Fetal Heart Monitor trade,Fetal Heart Monitor offer, Sell leads
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
Select to
Page 6 of 15
  • Fetal Heart Rate Detector BF-500A
    Features:
    Pocket Fetal Doppler mainly applies to detect the fetal heartbeat rate from the twelfth week;

    LCD can display FHR, synchronous FHR signal, battery indicator, volume of sound and alarm indicator accurately;

    Built-in rechargeable battery can work continuously more than 4 hours;

    Modem inside can dial up and transmit FHR signal to the monitor center through telephone line to carry out remote monitoring;

    Blue backlight LCD display for use conveniently at night;

    Automatic power off ( one minute), self-detect function and alarm function when FHR is out of the normal range or battery power is in shortage;

    Only 300g; can be carried conveniently with a gallus;

    Built-in speaker and collocated with earphone jack;

    2.0 MHz probe and easy to replace,optional 5.0MHz probe for blood stream.

    Specifications:
    Executive Standard: EN61266: 1995

    Ultrasonic frequency: 2.0 MHz±10%

    Ultrasonic intensity: ≤10mW/cm2

    Comprehensive Sensitivity: ≥90dB

    FHR range: 60--210bpm(±2bpm)

    FHR alarm range: ≤100bpm or  ≥160bpm

    Isptp: ≤0.1MPa

    Battery: 9.6VNi-MH rechargeable batteries

    Adapter input voltage: AC 110V±10% 60Hz / 220V±10% 50Hz

    Rechargeable battery input voltage(no load): DC 12V±1V

    Maximum audio output intensity: ≤0.5W

    Doppler frequency: 100--3000Hz

    Static continuous working time: ≥4h

    Automatic Dormancy time limit:1 minute

    Working temperature: 10-40℃

    Humidity: ≤80% 

    Atmospheric pressure: 86--106kPa

    Packaging collocation:
    Single Unit        Dimension: 20.7cm x 16.8cm x 7.1cm     Gross Weight:0.85kg

    20 pcs/carton   Dimension: 43cm x 35cm x 40cm             Gross Weight:18kg

    Normative collocation: charger, earphone, gel, small bag, gallus, operation manual, approval certification, warranty card
     


    Company: Shenzhen Bestman Instument Co., Ltd
  • Fetal Heart Rate Detector BF-500A
    Features:
    Pocket Fetal Doppler mainly applies to detect the fetal heartbeat rate from the twelfth week;

    LCD can display FHR, synchronous FHR signal, battery indicator, volume of sound and alarm indicator accurately;

    Built-in rechargeable battery can work continuously more than 4 hours;

    Modem inside can dial up and transmit FHR signal to the monitor center through telephone line to carry out remote monitoring;

    Blue backlight LCD display for use conveniently at night;

    Automatic power off ( one minute), self-detect function and alarm function when FHR is out of the normal range or battery power is in shortage;

    Only 300g; can be carried conveniently with a gallus;

    Built-in speaker and collocated with earphone jack;

    2.0 MHz probe and easy to replace,optional 5.0MHz probe for blood stream.

    Specifications:
    Executive Standard: EN61266: 1995

    Ultrasonic frequency: 2.0 MHz±10%

    Ultrasonic intensity: ≤10mW/cm2

    Comprehensive Sensitivity: ≥90dB

    FHR range: 60--210bpm(±2bpm)

    FHR alarm range: ≤100bpm or  ≥160bpm

    Isptp: ≤0.1MPa

    Battery: 9.6VNi-MH rechargeable batteries

    Adapter input voltage: AC 110V±10% 60Hz / 220V±10% 50Hz

    Rechargeable battery input voltage(no load): DC 12V±1V

    Maximum audio output intensity: ≤0.5W

    Doppler frequency: 100--3000Hz

    Static continuous working time: ≥4h

    Automatic Dormancy time limit:1 minute

    Working temperature: 10-40℃

    Humidity: ≤80% 

    Atmospheric pressure: 86--106kPa

    Packaging collocation:
    Single Unit        Dimension: 20.7cm x 16.8cm x 7.1cm     Gross Weight:0.85kg

    20 pcs/carton   Dimension: 43cm x 35cm x 40cm             Gross Weight:18kg

    Normative collocation: charger, earphone, gel, small bag, gallus, operation manual, approval certification, warranty card
     


    Company: Shenzhen Bestman Instument Co., Ltd
  • Fetal Heart Rate Detector BF-500B
    Features:
    Pocket Fetal Doppler mainly applies to detect the fetal heartbeat rate from the twelfth week;

