  • ECG 903 Digital Three Channels Interpretive Electrocardiograph (ECG Machine)

    ECG 903 Digital Three Channels Interpretive Electrocardiograph (ECG Machine)
    Features:
    1. Simultaneous 12 leads acquisition
    2. Multiple operation mode (Manual/Auto/European Mode)
    3. Designed with a high-resolution thermal printer to print out ECG waveform, annotation as well related parameters for diagnosis reference.
    4. Digital isolation technology is adopted to minimize time/temperature drift of components so as promote adaptability of the unit to circumstance.
    5. Digital filter for effective inhabitation of baseline drift, interference, as well automatic position of baseline.
    6. Self-test upon powering on.
    7. Function of rhythem lead for observing abnormal ECG waveform and heart rate.
    8. Automatic measurement and interpretation of ECG waveform to relieve doctors from strain.
    9. AC/Rechargeable battery for supporting continuous examination when AC power supply is unavailable.

    Company: Changsha Epower Electronics & Science, CO.,LTD
  • sell vaporizer, respiratory vaporizer, anesthetic vaporizer
    Technical data:
    Concentration range:
    Halothan : 0 to 5%
    Enflurane: 0 to 5%
    Isoflurane: 0 to 5%
    Sevoflurane: 0 to 8%
    Temperature range:
    Ambient and Vapor temperature
    During operation 15 to 35oC
    During storage (empty, dry wick) -40 to 65oC
    Flow range
    0.2 to 15L/min
    0.2 to 10L/min (normal usage) For concentrations >5 vol.%
    Filling volume for anaesthetic agent:
    About 340 ml with dry wick
    About 300 ml with moist wick
    Maximum angle of tilt
    During transport (control dial at 0 ) any position and angle
    During operation straight up
    Vaporizer conforms to standards:
    ISO 5358
    ISO 8835-4
    93/42/EEC Medical Device Directive
    CE
    The keyed filling system conforms to the following Standards for
    anaesthetic-anget-specific filling systems: ISO 5360
    23mm Conical connector ISO 5356-1
    Warm up time: 5min
    Mounting type:
    Draeger plug in, Selectatec Compatible, Cagemount (ISO 23mm tapers),
    Fix Mount, Cagemount With interlock
    Filler Type:
    Pour fil, Easy-fil (Isofulrane, Halothane, Enflurane)
    Pour fil, Easy-fil, Quik fil (Sevoflurane)
    Packing material:
    a) Interior packing materials: Polyethylene bag.
    b) Interior cushioning material: EPE foam.
    c) Outer carton: corrugated cardboard boxes.
    d) Strapping material: Scotch tape.
    STANDARD:
    CE, ISO9001, ISO 8835-4, 93/42/EEC MDD, ISO 5358

    Company: Beijing Vanbonmed Co., Ltd.
  • Aeon7800A Anesthesia Machine

    Aeon7800A Anesthesia Machine

    The first Chinese anaesthesia workstation comply with USA standard           
    Suitable for neonate, pediatric & adult
    Meet low flow requirement be multi parameter monitoring
    Flowmeter backlight & bright adjustable endoscope light system
    Integrated high temperature sterilization CO2 absorber system
    Safe & reliable gas system
    CE marked, meet EU clinical requirement


    Company: China Shikang Medical Equipment Group Limited
  • Aeon7800A Anesthesia Machine

    Aeon7800A Anesthesia Machine

    The first Chinese anaesthesia workstation comply with USA standard           
    Suitable for neonate, pediatric & adult
    Meet low flow requirement be multi parameter monitoring
    Flowmeter backlight & bright adjustable endoscope light system
    Integrated high temperature sterilization CO2 absorber system
    Safe & reliable gas system
    CE marked, meet EU clinical requirement


    Company: China Shikang Medical Equipment Group Limited
  • Anesthesia system

     
    Main feature:
    ◆      Meet the Standard of GB 9706.29-Medical electrical equipment―Part 2: Particular requirements for the safety and essential performance of anaesthsia systems
    ◆      Be used for closed、semi-closed、semi-open inhalation anaesthesia, controlled or assisted ventilation, monitoring and display of the ventilation parameters.
    ◆      Applied for adult and child.
    ◆      Compacted breathing system meets the standard of ISO 8835-2. Good airtight, easy to operation, clearance and sterilization.
    ◆      Vaporizer meets the standard of ISO 8835-4. Accurate concentration, temperature、flow and pressure compensation technology. Various options of Isoflurane, Enflurane, and Sevoflurane.
    ◆      Anaesthesia ventilator meets the standard of ISO 8835-5.
              Gas driven and electrically controlled
              LCD screen
              IPPV、SIPPV、SIMV ventilation mode
              Inhalation platform and PEEP function
              Alarm, indication and protection functions for high pressure、leadoff and apnea
              Built-in battery for backup power source

