ECG Machine trade,ECG Machine offer, Sell leads
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
Select to
Page 3 of 13
  • Eledtrocardiograph-JPD-1106
    Eledtrocardiograph-JPD-1106

    Features:

    1. Light in weight, compact in size
    2. Three kinds of operation mode: Automatic, Manual, Analysis

    3. Standard lead mode or European lead mode available
    4. Automatic measurement and interpretation

    5. Detection and alarm of lead-off, No paper or no battery
    6. Built-in ECG simulator, Built-in rechargeable lithium battery with high capacity

    7. Automatic adjustment of baseline for optional recording
    8. RS 232 communication interface for linking to special network, PC, or setting up of ECG database, option blue-tooth interface

    9. Bulit-in help function: Electrode positioning, ECG basic knowledge, common trouble-shooting, etc.
    10. Clinical information such as patient ID, name, sex, age, height, weight, drugs and hospital name can be input( Available in Class G machine)

    11. Case storage function: 15cases can be saved in the machine or as much as 150cases in a SD card. Saved ECG waveforms can be cine-looped, printed out or transferred to PC.

    Specification:

    Safety standard: IEC class I, type CF
    Acquisition Mode: 12lead acquisition simultaneously
    Input Circuit: Floating, protection against defibrillator and pacemaker
    A/D converter: 24bit
    Time constant: ≥3.2/s
    Frequency response: 0.05-165HZ
    Sensitivity: 2.5, 5, 10, 20mm/mv, auto
    Input impedance:≥50MΩ
    Input circuit current: ≤50nA
    Calibration voltage: 1mV±2%
    Noise level: <15μVp-p
    Filter: EMG filter: 35Hz-45Hz (-3dB)
    ADS filter: Auto (0.15-0.5Hz)
    HUM filter: 50Hz/60Hz (-20dB)
    CMRR: >100dB
    Patient current leakage: <10μA
    Paper speed: 6.25/12.5/ 25/ 50mm/s
    Recording paper: 112MM (width), 20m/30m(length), roll/Z-fold
    Power requirement:
    AC220V, 50HZ/110V,60HZ;
    85v-265v (option)
    DC: 14.4v/2Ah
    Bulit-in rechargeable lithium battery
    Dimension: 345mm*300mm*80mm; 400mm*180mm*355mm (Carton)
    Net weight: 2.5kg; Gross weight: 4.5kg


    Company: Shenzhen Jumper Meditech Co., Ltd
  • Eledtrocardiograph-JPD-1112
    Eledtrocardiograph-JPD-1112
    Features:
    1. Simultaneous aciquisition of 12-lead ECG data, real-time recording and printing of 12-channel ECG waveform
    2. Graphic display of 12-lead ECG waveform
    3. Built-in analysis software of age which assurate analysis result
    4. Auto-measurement, auto-interpretation, waveform playback and storage of ECG data
    5. RS 232 and USB interface cope with data-share or remote data management requirement
    6. Option wireless function makes more convenient communication with PC
    7. User friendly operation system contributed by built-in help function
    8. Literal and graphic operation interface
    9. Powerful filter to minimize interference
    10. Heart rate measurement and pace-maker protection circuit
    11. Multi-printing formats: Manual/automatic, standard 12channel, 3 channel plus 3 rhythm lead, 6 channel, 6 channel plus rhythm lead, 60s anaysis of arrhythmia, R-R histogram, trend graph
    12. AC, DC or built-in lithium battery power supply, alarm of battery weak and lead-off

    13. Comfort and durability contributed by silicon gel keypad
    14. Tremendous ECG data can be saved in built-in SD card

    Specification:

    Screen size: Class L 5.7 inch; Class M 7.0 inches
    Input Circuit: Floating, protection against defibrillator and pacemaker
    Lead: Standard 12 lead
    A/D converter: 12bit
    Time constant: >3.2/s
    Frequency response: 0.05-165HZ (-3dB)
    Measurement: Heart rate, PR Int., Vent. Rate, P/QPS/T Axis
    Sensitivity: 2.5, 5, 10, 20mm/mv (±2%), auto
    Input impedance:≥50MΩ
    Input circuit current: ≤50nA
    Calibration voltage: 1mV±2%
    Noise level: <15μVp-p
    Patient data: Date, time, ID, name, gender, age, height, weight, blood pressure, etc
    CMRR: >100dB
    System Data: Sensitivity, paper speed, filter on/off, hospital name, etc
    Paper speed: 6.25/12.5/ 25/ 50mm/s (±3%)
    Print-out: waveform, waveform+measurement report, or waveform+measurement report+anaysis report
    Power requirement:
    AC100V, 50HZ/240V,
    60HZ; 85v-265v (option)
    DC: 19v/3.5A; Battery: 14.4v/4400mAh bulit-in rechargeable lithium battery, over 2hours working time
    Dimension: 345mm*300mm*80mm; 400mm*180mm*355mm (Carton)
    Net weight: 3.5kg; Gross weight: 5.5kg
    Carton size: 216mm*30m roll paper, or 216mm*100mm*200pages Z-fold paper


