR, NIBP and pulse conducting time etc;

    12.1'' TFT Big-screen, real-color, wide-visual-angle and high-brightness LCD display;

    Built-in rechargeable batteries with maintenance-free and high-capacity can work more than 2 hours without additional power supply;

    With the linked formed by network, bed-side machines and central multi-parameter monitor system, constituting the web of monitoring;

    Able to display trend data, and manual printing and alarm trigger printing functions available;

    Able to use together with high-frequency electrical cutter and defibrillator.

    Specifications:
    I .Safety level
    Class I anti-electroshock equipment, ECG(RESP), TEMP--Type CF, SPO2, NIBP--BF

    2. Power supply
    AC 100-250V , 50/60Hz, Pmax=60VA, FUSE 0.5A

    3. Display
    True color,12.1''  type LCD, resolution 640x480

    4. Signal interface
    External display interface: standard VGA

    External communication interface: RS-485

    External print interface: standard combining-port

    5. Recorder
    Recording width: 48mm

    Paper speed: 25mm/s

    Trace: 3 channel

    6. ECG specifications:
    Lead mode:12 leads (R, L, F, N, C1, C2, C3, C4, C5,C6)

    Lead selection: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6

    Waveform:12 channels

    Gain: ×0.5, ×1.0, ×2.0

    Modes: diagnosis, monitoring, operation

    Input impedance: >5MΩ

    CMRR: >90dB

    Electrode offset potential: ±300mV

    Leakage current :<30μA

    ECG signal range: ±10Mv (Vp-p)

    Frequency response (bandwidth): Diagnosis 0.05-100Hz

    Monitoring: 0.5-40Hz

    Operation: 1-20Hz

    Measurement range: 10-254bpm

    Resolution: 1bpm

    7. RESP specifications:
    Method: Impedance between RA-LA

    Input impedance: >2.5MΩ

    Bandwidth:0.3-2Hz

    Resp.rate:0-120rpm

    Measuring Range: 0-120rpm

    Resolution: 1bpm

    8. NIBP specifications:
    Method: oscillation

    Mode: manual, periodic, continuous

    Measuring interval in periodic mode: 3, 10, 45, 60 min

    Continuous mode:5 min

    Pulse rate range:40-240bpm

    Overpressure protection: adult 290 mmHg child 145 mmHg

    9. SPO2 specifications:
    Measuring range:0-100%

    Resolution: 1%

    Actualization interval: 1sec.

    Alarm delay: 10 sec.

    Pulse rate: measuring range 0-254bpm

    10. TEMP Specifications:
    Measuring range: 0-50℃

    Resolution: 0.1℃

    Actualization interval: 1sec.

    Average time constant :<10 sec.

    Packaging collocation:
    Packaging Dimension: 45cmx45cmx35cm  

    Gross weight:12kg

    Normative collocation: 220V power cable 1 pcs, BPM-9000 six-parameter, BPM-9000A six-parameter+ printer, BPM-9000B six-parameter+printer+CO2, BPM-9000C six-parameter+printer+single fetal monitor.
     


    Company: Shenzhen Bestman Instument Co., Ltd
  • Monitor Multi-parameter  BPM9500A

    Features:
    12.1'' TFT Big-screen, real-color, wide-visual-angle and high-brightness LCD display, Chinese-English language interface;

    Can monitor the main waveforms of standard synchronous 7-lead and 12-lead,analyze on ST segment to facilitate diagnosis for doctors, choose the source of three kinds of Heart Rate, have waveform-filling and 5-min cardiac electric replay function, measure synchronous many kinds of standard regular parameters, pulse conducting time and cuff pressure, and save the integrate patient information and review the monitoring-record;

    With the formed by network, bed-side machines and central multi-parameter monitor system, constituting the web of monitoring and trend-data display and 256 hours trend review;

    With standard six-parameter monitoring, adding single/double IBP, Et CO2(side stream),monitoring fetal function to provide accurate quickening and TOCO;

    With manual printing and alarm trigger printing functions available, and able to use together with high-frequency electrical cutter and defibrillator.

