Other Medical System trade,Other Medical System offer, Sell leads
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
Select to
Page 2 of 9
  • PTCA Balloon Dilatation Catheter
    Description:

    1. Semi-compliant RX PTCA balloon dilation catheter helps to achieve successful treatment to patients.
    2. Flexible tip design provides excellent crossability to navigate through tight lesions and tortuous anatomy.
    3. Hypotube shaft construction is designed to deliver powerful push to the lesions.
     
    Technical Specifications:
    Catheter Design                            Rapid Exchange
    Balloon Compliance                    Semi-compliant
    Marker                                    2
    Material                            Nylon 12
    Nominal Pressure                    2.0-3.0mm 8atm
                                               3.5- 4.0mm 6 atm
    Rated Burst Pressure                    2.0-3.5mm 16 atm
                                               4.0mm 14 atm
    Distal Shaft "outer diameter"            2.8 Fr
    Proximal Shaft "outer diameter"            2.3 Fr
    Crossing Profile                    0.026~0.030"
    Usable Catheter Length                    135 cm
    Minimum Guiding Catheter Compatibility    5Fr / 0.056"
    Guide wire Compatible                    0.014"

    Company: Yilson Development Co.,Ltd
  • Radial Artery Compression Tourniquet

    Description:
    Designed to safely and comfortably stop bleeding.
    Specially designed for radial artery hemostasis post percutaneous puncture. Transparency material ensures clear visual control of homeostasis procedure Unilateral valve connected to balloon permits accurate pressure adjustment, providing personalized hemostasis strategy. Adjustable band length provides precise fit for patient comfort.

    Balloon Volume (ml):    20


    Company: Yilson Development Co.,Ltd
  • RUNNER Coronary Stent System

    Descriptions:
    A "classical" coronary stent with stainless steel platform and open cell design suitable for most stenty procedure. The device offers excellent flexibility, crossability and radial strength. The product has a complete diameter range from 2.5mm to 4.0mm and the length of 9 ~ 33mm.

    Stent Specifications:
    Stent Material:  316L Stainless Steel
    Stent Strut Thickness: 0.100+~0.010 mm
    Metal Coverage Area: 14.6% ( 3.0mm stent )
    Stent Length Shortening:< 3% ( 3.0mm sent )
    Radial Force:    High
    Stent Crossing Profile: < 1.0 mm

    Balloon Specifications:
    Prox Shaft Material: PTFE Coated Hypotube
    Prox Shaft Diameter: 2.0 F
    Dist. Shaft Diameter: 2.5~2.75 mm, 2.55 F
                            3.0 ~ 4.0 mm, 2.7 F
    Transition Prox/Dist. Shaft: Tri~extrusion / SS Tube
    Balloon Material: Nylon
    Compliance:      Semi
    Nominal Pressure: 6 atm
    Rated Burst Pressure: 16 atm
    Average Burst Pressure: 20 atm
    Profile:         0.030" ( 3.0mm stent )
    Lesion Entry Profile: 0.016"
    Tip Design:      Tapered Soft
    Working Length:  142 cm
    Balloon Pleads:  3


    Company: Yilson Development Co.,Ltd
  • RAPA Sirolimus Eluting Coronary Stent System

    Descriptions:

    This DES uses a biodegradable polymer coating on the stainless steel stent platform. The proprietary, top-quality coating process allows the integrity of coated polymer after excessive stent expansion and a systemic elution of sirolimus in a well -controlled fashion after the stent implantation. The safety and efficacy of the product is well documented from a related randomized trial in Europe in CTO patients showing low re-stenosis rate and very promising late loss data.

    Stent Specifications:
    Stent Platform:   316L Stainless Steel
    Coating Material: PLGA ( Biodegradable )
    Coating Thickness: 4.0 +~ 1.0mm
    Drug:                Sirolimus ( Rapamycine )
    Drug Content:    170pg/cm2 +~ 20pg/cm2 (12mm, 18mm )
                            150pg/cm2 +~ 20pg/cm2 ( 23mm, 28mm, 33mm)
    Degradation Time: < 2 months


    Company: Yilson Development Co.,Ltd
  • PTCA Balloon Dilatation Catheter
    Description:

    1. Semi-compliant RX PTCA balloon dilation catheter helps to achieve successful treatment to patients.
    2. Flexible tip design provides excellent crossability to navigate through tight lesions and tortuous anatomy.
    3. Hypotube shaft construction is designed to deliver powerful push to the lesions.
     