    LCD can display FHR, synchronous FHR signal, battery indicator, volume of sound and alarm indicator accurately;

    Built-in rechargeable battery can work continuously more than 4 hours;

    Blue backlight LCD display for use conveniently at night;

    Automatic power off ( one minute), self-detect function, Alarm function when FHR is out of the normal range or battery power is in shortage;

    Only 270g, Can be carried conveniently with a gallus;

    Built-in speaker and collocated with earphone jack;

    2.0 MHz probe and easy to replace, optional 5.0MHz probe for blood stream.

    Specification:
    Executive Standard: EN61266: 1995

    Ultrasonic frequency: 2.0 MHz±10%

    Ultrasonic intensity: ≤10mW/cm2

    Comprehensive Sensitivity: ≥90dB

    FHR range: 60--210bpm(±2bpm)

    FHR alarm range: ≤100bpm or  ≥160bpm

    Isptp: ≤0.1MPa

    Battery: 9.6VNi-MH rechargeable batteries

    Adapter input voltage: AC 110V±10% 60Hz / 220V±10% 50Hz

    Rechargeable battery input voltage(no load): DC 12V±1V

    Maximum audio output intensity: ≤0.5W

    Doppler frequency: 100--3000Hz

    Static continuous working time: ≥4h

    Automatic Dormancy time limit:1 minute

    Working temperature: 10-40℃

    Humidity: ≤80% 

    Atmospheric pressure: 86--106kPa

    Packaging collocation:
    Single Unit        Dimension: 20.7cm x 16.8cm x 7.1cm    Gross Weight:0.85kg

    20 pcs/carton   Dimension: 43cm x 35cm x 40cm            Gross Weight:18kg

    Normative collocation: charger, earphone, gel, small bag, gallus, operation manual, approval certification, warranty card


    Company: Shenzhen Bestman Instument Co., Ltd
  • Fetal Heart Rate Detector BF-500B
    Features:
    Pocket Fetal Doppler mainly applies to detect the fetal heartbeat rate from the twelfth week;

    LCD can display FHR, synchronous FHR signal, battery indicator, volume of sound and alarm indicator accurately;

    Built-in rechargeable battery can work continuously more than 4 hours;

    Blue backlight LCD display for use conveniently at night;

    Automatic power off ( one minute), self-detect function, Alarm function when FHR is out of the normal range or battery power is in shortage;

    Only 270g, Can be carried conveniently with a gallus;

    Built-in speaker and collocated with earphone jack;

    2.0 MHz probe and easy to replace, optional 5.0MHz probe for blood stream.

    Specification:
    Executive Standard: EN61266: 1995

    Ultrasonic frequency: 2.0 MHz±10%

    Ultrasonic intensity: ≤10mW/cm2

    Comprehensive Sensitivity: ≥90dB

    FHR range: 60--210bpm(±2bpm)

    FHR alarm range: ≤100bpm or  ≥160bpm

    Isptp: ≤0.1MPa

    Battery: 9.6VNi-MH rechargeable batteries

    Adapter input voltage: AC 110V±10% 60Hz / 220V±10% 50Hz

    Rechargeable battery input voltage(no load): DC 12V±1V

    Maximum audio output intensity: ≤0.5W

    Doppler frequency: 100--3000Hz

    Static continuous working time: ≥4h

    Automatic Dormancy time limit:1 minute

    Working temperature: 10-40℃

    Humidity: ≤80% 

    Atmospheric pressure: 86--106kPa

    Packaging collocation:
    Single Unit        Dimension: 20.7cm x 16.8cm x 7.1cm    Gross Weight:0.85kg

    20 pcs/carton   Dimension: 43cm x 35cm x 40cm            Gross Weight:18kg

    Normative collocation: charger, earphone, gel, small bag, gallus, operation manual, approval certification, warranty card


    Company: Shenzhen Bestman Instument Co., Ltd
  • Fetal Heart Rate Detector BF-530
    Feature:

    Pocket Fetal Doppler mainly applies to detect the fetal heartbeat rate from the twelfth week;

    LCD can display FHR data and heart rate graphics, battery indicator, volume of sound and alarm indicator;

    Built-in rechargeable battery can work continuously more than 4 hours;

    White backlight LCD display for use conveniently at night;

    Automatic power off (one minute), self-detect function and alarm function when FHR is out of the normal range or battery power is in shortage;

    Only 270g, can be carried with conveniently with an earphone, gllus and portable handbag;

    Built-in speaker, collocate with earphone jack;

    1.0MHz probe,optional 5.0MHz probe for blood stream.