    Specifications:

    1.Safety level
    Class I anti-electroshock equipment, ECG(RESP), TEMP--Type CF, SPO2, NIBP--BF

    2. Power supply
    AC 100-250V , 50/60Hz, Pmax=60VA, FUSE 0.5A

    3. Display
    True color,12.1'' type LCD, resolution 640x480

    4. Signal interface
    External display interface: standard VGA

    External communication interface: RS-485

    External print interface: standard combining-port

    5. Recorder
    Recording width: 48mm

    Paper speed: 25mm/s

    Trace: 3 channel

    6. ECG specifications:
    Lead mode:12 leads (R,L, F, N, C1, C2, C3, C4, C5, C6)

    Lead selection: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6

    Waveform:12 channels

    Gain: ×0.5, ×1.0, ×2.0

    Modes: diagnosis, monitoring, operation

    Input impedance:>5MΩ

    CMRR: >90dB

    Electrode offset potential: ±300mV

    Leakage current :<30μA

    ECG signal range: ±10mV(Vp-p)

    Frequency response (bandwidth):diagnosis 0.05-100Hz

    Monitoring: 0.5-40Hz

    Operation: 1-20Hz

    Measurement range: 10-254bpm

    Resolution: 1bpm

    7. RESP specifications:
    Method: Impedance between RA-LA

    Input impedance: >2.5MΩ

    Bandwidth: 0.3-2Hz

    Resp rate: 0-120rpm

    Measuring Range: 0-120rpm

    Resolution: 1bpm
    8. NIBP specifications:
    Method: oscillation

    Mode: manual, periodic, continuous

    Measuring interval in periodic mode: 3, 10, 45, 60 min

    Continuous mode: 5 min

    Pulse rate range: 40-240bpm

    Overpressure protection: adult 290 mmHg child 145 mmHg

    9. SPO2 specifications:
    Measuring range: 0-100%

    Resolution: 1%

    Actualization interval: 1sec

    Alarm delay: 10 sec

    Pulse rate: measuring range: 0-254bpm

    10. TEMP Specifications:
    Measuring range: 0-50℃

    Resolution: 0.1℃

    Actualization interval: 1sec

    Average time constant: <10 sec

    Packaging collocation
    Packaging Dimension: 45cmx45cmx35cm

    Gross weight:12kg

    Normative collocation: 220V power cable 1pcs, BPM-9500 six-parameter, BPM-9500A six-parameter+ printer, BPM-9500B six-parameter+printer+EtCO2, BPM-9500C six-parameter+printer+single fetal monitor.
     

    Company: Shenzhen Bestman Instument Co., Ltd
  • Monitor Multi-parameter  BPM9500A

    Features:
    12.1'' TFT Big-screen, real-color, wide-visual-angle and high-brightness LCD display, Chinese-English language interface;

    Can monitor the main waveforms of standard synchronous 7-lead and 12-lead,analyze on ST segment to facilitate diagnosis for doctors, choose the source of three kinds of Heart Rate, have waveform-filling and 5-min cardiac electric replay function, measure synchronous many kinds of standard regular parameters, pulse conducting time and cuff pressure, and save the integrate patient information and review the monitoring-record;

    With the formed by network, bed-side machines and central multi-parameter monitor system, constituting the web of monitoring and trend-data display and 256 hours trend review;

    With standard six-parameter monitoring, adding single/double IBP, Et CO2(side stream),monitoring fetal function to provide accurate quickening and TOCO;

    With manual printing and alarm trigger printing functions available, and able to use together with high-frequency electrical cutter and defibrillator.

    Specifications:

    1.Safety level
    Class I anti-electroshock equipment, ECG(RESP), TEMP--Type CF, SPO2, NIBP--BF

    2. Power supply
    AC 100-250V , 50/60Hz, Pmax=60VA, FUSE 0.5A

    3. Display
    True color,12.1'' type LCD, resolution 640x480

    4. Signal interface
    External display interface: standard VGA

    External communication interface: RS-485

    External print interface: standard combining-port

    5. Recorder
    Recording width: 48mm

    Paper speed: 25mm/s

    Trace: 3 channel

    6. ECG specifications:
    Lead mode:12 leads (R,L, F, N, C1, C2, C3, C4, C5, C6)

    Lead selection: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6

    Waveform:12 channels

    Gain: ×0.5, ×1.0, ×2.0

    Modes: diagnosis, monitoring, operation

    Input impedance:>5MΩ

    CMRR: >90dB

    Electrode offset potential: ±300mV

    Leakage current :<30μA

    ECG signal range: ±10mV(Vp-p)