    Technical Specifications:
    Catheter Design                            Rapid Exchange
    Balloon Compliance                    Semi-compliant
    Marker                                    2
    Material                            Nylon 12
    Nominal Pressure                    2.0-3.0mm 8atm
                                               3.5- 4.0mm 6 atm
    Rated Burst Pressure                    2.0-3.5mm 16 atm
                                               4.0mm 14 atm
    Distal Shaft "outer diameter"            2.8 Fr
    Proximal Shaft "outer diameter"            2.3 Fr
    Crossing Profile                    0.026~0.030"
    Usable Catheter Length                    135 cm
    Minimum Guiding Catheter Compatibility    5Fr / 0.056"
    Guide wire Compatible                    0.014"

    Company: Yilson Development Co.,Ltd
  • Radial Artery Compression Tourniquet

    Description:
    Designed to safely and comfortably stop bleeding.
    Specially designed for radial artery hemostasis post percutaneous puncture. Transparency material ensures clear visual control of homeostasis procedure Unilateral valve connected to balloon permits accurate pressure adjustment, providing personalized hemostasis strategy. Adjustable band length provides precise fit for patient comfort.

    Balloon Volume (ml):    20


    Company: Yilson Development Co.,Ltd
  • RUNNER Coronary Stent System

    Descriptions:
    A "classical" coronary stent with stainless steel platform and open cell design suitable for most stenty procedure. The device offers excellent flexibility, crossability and radial strength. The product has a complete diameter range from 2.5mm to 4.0mm and the length of 9 ~ 33mm.

    Stent Specifications:
    Stent Material:  316L Stainless Steel
    Stent Strut Thickness: 0.100+~0.010 mm
    Metal Coverage Area: 14.6% ( 3.0mm stent )
    Stent Length Shortening:< 3% ( 3.0mm sent )
    Radial Force:    High
    Stent Crossing Profile: < 1.0 mm

    Balloon Specifications:
    Prox Shaft Material: PTFE Coated Hypotube
    Prox Shaft Diameter: 2.0 F
    Dist. Shaft Diameter: 2.5~2.75 mm, 2.55 F
                            3.0 ~ 4.0 mm, 2.7 F
    Transition Prox/Dist. Shaft: Tri~extrusion / SS Tube
    Balloon Material: Nylon
    Compliance:      Semi
    Nominal Pressure: 6 atm
    Rated Burst Pressure: 16 atm
    Average Burst Pressure: 20 atm
    Profile:         0.030" ( 3.0mm stent )
    Lesion Entry Profile: 0.016"
    Tip Design:      Tapered Soft
    Working Length:  142 cm
    Balloon Pleads:  3


    Company: Yilson Development Co.,Ltd
  • RAPA Sirolimus Eluting Coronary Stent System

    Descriptions:

    This DES uses a biodegradable polymer coating on the stainless steel stent platform. The proprietary, top-quality coating process allows the integrity of coated polymer after excessive stent expansion and a systemic elution of sirolimus in a well -controlled fashion after the stent implantation. The safety and efficacy of the product is well documented from a related randomized trial in Europe in CTO patients showing low re-stenosis rate and very promising late loss data.

    Stent Specifications:
    Stent Platform:   316L Stainless Steel
    Coating Material: PLGA ( Biodegradable )
    Coating Thickness: 4.0 +~ 1.0mm
    Drug:                Sirolimus ( Rapamycine )
    Drug Content:    170pg/cm2 +~ 20pg/cm2 (12mm, 18mm )
                            150pg/cm2 +~ 20pg/cm2 ( 23mm, 28mm, 33mm)
    Degradation Time: < 2 months


    Company: Yilson Development Co.,Ltd
  • CO2 laser tubes
    We provide all kinds of high quality CO2 laser tubes with different length from 250mm to 2000mm. They can be use for your medical systems.

    Company: Shanghai Jhlaser development Corperation
  • CO2 laser tubes
    We provide all kinds of high quality CO2 laser tubes with different length from 250mm to 2000mm. They can be use for your medical systems.

    Company: Shanghai Jhlaser development Corperation
Select to
Page 2 of 9    2 ......
Go to Page