  • Infant Incubator (B-2000)

    SPECIFICATIONS:
    Model: B-2000
    POWER
    Power Requirements: AC220V 10%, 50Hz 2%
    Power Input: ≤450VA
    Refer to IEC60601-1, this equipment belongs to Class I, Type B. Its operation is Continuous.
    ALARM
    Power Alarm
    Power Failure: Activates if primary power to the Incubator
    Fails or the power wire is accidentally
    Disconnected from the wall receptacle.

    Fan Alarm
    Fan Failure: Activates if Fan motor malfunctions. Sensor Alarm
    Air Sensor Failure: Air Sensor malfunction, refer unit to service.
    Sensor Out of Position: Activated when Sensor is not in correct position To perform calibration or continue operation.
    Skin Sensor Disconnected: Activated during Skin Control Mode when Skin Sensor is disconnected from Temperature Controller. Skin Sensor Failure: Activated when Skin Sensor malfunctions.
    Deviation Alarm High Air Temperature: Activated if displayed Air Temperature is 1.5 centigrade above set point
    Low Air Temperature: Activated if displayed Air Temperature 2.5centigrade below set point

    Skin Temperature: Activated if displayed Skin Temperature is 1.0 centigrade above set point
    Low Skin Temperature: Activated if displayed Skin Temperature is 1.0Over Temperature Alarm
    Over Air Temperature: Activated when displayed Air TemperatureWas approach 38centigrade for set temperature ≤37centigrade, Or approach 40centigrade for set temperature >37centigrade in Air Mode.

    Over Skin Temperature: Activated when displayed Skin Temperature was approach 38centigrade for set temperature ≤37centigrade, Or approach 39centigrade for set temperature >37centigrade in Skin Mode. System Alarm
    System Failure: Activated if Temperature Control System malfunctions.

    TEMPERATURE CONTROLRANGEAND CORRELATIVE SPECIFICATIONS
    Air Temperature: 20centigrade ~37centigrade, for set temperature ≤37centigrade
    37centigrade ~39centigrade, for set temperature >37centigrade
    Skin Temperature: 20centigrade ~37centigrade, for set temperature ≤37centigrade
    37centigrade~38centigrade, for set temperature >37centigrade
    Temperature Rise Time: ≤30min
    Temperature Variability: 0.5centigrade
    Temperature Uniformity: ≤ 1 centigrade
    Skin Sensor Precision: ≤0.3centigrade
    ENVIRONMENT REQUIREMENT

    Environment Temperature
    Operation Temperature Range+20centigrade ~+30centigrade
    Store Temperature Range -40centigrade ~+70centigrade
    Environment Humidity
    Operation Humidity Range: 30%~75%
    Store Humidity Range: ≤80%
    Atmospheric Pressure Range: 500hPa~1060hPa
    OTHER SPECIFICATION
    Noise Level Within Hood Environment ≤55dB(Environment noise below 45dB Carbon Dioxide (CO2) Level within the Hood Less than 0.5% when a mixture of CO2

    In air is delivered at 750ml/min
    At point 10cm above the center of the mattress.
    Air Velocit y Over Mattress less than: 0.35m/s
    Infant Bed Max Load: 10kg
    Transfusion Shelf Max Load: 2kg
    Shelf Max Load:
    Cabinet Max Load: 6kg


    Company: China Shikang Medical Equipment Group Limited
  • Infant Radiant Warmer (BNT-2000B )

    BNT-2000B Infant Radiant Warmer

    STANDARD COMPOSITION

    Temperature Control Mode: pre-heating control, servo control & manual control;
    Instant Parameter Display: set temp, skin temp, heat power rate;
    Built-in APGAR Timer and >37 preset function
    Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
    Tilting Bed with Rotary Radiant Head;
    X-ray Cassette Tray under infant bed, examination light of high illuminance;
    Use anti-blast quartz infrared tube as radiant heating source;
    With phototherapy unit;
    With two oxygen cylinders;
    With Suction, with neonate resuscitation.

     


    Company: China Shikang Medical Equipment Group Limited
  • Infant Radiant Warmer (BNT-2000B )

    BNT-2000B Infant Radiant Warmer

    STANDARD COMPOSITION

    Temperature Control Mode: pre-heating control, servo control & manual control;
    Instant Parameter Display: set temp, skin temp, heat power rate;
    Built-in APGAR Timer and >37 preset function
    Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
    Tilting Bed with Rotary Radiant Head;
    X-ray Cassette Tray under infant bed, examination light of high illuminance;
    Use anti-blast quartz infrared tube as radiant heating source;
    With phototherapy unit;
    With two oxygen cylinders;
    With Suction, with neonate resuscitation.