    Specifications:
    Executive standard: EN61266: 1995

    Ultrasonic frequency: 1.0MHz±10%

    Working mode: Pulse Ultrasonic Doppler

    Ultrasonic intensity: ≤10mW/cm2

    Comprehensive Sensitivity: ≥90dB

    FHR range: 60--210bpm(±2bpm)

    Isptp: ≤0.1MPa

    Battery: 9.6VNi-MH rechargeable batteries

    Adapter input voltage: AC 100--240V 50Hz/60Hz

    Rechargeable battery input voltage(no load): DC 5V/1A

    Maximum audio output intensity: ≤0.5W

    Doppler frequency: 100--3000Hz

    Static continuous working time: ≥4h

    Automatic Dormancy time limit:1 minute

    Working temperature: 10-40℃

    Humidity: ≤80%

    Atmospheric pressure: 86--106kPa

    Packaging collocation:
    Single Unit     Dimension: 23.5cm x 22cm x 10cm        Gross Weight: 0.5kg

    6 pcs/carton   Dimension: 49cm x 25cm x 32cm           Gross Weight: 4kg

    Normative collocation: charger, gel, small bag, gallus, operation manual, approval certification, warranty card
     


    Company: Shenzhen Bestman Instument Co., Ltd
  • Fetal Heart Rate Detector BF-530
    Feature:

    Pocket Fetal Doppler mainly applies to detect the fetal heartbeat rate from the twelfth week;

    LCD can display FHR data and heart rate graphics, battery indicator, volume of sound and alarm indicator;

    Built-in rechargeable battery can work continuously more than 4 hours;

    White backlight LCD display for use conveniently at night;

    Automatic power off (one minute), self-detect function and alarm function when FHR is out of the normal range or battery power is in shortage;

    Only 270g, can be carried with conveniently with an earphone, gllus and portable handbag;

    Built-in speaker, collocate with earphone jack;

    1.0MHz probe,optional 5.0MHz probe for blood stream.

    Specifications:
    Executive standard: EN61266: 1995

    Ultrasonic frequency: 1.0MHz±10%

    Working mode: Pulse Ultrasonic Doppler

    Ultrasonic intensity: ≤10mW/cm2

    Comprehensive Sensitivity: ≥90dB

    FHR range: 60--210bpm(±2bpm)

    Isptp: ≤0.1MPa

    Battery: 9.6VNi-MH rechargeable batteries

    Adapter input voltage: AC 100--240V 50Hz/60Hz

    Rechargeable battery input voltage(no load): DC 5V/1A

    Maximum audio output intensity: ≤0.5W

    Doppler frequency: 100--3000Hz

    Static continuous working time: ≥4h

    Automatic Dormancy time limit:1 minute

    Working temperature: 10-40℃

    Humidity: ≤80%

    Atmospheric pressure: 86--106kPa

    Packaging collocation:
    Single Unit     Dimension: 23.5cm x 22cm x 10cm        Gross Weight: 0.5kg

    6 pcs/carton   Dimension: 49cm x 25cm x 32cm           Gross Weight: 4kg

    Normative collocation: charger, gel, small bag, gallus, operation manual, approval certification, warranty card
     


    Company: Shenzhen Bestman Instument Co., Ltd
  • Fetal Heart Rate Detector BF-500+

    Features:
    Pocket Fetal Doppler mainly applies to detect the fetal heartbeat rate from the twelfth week;

    LCD can display FHR accurately;

    Built-in rechargeable battery can work continuously more than 5 hours;

    Only 220g, can be carried conveniently with a gallus;

    Alarm function when FHR is out of the normal range or battery power is in shortage;

    Built-in speaker and collocated with earphone jack;

    2.5MHz probe and easy to replace.

    Specifications:
    Executive Standard: EN61266: 1995

    Ultrasonic frequency: 2.5MHz±10%

    Ultrasonic intensity: ≤10mW/cm2

    Comprehensive Sensitivity: ≥90dB

    FHR range: 60-210bpm(±2bpm)

    FHR alarm range: ≤100bpm or  ≥160bpm

    Isptp: ≤0.1MPa

    Battery: 9.6VNi-MH rechargeable batteries

    Adapter input voltage: AC 110V±10% 60Hz / 220V±10% 50Hz

    Rechargeable battery input voltage(no load): DC 12V±1V

    Maximum audio output intensity: ≤1W

    Doppler frequency: 100--3000Hz

    Static continuous working time: ≥5h

    Working temperature: 10-40℃

    Humidity: ≤80%

    Atmospheric pressure: 86--106kPa

    Packaging collocation:
    Single Unit        Dimension: 20cm x 16.5cm x 6.5cm           Gross Weight:0.65kg