    Company: Shenzhen Jumper Meditech Co., Ltd
  • Eledtrocardiograph-JPD-1101
    Features:

    1. Light in weight, compact in size
    2. Three kinds of operation mode: Automatic, Manual, Analysis
    3. Standard lead mode or European lead mode available
    4. Detection and alarm of lead-off, No paper or no battery
    Built-in ECG simulator
    6. Automatic adjustment of baseline for optional recording
    7. RS 232 communication interface for linking to special network or setting up of ECG database
    8. Optional blue tooth interface
    9. Automatic measurement, optional interpretation function in Class G machine
    10. Display of ECG waveform on LCD (Available in Class C and G machine)
    11. Bulit-in help function: Electrode positioning, ECG basic knowledge, dispose of common breakdown etc. (Available in Class G machine)
    12. Clinical information such as patient ID, name, sex, age, height, weight, drugs and hospital name can be input( Available in Class G machine)
    13. Case storage function: 15cases can be saved in the machine or as much as 150cases in a SD card. Saved ECG waveforms can be cine-looped, printed out or transferred to PC. (Available in Class G machine)

    Specification

    Safety standard: IEC class I, type CF
    Acquisition Mode: 12lead acquisition simultaneously
    Input Circuit: Floating, protection against defibrillator and pacemaker
    A/D converter: 18bit
    Frequency response: 0.05-150HZ
    Sensitivity: 2.5, 5, 10, 20mm/mv, auto
    Input impedance:≥50MΩ


    Company: Shenzhen Jumper Meditech Co., Ltd
  • Eledtrocardiograph-JPD-1101B
    Features:
    1. Light in weight, compact in size
    2. Three kinds of operation mode: Automatic, Manual, Analysis
    3. Standard lead mode or European lead mode available
    4. Detection and alarm of lead-off, No paper or no battery
    Built-in ECG simulator
    6. Automatic adjustment of baseline for optional recording
    7. RS 232 communication interface for linking to special network or setting up of ECG database
    8. Optional blue tooth interface
    9. Automatic measurement, optional interpretation function in Class G machine
    10. Display of ECG waveform on LCD (Available in Class C and G machine)
    11. Bulit-in help function: Electrode positioning, ECG basic knowledge, dispose of common breakdown etc. (Available in Class G machine)
    12. Clinical information such as patient ID, name, sex, age, height, weight, drugs and hospital name can be input( Available in Class G machine)
    13. Case storage function: 15cases can be saved in the machine or as much as 150cases in a SD card. Saved ECG waveforms can be cine-looped, printed out or transferred to PC. (Available in Class G machine)

    Specification

    Safety standard: IEC class I, type CF
    Acquisition Mode: 12lead acquisition simultaneously
    Input Circuit: Floating, protection against defibrillator and pacemaker
    A/D converter: 18bit
    Frequency response: 0.05-150HZ
    Sensitivity: 2.5, 5, 10, 20mm/mv, auto
    Input impedance:≥50MΩ


    Company: Shenzhen Jumper Meditech Co., Ltd
  • Eledtrocardiograph-JPD-1101C
    Features:
    1. Light in weight, compact in size
    2. Three kinds of operation mode: Automatic, Manual, Analysis
    3. Standard lead mode or European lead mode available
    4. Detection and alarm of lead-off, No paper or no battery
    Built-in ECG simulator
    6. Automatic adjustment of baseline for optional recording
    7. RS 232 communication interface for linking to special network or setting up of ECG database
    8. Optional blue tooth interface
    9. Automatic measurement, optional interpretation function in Class G machine
    10. Display of ECG waveform on LCD (Available in Class C and G machine)
    11. Bulit-in help function: Electrode positioning, ECG basic knowledge, dispose of common breakdown etc. (Available in Class G machine)
    12. Clinical information such as patient ID, name, sex, age, height, weight, drugs and hospital name can be input( Available in Class G machine)
    13. Case storage function: 15cases can be saved in the machine or as much as 150cases in a SD card. Saved ECG waveforms can be cine-looped, printed out or transferred to PC. (Available in Class G machine)

    Specification

    Safety standard: IEC class I, type CF
    Acquisition Mode: 12lead acquisition simultaneously
    Input Circuit: Floating, protection against defibrillator and pacemaker
    A/D converter: 18bit
    Frequency response: 0.05-150HZ
    Sensitivity: 2.5, 5, 10, 20mm/mv, auto
    Input impedance:≥50MΩ


