Other Monitoring & Diagnostic Equipments trade,Other Monitoring & Diagnostic Equipments offer, Sell leads
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
Select to
Page 2 of 6
  • PM-06C ECG&SPO2 monitor

    Features:
    ■ Routine Check Mode and Continuous Monitoring Mode
    ■ Data Graph and Trend Table Review
    ■ Rich Analysis Report
    ■ Perfect Mount Solution
    ■ Convenient operation by touch screen
    ■ Large SD card memory for more than 2000 patient cases storage
    ■ Sync with PC based Sofrware (WinXP and WinVista)
    Technical specifications:
    ■ Safety
    ■ Meet the requirment of IEC60601 series
    ■ Type of Protection:Class II with internal electirc power ¡ösupply
    ■ Degree of Protection:BF
    ■ Dimention and Weight
    ■ Dimention:92(W)x82(H)x22(D)mm
    ■ Weight:136g(with battery)
    Operation Environment:
    ■ Temperature:0℃~ +40℃
    ■ Humidity:15% ~ 95%
    Storage Environment:
    ■ Temperature: -20℃~ +60℃
    ■ Humidity:10% ~ 95%
    ■ Patient Range
    ■ Neonate ,Pediatric and Adult
    SPO2:
    ■ Measurement Range:0 ~ 100%
    ■ Resolution:1%
    ■ Accuracy: ±2%(70%~100%, Adult/Pediatric, non-motion)
    ±3%(70%~100%, Neonate, non-motion)
    0% ~ 69% unspecified
    ■ Alarm Range:0% ~ 100%
    ■ Refreshing Rate:1s
    Pulse Rate:
    ■ Measurement Range:25 ~ 250 bpm
    ■ Resolution:1bpm
    ■ Accuracy:±3 bpm (non-motion)
    ■ Alarm Range:25 ~ 250 bmp
    ■ Refreshing Rate:1s
    ECG:
    ■ Lead mode:3-lead or 5-lead
    ■ Lead selection: I, II, III, AVR, AVL, AVF, V
    ■ HR range:15 ~ 300 bpm
    ■ ECG Waveform:2 channals
    ■ Accuracy:±2bpm or ±2%, which is greater
    ■ S-T segment detection, range: -2.0mv ~ +2.0mv
    ■ Arrhythmia analysis: 13 kinds of arrhythmia
    ■ Alarm Range:15 ~ 300 bpm


    Company: Contec medical
  • Infrared Mammary Diagnostic Apparatus

    • All digital image processing technology

    • All Chinese (Window) interface operation

    • Function of color image processing

    • All kinds of measurement function, diameter, perimeter, area

    • Image enhancement, margin processing energy dividing and partial magnification, negative film display

    • Printing of nice color report

    • Storage of above 100,000images

    • Imported pick up camera and imported color indicator , import color ink printer.

     


    Company: Xuzhou Shengpu Medical Instrument Technical & Equipment Co., LTD
  • Fetal & Material Monitor (JPD600P)

    JPD-600P 12.1 LCD

    Features:

    1. 12.1 high-resolution color TFT LCD display, support plug-in large-screen CRT display

    2.Standard Configure: FHR,TOCO,Fetal Movement, ECG, Spo2, NIBP, RESP, TEMP, Pulse Rate

    3. Optional twins

    4. Portable, convenient monitor

    5. Built-in rechargeable battery, AC-DC power supply, without interruption Monitor

    6.Dynamic save and display the Monitoring information within 48 hours

    7.Both Use lonely or Connect with a Central Monitor network

    8. Support the extension almost for 128 units central monitor system.

    9. Quality “Sanyo” speaker take more clear and lound sound.

    10. usual thermal paper,more economical.

     

    Specification:

    FHR:

    Ultrasound Probe: 12pcs chip, Multi-wafer,wave-beam,high sensitive

    Ultrasound frequency: 1MHz±5%

    Ultrasound intensity: <3mW/cm2

    FHR range: 30-240bpm

    Resolution:1bpm

    Accuracy:± 1bpm/±1%

    TOCO:

    TOCO range: 0-100 (relative unit)

    Resolution:1

    Non-linear error:≤±5%

    Fetal Movement:

    Button Hand Count( Automatic cumulative number of movements)

    NIBP:

    Measurement Units:mmHg/Kpa optional

    Pressure protection: A double security protection software and hardware

    Work Mode: Auto,Manual

    Measurement intervals: 2-60 minutes set up

    Survey: : Systolic blood pressure:60-240 mmHg
                Average Blood Pressure:40-200 mmHg
                Diastolic Blood Pressure: 30-180 mmHg

    Resolution:1mmHg

    Accuracy:±3mmHg

    Pulse rate:40-240bpm

    SPO2:

    Range:70%-99%

    Resolution:1%

    Accuracy:±2 Effective digital

    Pulse Rate:

    Range:40-240bpm

    ECG:

    Range: 30-300bpm

    Accuracy:±1bpm/±1%

    Choice:III IIIaVRaVLaVFV

    Scan Speed:12.5mm/s25mm/s50mm/s

    Gain choice:x0.25x0.5x1x2

    Application:Diagnosis,Monitor,Surgery

    RESP:

    Range:1-99rpm

    Resolution:1rpm

    Accuracy:±2rpm

    TEMP:

    Range:26- 45

    Resolution:0.1

    Accuracy:±0.2%

    Work environment:

    Operation Temperature: 5- 40

    Relative temperature:≤80%

    Atmospheric pressure: (86-106)Kpa,32- 45:±0.1

     

    Printer

    50mm usual thermal paper,more economical


    Company: Shenzhen Jumper Medical Equipment Co., Ltd.
  • Fetal & Material Monitor (JPD600P)

    JPD-600P 12.1 LCD

    Features:

    1. 12.1 high-resolution color TFT LCD display, support plug-in large-screen CRT display

    2.Standard Configure: FHR,TOCO,Fetal Movement, ECG, Spo2, NIBP, RESP, TEMP, Pulse Rate

    3. Optional twins

    4. Portable, convenient monitor

    5. Built-in rechargeable battery, AC-DC power supply, without interruption Monitor

    6.Dynamic save and display the Monitoring information within 48 hours

    7.Both Use lonely or Connect with a Central Monitor network

    8. Support the extension almost for 128 units central monitor system.

    9. Quality “Sanyo” speaker take more clear and lound sound.

    10. usual thermal paper,more economical.

     

    Specification:

    FHR:

    Ultrasound Probe: 12pcs chip, Multi-wafer,wave-beam,high sensitive

    Ultrasound frequency: 1MHz±5%

    Ultrasound intensity: <3mW/cm2

    FHR range: 30-240bpm

    Resolution:1bpm

    Accuracy:± 1bpm/±1%

    TOCO:

    TOCO range: 0-100 (relative unit)

    Resolution:1

    Non-linear error:≤±5%

    Fetal Movement:

    Button Hand Count( Automatic cumulative number of movements)

    NIBP:

    Measurement Units:mmHg/Kpa optional

    Pressure protection: A double security protection software and hardware

    Work Mode: Auto,Manual

    Measurement intervals: 2-60 minutes set up

    Survey: : Systolic blood pressure:60-240 mmHg
                Average Blood Pressure:40-200 mmHg
                Diastolic Blood Pressure: 30-180 mmHg

    Resolution:1mmHg

    Accuracy:±3mmHg

    Pulse rate:40-240bpm

    SPO2:

    Range:70%-99%

    Resolution:1%

    Accuracy:±2 Effective digital

    Pulse Rate:

    Range:40-240bpm

    ECG:

    Range: 30-300bpm

    Accuracy:±1bpm/±1%

    Choice:III IIIaVRaVLaVFV

    Scan Speed:12.5mm/s25mm/s50mm/s

    Gain choice:x0.25x0.5x1x2

    Application:Diagnosis,Monitor,Surgery

    RESP:

    Range:1-99rpm

    Resolution:1rpm

    Accuracy:±2rpm

    TEMP:

    Range:26- 45

    Resolution:0.1

    Accuracy:±0.2%

    Work environment:

    Operation Temperature: 5- 40

    Relative temperature:≤80%

    Atmospheric pressure: (86-106)Kpa,32- 45:±0.1

     

    Printer

    50mm usual thermal paper,more economical


    Company: Shenzhen Jumper Medical Equipment Co., Ltd.
  • Rapid Test Kits-Chinese

    We are professional manufacture and exporter of rapid test kits. Our products are including fertility tests, infectious disease test, drug of abuse test, cardiac marker test, tumor marker test, urinalysis, etc.


    Company: Nanjing Kim-Lehman Medical Instrument Co., Ltd.
  • Rapid Test Kits-Chinese

    We are professional manufacture and exporter of rapid test kits. Our products are including fertility tests, infectious disease test, drug of abuse test, cardiac marker test, tumor marker test, urinalysis, etc.


    Company: Nanjing Kim-Lehman Medical Instrument Co., Ltd.
  • Fetal Doppler BF-530
    Pocket Fetal Doppler mainly applies to detect the fetal heartbeat rate from the twelfth week;

    LCD can display FHR data and heart rate graphics, battery indicator, volume of sound and alarm indicator;

    Built-in rechargeable battery can work continuously more than 4 hours;

    White backlight LCD display for use conveniently at night;

    Automatic power off (one minute), self-detect function and alarm function when FHR is out of the normal range or battery power is in shortage;

    Only 270g, can be carried with conveniently with an earphone, gllus and portable handbag;

    Built-in speaker, collocate with earphone jack;

    1.0MHz probe,optional 5.0MHz probe for blood stream.

    Company: ShenZhen Bestman Instrument Co.,Ltd
  • Fetal Doppler BF-530
    Pocket Fetal Doppler mainly applies to detect the fetal heartbeat rate from the twelfth week;

    LCD can display FHR data and heart rate graphics, battery indicator, volume of sound and alarm indicator;

    Built-in rechargeable battery can work continuously more than 4 hours;

    White backlight LCD display for use conveniently at night;

    Automatic power off (one minute), self-detect function and alarm function when FHR is out of the normal range or battery power is in shortage;

    Only 270g, can be carried with conveniently with an earphone, gllus and portable handbag;

    Built-in speaker, collocate with earphone jack;

    1.0MHz probe,optional 5.0MHz probe for blood stream.

    Company: ShenZhen Bestman Instrument Co.,Ltd
Select to
Page 2 of 6    2
Go to Page