    Company: SHENZHEN CHENWEI ELECTRONIC CO.,LTD
  • Anesthesia system

     
    Main feature:
    ◆      Meet the Standard of GB 9706.29-Medical electrical equipment―Part 2: Particular requirements for the safety and essential performance of anaesthsia systems
    ◆      Be used for closed、semi-closed、semi-open inhalation anaesthesia, controlled or assisted ventilation, monitoring and display of the ventilation parameters.
    ◆      Applied for adult and child.
    ◆      Compacted breathing system meets the standard of ISO 8835-2. Good airtight, easy to operation, clearance and sterilization.
    ◆      Vaporizer meets the standard of ISO 8835-4. Accurate concentration, temperature、flow and pressure compensation technology. Various options of Isoflurane, Enflurane, and Sevoflurane.
    ◆      Anaesthesia ventilator meets the standard of ISO 8835-5.
              Gas driven and electrically controlled
              LCD screen
              IPPV、SIPPV、SIMV ventilation mode
              Inhalation platform and PEEP function
              Alarm, indication and protection functions for high pressure、leadoff and apnea
              Built-in battery for backup power source

    Company: SHENZHEN CHENWEI ELECTRONIC CO.,LTD
  • AR-321 Anesthesia Machine

    Main body
        
    High-strength engineering plastic rack, light,beautiful and corrosion resistant
    Scope of application
        
    adult, child
    Gas source
        
    O2: 0.27--0.55MPa
    Flow meter
        
    O2: 0.1--2L/min    2.5--10L/min
    Flow rate of rapid oxygen supply
        
    25--75L/min
    Low oxygen pressure alarm
        
    There will be sound alarm when the oxygen
    pressure < 0.2MPa
    Vaporizer
        
    it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0--5 vol%.
    Among Halothane, Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer.
    Respiratory circuit
        
    working mode: all-close, semi-close, semi-open releasing pressure: 0.5--7 kPa
    Respiratory bellows
        
    bellows for adults, bellows for children tidal volume range:0--1500 ml
    Ventilator
    Display mode
        
    High-definition 4.8” LCD screen display
    Ventilation mode
        
    IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate)
    Ventilation parameters
        
    Tidal volume         50--1500ml
    Rate                2--99 bpm
    SIMV rate                2--20 bpm
    I:E                2:1--1:8
    Inspiratory trigger pressure -1.0--2.0 kPa
    Pressure range        1.0--6.0 kPa
     
    Parameters for ventilation monitoring
        
    tidal volume, ventilation volume, IPPV rate, I/E, peak pressure of airway, inspiratory trigger pressure, pressure - time waveform
    Security Alarm System
    Airway pressure alarm
        
    upper limit setting range 1.0--6.0 kPa
    low limit setting range    0.4--2.0 kPa
    Per-minute ventilation volume alarm
        
    upper limit setting range   3.0--30L/min
    low limit setting range 1.0--10L/min
    Sustained high-pressure alarm
        
    it will give alarm when stress have consistently
    been higher than 2.5 kPa
    Suffocation alarm
        
    it will give sound and light alarm if there is no tidal volume input in 15s
    Power alarm
    Power
        
    AC 220V±10%     50Hz±1Hz


    Company: ARI Medical Equipment Co.,Ltd
  • AR-321 Anesthesia Machine

    Main body
        
    High-strength engineering plastic rack, light,beautiful and corrosion resistant
    Scope of application
        
    adult, child
    Gas source
        
    O2: 0.27--0.55MPa
    Flow meter
        
    O2: 0.1--2L/min    2.5--10L/min
    Flow rate of rapid oxygen supply
        
    25--75L/min
    Low oxygen pressure alarm
        
    There will be sound alarm when the oxygen
    pressure < 0.2MPa
    Vaporizer
        
    it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0--5 vol%.
    Among Halothane, Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer.
    Respiratory circuit
        
    working mode: all-close, semi-close, semi-open releasing pressure: 0.5--7 kPa
    Respiratory bellows
        
    bellows for adults, bellows for children tidal volume range:0--1500 ml
    Ventilator
    Display mode
        
    High-definition 4.8” LCD screen display
    Ventilation mode
        
    IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate)
    Ventilation parameters
        