    20 pcs/carton  Dimension: 40.5cm x 33.5cm x 33.5cm       Gross Weight:13.5kg

    Normative collocation: charger, gallus, operation manual, approval certification, warranty card


    Company: Shenzhen Bestman Instument Co., Ltd
  • Fetal Heart Rate Detector BF-500+

    Features:
    Pocket Fetal Doppler mainly applies to detect the fetal heartbeat rate from the twelfth week;

    LCD can display FHR accurately;

    Built-in rechargeable battery can work continuously more than 5 hours;

    Only 220g, can be carried conveniently with a gallus;

    Alarm function when FHR is out of the normal range or battery power is in shortage;

    Built-in speaker and collocated with earphone jack;

    2.5MHz probe and easy to replace.

    Specifications:
    Executive Standard: EN61266: 1995

    Ultrasonic frequency: 2.5MHz±10%

    Ultrasonic intensity: ≤10mW/cm2

    Comprehensive Sensitivity: ≥90dB

    FHR range: 60-210bpm(±2bpm)

    FHR alarm range: ≤100bpm or  ≥160bpm

    Isptp: ≤0.1MPa

    Battery: 9.6VNi-MH rechargeable batteries

    Adapter input voltage: AC 110V±10% 60Hz / 220V±10% 50Hz

    Rechargeable battery input voltage(no load): DC 12V±1V

    Maximum audio output intensity: ≤1W

    Doppler frequency: 100--3000Hz

    Static continuous working time: ≥5h

    Working temperature: 10-40℃

    Humidity: ≤80%

    Atmospheric pressure: 86--106kPa

    Packaging collocation:
    Single Unit        Dimension: 20cm x 16.5cm x 6.5cm           Gross Weight:0.65kg

    20 pcs/carton  Dimension: 40.5cm x 33.5cm x 33.5cm       Gross Weight:13.5kg

    Normative collocation: charger, gallus, operation manual, approval certification, warranty card


    Company: Shenzhen Bestman Instument Co., Ltd
  • Fetal Monitor BFM-700+ TFT
    Features:

    BFM-700+ is fetal monitor with USB for twin.

    5.7 inches TFT LCD displays US and UC data with monitoring trace curve;

    FHR collects signal indication, alarm indication for abnormal FHR, fetal movement indication, and can freeze monitoring status;

    Can set the time limit (0-99 minutes), automatically entering dormant state if no signal input;

    Store monitoring data for 24 hours, with replay function;

    Coding keyboard adjusts all parameters setting of the unit, convenient to use;

    Adopt 832 thermal linear array printer, store the data and print rapidly; and printing width is 112mm;

    The printer parameters can be adjusted according to user needs, including printing paper speed, trace line thickness, signal sampling rate, upper and lower alarming limit, real time, and date;

    Set-up data and parameters can be automatically saved after power off;

    The monitoring data can be conveyed to exterior computer through RS-232 or USB port;

    Trolly (adjustable) for option, convenient to move and operate.


    Specifications:
    1.  US:
    Transducer :  9 crystals, wide wave beam
    Working mode: Pulsed ultrasound Doppler
    Ultrasonic frequency: 1.0MHz±10%
    Measuring range:    50-240 BPM
    Alarm range:  Up: 55-240 BPM  Adjustable continuously within range
                           Low: 50-235 BPM  Adjustable continuously within range

    2.  TOCO:
    Display range: 0-100units  (non-linear error: ≤±10%)

    3.  PC PORT:
    Edition USB 1.1 or USB 2.0; RS-232

    4. THERMAL RECORDER:
    Paper width : 112 ± 2mm ;effective record width : 105 ± 2mm;  Paper length : 15m
    Recorder density :  US:  27 BPM/ CM ;   UC:  40 BPM / CM
    Printing speed (adjustable):  1 cm/min, 2 cm/min, 3 cm/min

    5. POWER and BATTERY:
    Battery: 16.8V Ni-MH rechargeable batteries group;  AC 220 /110 V ;  Consume power: ≤ 50 W
    Continuous working time in static condition: ≥ 2 hours

