  • Smart Infusion Pump

    Specification:
    Pump Type Rate (ml/h) Remark
    XD 1~1100 Normal IV SET

    Accuracy: Dedicated IV SET:  3%
    Standard IV SET:  5%
    Preset total infusion volume: 1~9999ml
    Occlusion sensitivity: Adjustable(low, middle, high)
    KVO rate: 1~5ml/h
    Power supply: 220+20VAC, 50+1Hz
    Power consumption: 18VA
    Battery LifeL When battery fully charged, pump can continuously work about 3 hours at an flow rate of 100ml/h.
    Work Condition
    Circumstance Temperature: 10 ~40C, infusion precision will decrease when temperature  18C
    Relative Humidity: 30~75%
    Atmospheric Pressure: 700~1060HPa
    Pump dimension (mm): 176 * 128 * 225
    Pump weight: About 3kg
     


    Company: Beijing Kellymed Co.,Ltd
  • Smart Infusion Pump

    Specification:
    Pump Type Rate (ml/h) Remark
    XD 1~1100 Normal IV SET

    Accuracy: Dedicated IV SET:  3%
    Standard IV SET:  5%
    Preset total infusion volume: 1~9999ml
    Occlusion sensitivity: Adjustable(low, middle, high)
    KVO rate: 1~5ml/h
    Power supply: 220+20VAC, 50+1Hz
    Power consumption: 18VA
    Battery LifeL When battery fully charged, pump can continuously work about 3 hours at an flow rate of 100ml/h.
    Work Condition
    Circumstance Temperature: 10 ~40C, infusion precision will decrease when temperature  18C
    Relative Humidity: 30~75%
    Atmospheric Pressure: 700~1060HPa
    Pump dimension (mm): 176 * 128 * 225
    Pump weight: About 3kg
     


    Company: Beijing Kellymed Co.,Ltd
  • Smart Feeding Pump ZNB-XY1

    ZNB-XY1 nourishment infusion pump, a high-tech product with unique design and futher development.It features greater convenience and versatility. It is able to deliver gastrointestinal nourishment and common intravenous fluids in hospital ward and family. It is also used in scientific research and liquids infusion requires high accuracy.

    Technical specification:
     
    1. Flow rate range
    10 to 2000ml/h,
    2. Infusion accuracy
     10% if use recommended silica gel tube
     30% if deliver in mass units
    3. Required volume
    1 to 9999 ml,
    4. Power supply
    220+20 VAC, 50+1 Hz
    5. Power consumption
    18VA
    6. Operating temperature range
    Ambient temperature: 10 to 40  C
    Relative humidity: 30% to 75%
    7. Outline dimension
    D  W  H: 100 mm 115 mm 140 mm
    8. Weight:2 kg
    9. Safety classification
    Class I, BF, general device.
     


    Company: Beijing Kellymed Co.,Ltd
  • Smart Feeding Pump ZNB-XY1

    ZNB-XY1 nourishment infusion pump, a high-tech product with unique design and futher development.It features greater convenience and versatility. It is able to deliver gastrointestinal nourishment and common intravenous fluids in hospital ward and family. It is also used in scientific research and liquids infusion requires high accuracy.

    Technical specification:
     
    1. Flow rate range
    10 to 2000ml/h,
    2. Infusion accuracy
     10% if use recommended silica gel tube
     30% if deliver in mass units
    3. Required volume
    1 to 9999 ml,
    4. Power supply
    220+20 VAC, 50+1 Hz
    5. Power consumption
    18VA
    6. Operating temperature range
    Ambient temperature: 10 to 40  C
    Relative humidity: 30% to 75%
    7. Outline dimension
    D  W  H: 100 mm 115 mm 140 mm
    8. Weight:2 kg
    9. Safety classification
    Class I, BF, general device.
     


    Company: Beijing Kellymed Co.,Ltd
  • Smart Infusion Pump ZNB-XA
    Specification:
    1)Presetting infusing volume range 1ml~9999mL, 1mL step
    2)Flow rate range: 1ml/h ~1100mL/h, 1mL step
    3)Bolus\Purge: Purge when pump stops, bolus when pump works, average speed: 700mL/h
    4)KVO speed 4mL/h
    5)Speed mode "drop/min""ml/h"
    6)Infusion Accuracy ± 5%(adjustable)
    7)Alarm Functions: Infusion occlusion, air bubble, infusion completion, low battery, drop error, door open, no operation and unusual speed
    8)Other functions: Accumulated volume display, AC/DC automatic switching, mute, nurse call, car power supply, wireless(optional)
    9)Matching Features: Wireless mode(with monitor software)\drop sensor
    10)LED Screen Displayed information Presetting/accumulated volume\flow rate\alarm and working condition
    11)Power supply AC: 220V± 22V 50Hz± 1Hz
       Internal power supply(inside battery): 9.6V± 1.6V
       External power supply(ambulance power supply): 12V± 2V
       Power Consumption: No more than 20VA
       Inside battery operation time With fully charged battery, working time is over 3 hours at the flow rate of 30mL/h
    12)Safety Classification Class I with power supply inside, BF type common equipment, continuous working
    Container protection grade: IPX3
    Container material PC+ABS, fire resistance grade: V-0(UL94 standard)
    13)Weight About 2.5Kg
    14)Dimensions 130mm× 145mm× 228mm(excluding prominent part)
    15)Working Condition Environment temperature: 10~30 C
    16)Relative humidity: 30%~75%
    17)Atmospheric pressure: 860hPa ~1060hPa
    18)Storage Condition Storage temperature: -20 ~+55 degree Centigrade
    19)Relative humidity: No more than93% no condensation
    20)Atmospheric pressure: 500hPa~1060hPa
    Applicable Standard GB9706.1-2007\GB9706.27-2005\IEC60601-1\IEC60601-2-24