    Company: Shenzhen Jumper Meditech Co., Ltd
  • digital single channel ECG

    Features:
    High-resolution thermal printing array system

    Frequency response is as high as 150Hz
    Capable of printing continuously on channel trace and annotations including lead mark

    and parameter such as sensitivity, paper speed and filter operation status
    High resolution digital filter inhibits baseline drift without affecting ECG waveform

    One-touch operation

    Concept of floating input circuit meets IEC safety standard

    Rechargeable battery supporting more than 50 patient examinations

    Lead Standard: 12 leads
     


    Company: Contec medical
  • ECG workstation CONTEC8000A

    Feature

    1.Connected with laptop computer to form a portable ECG workstation
    2.Patient is completely isolated from computer sets,?which absolutely ensure the safety of patients.
    3.Digital signal, no interference with other devices
    4.High sampling rate, 1000sampling/sec
    5.Digital filter system
    6.The technique of anti-baseline-drift ensures the? stability of ECG signal baseline
    7.Wilson and Frank modes
    8.The power module meets the international standard? of IEC601-1
    9.Easy to operate and perfect printout
    10.Diagnosis of coronary heart disease with 12-lead
    11.Perfect time domain, frequency domain, and???nonlinear HRVanalysis
    12.Perfect ECG database management system
    ?
    Technical parameters
    ECG box (patient isolation and data acquisition)
    12 Lead ECG cable
    Sample rate :1000Hz
    RS232 interface with PC
    Sample rate :500Hz
    Resolution :12bit
    Receiver power :5.0V (DC)
    Lead:12 lead standard ECG
    Nine functions
    12-lead ECG with auto interpretation ,High frequency ECG,FCG,VLP,VCG,QT
    dispersion ,TVCG,HRV
     


    Company: Contec medical
  • digital twelve channel ECG

    ECG-1200B Digital Twelve Channel ECG
    Input Circuit : Floating; Protection against Defibrillator effect
    Lead: Standard 12 leads ,Lead change automatically
    Patient Current Leakage:<10 μ A
    Input Impedance:≥50 ΜΩ
    Calibrating Voltage: 1mV ±3%
    A/D Conversion:12 bit
    Display:320×240LCD
    Frequency Response:0.05Hz-150Hz
    Time Constant:>3.2seconds
    CMRR:>80d>100dB(with filter)
    Paper Speed:25,50mm/s±3%
    Recording Paper: 210mm×30m, Roll paper
    Input Circuit Current: ≤50nA
    Safety Standard: IEC class I, type CF
    Sensitivity: 1/2,1,2(cm/mV)
    Skin Voltage Tolerance: ±300mV
    Noise Level:<15 μVp-p
    Weight: 5.1kg
    Feature:

    Simultaneous 12 leads acquisition and printing
    Automatic measurement and interpretation;R-R analysis
    12 leads simultaneous display on large backlight LCD 320×240
    Digital design and filter ;Thermal array printer
    Baseline auto-adjustable;Rhythm lead selectable
    DC/AC autoexchange,built-in rechargeable battery.Power supports continuously working
    for more than 50 patients


    Company: Contec medical
  • ECG Machine 12-Channel with Interpretation Model
    Features
    Light, compact, 5.7 inch screen with A4 size thermal recorder
    Simultaneous acquisition of 12-lead ECG data
    Real-time recording and printing of 12-channel ECG waveform
    Graphic display of 12-lead ECG waveform
    Built-in analysis software of age which assures accurate analysis result
    Auto-measurement, auto-interpretation, waveform playback and storage of ECG data
    RS232 and USB interface cope with data-share or remote data management requirement
    Option wireless function makes more convenient communication with PC
    User friendly operation system contributed by built-in HELP function
    Literal and graphic operation interface
    Powerful filters to minimize interference
    Heart rate measurement and pace-maker protection circuit
    Multiprinting formats: manual/automatic, standard 12 channel, 3 channel plus
    3 rhythm lead, 6 channel, 6 channel plus rhythm lead, 60s analysis of
    arrhythmia, R-R histogram, trend graph
    AC, DC or built-in lithium battery power supply, alarm of battery weak and lead-off
    Comfort and durability contributed by silicon gel keypad
    Tremendous ECG data can be saved in built-in SD card

    Company: Hygeia Medical Devices (Shenzhen) Co., Ltd
  • Business partership
    Dear Sir:
    I am very glad to know you!
    We are one of leading manufacturer with high prestige in China medical industry.
    Now our main product are: Digital Electrocardiograph, All-Digital Ultrasound Diagnostic System.
    If you are interested in these product, Please feel free to contact with me on email address:
    Tessa.zoncare@hotmail.com. Then I will send the detail information and quotation to you .
    I hope we can have a chance to set up the business cooperation in the future.
     
    Thanks a lot and wait for your soon.
     

    Company: Wuhan zoncare Electroncs Co ltd
Select to
Page 3 of 13    3 ......
Go to Page