     


    Company: China Shikang Medical Equipment Group Limited
  • Infant Phototherapy Unit

    B-400 Infant Phototherapy Unit

    STANDARD COMPOSITION:


     Use LED light as lighting source, LED digital timer, display therapy time & total time

     

     

    TECHNICAL SPECIFICATION:


    POWER
    Model B-400-1E.........................................................................110 / 120 Vac, 50Hz / 60Hz
    Model B-400-2E................................................................................220 / 240Vac, 50Hz / 60Hz
    Input power...............................................................................................................≤50VA
    Accord with IEC 60601-1 standard, this device is in class I, continuous handling.
    Ebi in effective area surface.....................................................................................500μW/cm2
    Ebi max in effective area surface..............................................................................650μW/cm2
    Ebi average in effective area surface...................................................................................500μW/cm2
    Uniformity of Ebi...............................................................>0.4
              
    Infrared radiation in effective area....................................<1mW/cm2(760nm<λ≤1400nm=
    Ultraviolet radiation in effective area................<1.0×10-5mW/cm2 (180nm<λ≤400nm=
    Time display accuracy............................................................................................2h±1min
    Operate noise........................................≤50dB(A)
    ambit noise is lower than 40dB(A)
    ENVIRONMENT CONDITION
    Environment temperature
    Operate temperature

     


    Company: China Shikang Medical Equipment Group Limited
  • Infant Phototherapy Unit

    B-400 Infant Phototherapy Unit

    STANDARD COMPOSITION:


     Use LED light as lighting source, LED digital timer, display therapy time & total time

     

     

    TECHNICAL SPECIFICATION:


    POWER
    Model B-400-1E.........................................................................110 / 120 Vac, 50Hz / 60Hz
    Model B-400-2E................................................................................220 / 240Vac, 50Hz / 60Hz
    Input power...............................................................................................................≤50VA
    Accord with IEC 60601-1 standard, this device is in class I, continuous handling.
    Ebi in effective area surface.....................................................................................500μW/cm2
    Ebi max in effective area surface..............................................................................650μW/cm2
    Ebi average in effective area surface...................................................................................500μW/cm2
    Uniformity of Ebi...............................................................>0.4
              
    Infrared radiation in effective area....................................<1mW/cm2(760nm<λ≤1400nm=
    Ultraviolet radiation in effective area................<1.0×10-5mW/cm2 (180nm<λ≤400nm=
    Time display accuracy............................................................................................2h±1min
    Operate noise........................................≤50dB(A)
    ambit noise is lower than 40dB(A)
    ENVIRONMENT CONDITION
    Environment temperature
    Operate temperature

     


    Company: China Shikang Medical Equipment Group Limited
  • Infant Phototherapy Unit (B-100)

    STANDARD COMPOSITION:
    ● Single-side & five blue lights
    ● LED Digital Timer, display therapy time & total time
    ● Lifting & Mobile Stand, radiant head rotating by angle of 30°/ 60° /90°

     


    Company: China Shikang Medical Equipment Group Limited
  • Infant Phototherapy Unit (B-100)

    STANDARD COMPOSITION:
    ● Single-side & five blue lights
    ● LED Digital Timer, display therapy time & total time
    ● Lifting & Mobile Stand, radiant head rotating by angle of 30°/ 60° /90°

     


    Company: China Shikang Medical Equipment Group Limited
  • Infant Phototherapy Unit (B-200)

    STANDARD COMPOSITION:
    ● Single-side & LED lights;
    ● LED Digital Timer, display therapy time & total time;
    ● Top-put type applicable for any model of incubator.
     

     


    Company: China Shikang Medical Equipment Group Limited
  • Infant Phototherapy Unit (B-200)

    STANDARD COMPOSITION:
    ● Single-side & LED lights;
    ● LED Digital Timer, display therapy time & total time;
    ● Top-put type applicable for any model of incubator.
     

     


    Company: China Shikang Medical Equipment Group Limited
  • Infant Incubator (B-800)

    STANDARD COMPOSITION:
    ● Servo Control Mode: air temp;
    ● Instant Parameter Displaying: set temp, air temp, heat power rate;
    ● Audible & Visual Alarms: power failure, sensor failure, higher/lower temp, air temperature override, fan failure;
    ● Power failure reset memory and self-test function;
    ● Hood with dual slope: 4 hand-ports.


    Company: China Shikang Medical Equipment Group Limited