    Company: Beijing Kellymed Co.,Ltd
  • Smart Infusion Pump ZNB-XA
    Specification:
    1)Presetting infusing volume range 1ml~9999mL, 1mL step
    2)Flow rate range: 1ml/h ~1100mL/h, 1mL step
    3)Bolus\Purge: Purge when pump stops, bolus when pump works, average speed: 700mL/h
    4)KVO speed 4mL/h
    5)Speed mode "drop/min""ml/h"
    6)Infusion Accuracy ± 5%(adjustable)
    7)Alarm Functions: Infusion occlusion, air bubble, infusion completion, low battery, drop error, door open, no operation and unusual speed
    8)Other functions: Accumulated volume display, AC/DC automatic switching, mute, nurse call, car power supply, wireless(optional)
    9)Matching Features: Wireless mode(with monitor software)\drop sensor
    10)LED Screen Displayed information Presetting/accumulated volume\flow rate\alarm and working condition
    11)Power supply AC: 220V± 22V 50Hz± 1Hz
       Internal power supply(inside battery): 9.6V± 1.6V
       External power supply(ambulance power supply): 12V± 2V
       Power Consumption: No more than 20VA
       Inside battery operation time With fully charged battery, working time is over 3 hours at the flow rate of 30mL/h
    12)Safety Classification Class I with power supply inside, BF type common equipment, continuous working
    Container protection grade: IPX3
    Container material PC+ABS, fire resistance grade: V-0(UL94 standard)
    13)Weight About 2.5Kg
    14)Dimensions 130mm× 145mm× 228mm(excluding prominent part)
    15)Working Condition Environment temperature: 10~30 C
    16)Relative humidity: 30%~75%
    17)Atmospheric pressure: 860hPa ~1060hPa
    18)Storage Condition Storage temperature: -20 ~+55 degree Centigrade
    19)Relative humidity: No more than93% no condensation
    20)Atmospheric pressure: 500hPa~1060hPa
    Applicable Standard GB9706.1-2007\GB9706.27-2005\IEC60601-1\IEC60601-2-24


    Company: Beijing Kellymed Co.,Ltd
  • Syringe Pump
    1.HD LCD Display,high capacity words,friendly user interface,dynamically display working status.
    2.Compatible with 10ml,20ml,30ml,50ml(60ml) syringes of all brands
    3.Human voice alarm function: voice prompt and alarm will sound when injection is almost done,injection is finished,preset dosage is done,an injection blockage occurs,syringe device is improperly installed,a wrong speed is set,AC is unplugged,battery is close to zero.This further greatly reduces the workload of nurses(only available from our company)
    4.One-key operation makes setup easy and simple
    5.Three Vein Infusion Models:
    A.Time-Volume Mode:by setting the time and injection volume,the system does the injection after automatic speed calculation.
    B.Dosage Weight Mode:by setting the volume,weight,medicament,dosage,the system does the injection after automatic speed calculation.
    C.Esay Speed-Setting Mode:the normal one hospitals used.
    6.Function to remove bubbles in the tube fast.
    7.Function to handle fast speed and large volume(bolus)
    8.The system automatically opens up KVO after injection(reopens vein circulation)
    9.Function to Preset Solution Volume:the user can preset solution volume.The machine will automatically stop and start KVO function once the preset solution volume is finished.
    10.The machine automatically records the settings for last injection.It greatly reduces the workload for users.
    11.Function to Auto-Define a Syringe:complete calibration technology for syringe brand definition that ensures the compatibility of any syringe brand and injection accuracy.
    12.Freely Stackable:You freely stack one onto another to provide multiple solutions,combination solutions that have a wide range of clinical applications.
    13.Three Power Source:AC220,50Hz,Internal Battery,12V car charge
    14.Connecting Port for Nurse-Paging
    15.Syringe Plunger Grabble Detector.Operable with one hand in a No-Germ Environment