    Frequency response (bandwidth):diagnosis 0.05-100Hz

    Monitoring: 0.5-40Hz

    Operation: 1-20Hz

    Measurement range: 10-254bpm

    Resolution: 1bpm

    7. RESP specifications:
    Method: Impedance between RA-LA

    Input impedance: >2.5MΩ

    Bandwidth: 0.3-2Hz

    Resp rate: 0-120rpm

    Measuring Range: 0-120rpm

    Resolution: 1bpm
    8. NIBP specifications:
    Method: oscillation

    Mode: manual, periodic, continuous

    Measuring interval in periodic mode: 3, 10, 45, 60 min

    Continuous mode: 5 min

    Pulse rate range: 40-240bpm

    Overpressure protection: adult 290 mmHg child 145 mmHg

    9. SPO2 specifications:
    Measuring range: 0-100%

    Resolution: 1%

    Actualization interval: 1sec

    Alarm delay: 10 sec

    Pulse rate: measuring range: 0-254bpm

    10. TEMP Specifications:
    Measuring range: 0-50℃

    Resolution: 0.1℃

    Actualization interval: 1sec

    Average time constant: <10 sec

    Packaging collocation
    Packaging Dimension: 45cmx45cmx35cm

    Gross weight:12kg

    Normative collocation: 220V power cable 1pcs, BPM-9500 six-parameter, BPM-9500A six-parameter+ printer, BPM-9500B six-parameter+printer+EtCO2, BPM-9500C six-parameter+printer+single fetal monitor.
     

    Company: Shenzhen Bestman Instument Co., Ltd
  • ECG machines.patient monitor,Fetal Doppler,Pulse oximeter,auto-analyzer
     1. 6standard parameters: ECG, RESP, NIBP, SPO2, 1-TEMP, PR/HR.

    2. 12.1” high resolution color TFT LTD display.

    3. Real time S-T segment analysis, pace-maker detection and AR analysis.

    4. Multi-display selectable including standard, large font, trend coexist,
    Oxy CRG dynamic view and bed-to-bed view display.

    5. Indication of Incorrect manipulation and malfunction analysis.

    6. On-line help and Patient info input management.

    7. Multi-lead ECG waveforms display in phase.

    8. Large volume of tabular and graphic trends information storage and easy to recall.

    9. Capture dynamic waveforms.

    10. Efficient resistance to interference of defibrillator and HF knife.

    11. Up to 4 hours working capacity of built-in rechargeable battery.

    12. Networking capacity and TCP/IP networking platform.

    13. Option of IBP and EtCO2.

    Company: Shenzhen Spring Technology Industry Co.,Ltd
  • ECG machines.patient monitor,Fetal Doppler,Pulse oximeter,auto-analyzer
     1. 6standard parameters: ECG, RESP, NIBP, SPO2, 1-TEMP, PR/HR.

    2. 12.1” high resolution color TFT LTD display.

    3. Real time S-T segment analysis, pace-maker detection and AR analysis.

    4. Multi-display selectable including standard, large font, trend coexist,
    Oxy CRG dynamic view and bed-to-bed view display.

    5. Indication of Incorrect manipulation and malfunction analysis.

    6. On-line help and Patient info input management.

    7. Multi-lead ECG waveforms display in phase.

    8. Large volume of tabular and graphic trends information storage and easy to recall.

    9. Capture dynamic waveforms.

    10. Efficient resistance to interference of defibrillator and HF knife.

    11. Up to 4 hours working capacity of built-in rechargeable battery.

    12. Networking capacity and TCP/IP networking platform.

    13. Option of IBP and EtCO2.

    Company: Shenzhen Spring Technology Industry Co.,Ltd
  • IBP cable and transducer

    we have Abbott,Edward,Utah,and BD adapter cable,the product is compatible with HP/Philips,GE/Marquette,Spacelab,Datex ,Siemens,Mindray,CSI,Drager,Nihon Kohden and so on.

    Company: HK Greatmade Tech Ltd
Select to
Page 7 of 14    7 ......
Go to Page