    6. ENVIROANMENT REQUIREMENT:
    Working Temperature: +5 ℃-40 ℃  Humidity: ≤80%  Atmospheric pressure: 86 kPa—106 kPa

    7.  ACCESSORIES:
    Model BFM-700:  monitoring probe  (1.0 MHz)  1 pcs
    Model BFM-700+: monitoring probe  (1.0 MHz)  2 pcs
    UC probe ; event marker ; power switch ; cable ; 250 ml gel ; operation manual ;  warranty card ; approval certification , each 1 pcs
    Printing paper: 2 pcs


    Packaging collocation:
    Single Unit   Suitcase Package Dimension: 45cmx22cmx42cm         Gross weight: 7.5kg

    Single Unit   Paper carton Package Dimension: 48cmx24cmx32cm     Gross weight: 6kg

    Normative collocation: 1.0MHz probe, TOCO probe, remote Marker, switch power, cable, 250ml gel, operation manual, warranty card, approval certification, printing paper.


    Trolly ( Option):
    Model:BT-101M
    Function:Fix BFM-700 series fetal / maternal monitor
    Material:Stainless steel   Gross weight : 12 kg   Net weight: 10 kg
    Maximal load:15 kg  Height: 1200 mm  Base diameter:¢ 650  mm    


    Company: Shenzhen Bestman Instument Co., Ltd
  • Fetal Monitor BFM-700+ TFT
    Features:

    BFM-700+ is fetal monitor with USB for twin.

    5.7 inches TFT LCD displays US and UC data with monitoring trace curve;

    FHR collects signal indication, alarm indication for abnormal FHR, fetal movement indication, and can freeze monitoring status;

    Can set the time limit (0-99 minutes), automatically entering dormant state if no signal input;

    Store monitoring data for 24 hours, with replay function;

    Coding keyboard adjusts all parameters setting of the unit, convenient to use;

    Adopt 832 thermal linear array printer, store the data and print rapidly; and printing width is 112mm;

    The printer parameters can be adjusted according to user needs, including printing paper speed, trace line thickness, signal sampling rate, upper and lower alarming limit, real time, and date;

    Set-up data and parameters can be automatically saved after power off;

    The monitoring data can be conveyed to exterior computer through RS-232 or USB port;

    Trolly (adjustable) for option, convenient to move and operate.


    Specifications:
    1.  US:
    Transducer :  9 crystals, wide wave beam
    Working mode: Pulsed ultrasound Doppler
    Ultrasonic frequency: 1.0MHz±10%
    Measuring range:    50-240 BPM
    Alarm range:  Up: 55-240 BPM  Adjustable continuously within range
                           Low: 50-235 BPM  Adjustable continuously within range

    2.  TOCO:
    Display range: 0-100units  (non-linear error: ≤±10%)

    3.  PC PORT:
    Edition USB 1.1 or USB 2.0; RS-232

    4. THERMAL RECORDER:
    Paper width : 112 ± 2mm ;effective record width : 105 ± 2mm;  Paper length : 15m
    Recorder density :  US:  27 BPM/ CM ;   UC:  40 BPM / CM
    Printing speed (adjustable):  1 cm/min, 2 cm/min, 3 cm/min

    5. POWER and BATTERY:
    Battery: 16.8V Ni-MH rechargeable batteries group;  AC 220 /110 V ;  Consume power: ≤ 50 W
    Continuous working time in static condition: ≥ 2 hours

    6. ENVIROANMENT REQUIREMENT:
    Working Temperature: +5 ℃-40 ℃  Humidity: ≤80%  Atmospheric pressure: 86 kPa—106 kPa

    7.  ACCESSORIES:
    Model BFM-700:  monitoring probe  (1.0 MHz)  1 pcs
    Model BFM-700+: monitoring probe  (1.0 MHz)  2 pcs
    UC probe ; event marker ; power switch ; cable ; 250 ml gel ; operation manual ;  warranty card ; approval certification , each 1 pcs
    Printing paper: 2 pcs


    Packaging collocation:
    Single Unit   Suitcase Package Dimension: 45cmx22cmx42cm         Gross weight: 7.5kg

    Single Unit   Paper carton Package Dimension: 48cmx24cmx32cm     Gross weight: 6kg

    Normative collocation: 1.0MHz probe, TOCO probe, remote Marker, switch power, cable, 250ml gel, operation manual, warranty card, approval certification, printing paper.


    Trolly ( Option):
    Model:BT-101M
    Function:Fix BFM-700 series fetal / maternal monitor
    Material:Stainless steel   Gross weight : 12 kg   Net weight: 10 kg
    Maximal load:15 kg  Height: 1200 mm  Base diameter:¢ 650  mm    