    Company: Changsha BEYOND Medical Devices Co.,Ltd
  • Syringe Pump
    1.HD LCD Display,high capacity words,friendly user interface,dynamically display working status.
    2.Compatible with 10ml,20ml,30ml,50ml(60ml) syringes of all brands
    3.Human voice alarm function: voice prompt and alarm will sound when injection is almost done,injection is finished,preset dosage is done,an injection blockage occurs,syringe device is improperly installed,a wrong speed is set,AC is unplugged,battery is close to zero.This further greatly reduces the workload of nurses(only available from our company)
    4.One-key operation makes setup easy and simple
    5.Three Vein Infusion Models:
    A.Time-Volume Mode:by setting the time and injection volume,the system does the injection after automatic speed calculation.
    B.Dosage Weight Mode:by setting the volume,weight,medicament,dosage,the system does the injection after automatic speed calculation.
    C.Esay Speed-Setting Mode:the normal one hospitals used.
    6.Function to remove bubbles in the tube fast.
    7.Function to handle fast speed and large volume(bolus)
    8.The system automatically opens up KVO after injection(reopens vein circulation)
    9.Function to Preset Solution Volume:the user can preset solution volume.The machine will automatically stop and start KVO function once the preset solution volume is finished.
    10.The machine automatically records the settings for last injection.It greatly reduces the workload for users.
    11.Function to Auto-Define a Syringe:complete calibration technology for syringe brand definition that ensures the compatibility of any syringe brand and injection accuracy.
    12.Freely Stackable:You freely stack one onto another to provide multiple solutions,combination solutions that have a wide range of clinical applications.
    13.Three Power Source:AC220,50Hz,Internal Battery,12V car charge
    14.Connecting Port for Nurse-Paging
    15.Syringe Plunger Grabble Detector.Operable with one hand in a No-Germ Environment


    Company: Changsha BEYOND Medical Devices Co.,Ltd
  • Double Channel Syringe Pump
    1.HD LCD Display,high capacity words,friendly user interface,dynamically display working status.
    2.Compatible with 10ml,20ml,30ml,50ml(60ml) syringes of all brands
    3.Alarm function:Machine will give alarm when injection is almost done,injection is finished,preset dosage is done,an injection blockage occurs,syringe device is improperly installed,a wrong speed is set,AC is unplugged,battery is close to zero.This further greatly reduces the workload of nurses(only available from our company)
    4.One-key operation makes setup easy and simple
    5.Three Vein Infusion Models:
    A.Time-Volume Mode:by setting the time and injection volume,the system does the injection after automatic speed calculation.
    B.Dosage Weight Mode:by setting the volume,weight,medicament,dosage,the system does the injection after automatic speed calculation.
    C.Esay Speed-Setting Mode:the normal one hospitals used.
    6.Function to remove bubbles in the tube fast.
    7.Function to handle fast speed and large volume(bolus)
    8.The system automatically opens up KVO after injection(reopens vein circulation)
    9.Function to Preset Solution Volume:the user can preset solution volume.The machine will automatically stop and start KVO function once the preset solution volume is finished.
    10.The machine automatically records the settings for last injection.It greatly reduces the workload for users.
    11.Function to Auto-Define a Syringe:complete calibration technology for syringe brand definition that ensures the compatibility of any syringe brand and injection accuracy.
    12. Three Power Source:AC220,50Hz,Internal Battery,12V car charge
    13. Connecting Port for Nurse-Paging
    14. Syringe Plunger Grabble Detector.Operable with one hand in a No-Germ Environment.

    Company: Changsha BEYOND Medical Devices Co.,Ltd
  • Double Channel Syringe Pump
    1.HD LCD Display,high capacity words,friendly user interface,dynamically display working status.
    2.Compatible with 10ml,20ml,30ml,50ml(60ml) syringes of all brands
    3.Alarm function:Machine will give alarm when injection is almost done,injection is finished,preset dosage is done,an injection blockage occurs,syringe device is improperly installed,a wrong speed is set,AC is unplugged,battery is close to zero.This further greatly reduces the workload of nurses(only available from our company)
    4.One-key operation makes setup easy and simple
    5.Three Vein Infusion Models:
    A.Time-Volume Mode:by setting the time and injection volume,the system does the injection after automatic speed calculation.
    B.Dosage Weight Mode:by setting the volume,weight,medicament,dosage,the system does the injection after automatic speed calculation.
    C.Esay Speed-Setting Mode:the normal one hospitals used.
    6.Function to remove bubbles in the tube fast.
    7.Function to handle fast speed and large volume(bolus)
    8.The system automatically opens up KVO after injection(reopens vein circulation)
    9.Function to Preset Solution Volume:the user can preset solution volume.The machine will automatically stop and start KVO function once the preset solution volume is finished.
    10.The machine automatically records the settings for last injection.It greatly reduces the workload for users.
    11.Function to Auto-Define a Syringe:complete calibration technology for syringe brand definition that ensures the compatibility of any syringe brand and injection accuracy.
    12. Three Power Source:AC220,50Hz,Internal Battery,12V car charge
    13. Connecting Port for Nurse-Paging
    14. Syringe Plunger Grabble Detector.Operable with one hand in a No-Germ Environment.

    Company: Changsha BEYOND Medical Devices Co.,Ltd
Select to
Page 2 of 4    2
Go to Page