    Tidal volume         50--1500ml
    Rate                2--99 bpm
    SIMV rate                2--20 bpm
    I:E                2:1--1:8
    Inspiratory trigger pressure -1.0--2.0 kPa
    Pressure range        1.0--6.0 kPa
     
    Parameters for ventilation monitoring
        
    tidal volume, ventilation volume, IPPV rate, I/E, peak pressure of airway, inspiratory trigger pressure, pressure - time waveform
    Security Alarm System
    Airway pressure alarm
        
    upper limit setting range 1.0--6.0 kPa
    low limit setting range    0.4--2.0 kPa
    Per-minute ventilation volume alarm
        
    upper limit setting range   3.0--30L/min
    low limit setting range 1.0--10L/min
    Sustained high-pressure alarm
        
    it will give alarm when stress have consistently
    been higher than 2.5 kPa
    Suffocation alarm
        
    it will give sound and light alarm if there is no tidal volume input in 15s
    Power alarm
    Power
        
    AC 220V±10%     50Hz±1Hz


    Company: ARI Medical Equipment Co.,Ltd
  • TPR-4000 Computerized Multi-Functional Ventilator
    TPR-4000 computerized multi-functional ventilator adopts advanced pressure flow sensor developed by American famous manufacture, electrocircuit, chip, pneumatic package produced by FOST in Germany, circular system of AMS in Japan, and CAD. It is a top –grade ventilator with technical advanced, high perform price ratio, high reliability.
     
    FEATURE
    A.      Controlled volume ventilation,synchronous triggering mode.
    B.      Eight ventilation modes for controlled volume ventilation.
    C.     Perfect computerized monitor for ventilating parameters and display for presetting number.
    D.     Comprehhensive setting and display of alarm/
    E.      Adjustment system for respiratory gas and oxygen concentration inspiration gas and chronograph.
    F.      The sensors are made in America,German and Japan with high quality and high reliability.
    G.     Comprehensive clinical ventilation function,intuitively easy to operate.
     
    SPECIFICATIONS
    Frequency(IPPV): 6 60 breaths/min
    I/E ratio:1:1,1:3
    Tidal volume:1001500ml
    Inspiratory pause:00.5s
    SIGH:Sigh is added once per 100 breaths of respiration and its tidal volume is 1.5 times as much high as that of the ventilation.
    Synchronous sensivity:-2-0.1pa
    Maximum minute ventilation volume:≥18L
    PEEP/CPAP:0.11.0pa
    Display of airway pressure:-26KPa
    Output oxygen concentration:40%76% adjustable
    Inspiration time:0.82s
    IPPV inspiration flow:0.11.5L/s
    Alarm for upper-limitation of airway pressure:1.06.0KPa
    Alarm for lower-limitation of airway pressure:02.0KPa
    Switching time between synchronization and control mode:6s
    SIMV frequency:115breaths/min
    Ventilation modes:Inspiratory pause,IPPV,IPPB,SIMV,PEEP,CPAP,IPPV+SIGH,First-aid ventilation

    Company:  Jiangxi TELI Anaesthesia & Respiration Equipment Co., Ltd.
  • TKR-200 High-Frequency Jet Ventilaotr
    A kind of opening high and normal-frequency jet ventilator with pressure regulating and time circle form. Its principle is: under the airway opening state, using high pressure gas power (O2 or compressive air) and high gas flow, rhythmically jet gas into airway through an electronic automatically controlled route, to expand the long for gas exchange.
     
    Feature:
    A. Two ventilation modes: High-Frequency Jet Ventilation (HFJV) and Continuous Positive Airway Pressure (CPAP).
    B. ABS engineering plastic cabinet and good looking PVC panel.
    C. Multiform ventilation modes and alarm function, its convenient operation is suitable for medium or minitype hospital and rural hospital.

    Specifications:
    Frequency: 8
    150 breaths/min
    I/E ratio: 1:1
    1:3 and inverse ratio
    Driving Pressure: 0
    0.30MPa
    CPAP: 0.1
    0.8 KPa
    Maximum Oxygen Concentration: 85%
    Alarm: Alarm with light and sound when no power and it will last more than 120 seconds; or alarm when no oxygen for 6 seconds.
    Humidifying Rate: 015ml/h
    Pressure Regulator Limit: 0.35MPa
    Ventilation Modes: HFJV (High Frequency Jet Ventilation); CPAP (Continuous positive airway pressure),Manual ventilation.

    Company:  Jiangxi TELI Anaesthesia & Respiration Equipment Co., Ltd.