  • Semi Auto biochemistry Analyzer SB251

    Technical Specification-Method:
    Kinetic, End-point, Linearity end-point, Non-linearity end-point, Absorbency, Sample blank, Multi-standards, Velocity, Calculation, Fixed ime, bichromatic etc.

    Wavelength Range
    •6 wavelengths optic system avoiding outer disturbance,
    • Wavelength range: 340 nm-700 nm;
    • Filter Wavelengths: 340 ,405,492,510,546,578,630nm + 2 free positionQuality control
    • Quality control for all tests,
    • Statistic and print quality control parameters automatically with QC curves;
    •Program: Add or delete test items easily according to the condition, modify the test parameters;
    • Display Dynamic curves at real time, visually react the process with kinetic Delta;
    • Dormant automatically for the lamp to prolong it¡¯s lifespan;
    • Input 8 standard curves at most in testing with multi-standard method;
    • Open reagent;
       Peristatic pump, built in printer.
       Dual cuvette operation (flow through & manual)

    Specifications
    • Test items: ¨R250
    • Flow cell: quartz flow cell 32uL
    • With both shipping and cuvette system
    • Lamp: 6V 10W
    • Measurement range: 0~2.5Abs


    Company: SINDURI BIOTEC
  • XD600 Electrolyte Analyzer Series
    We are best brand in China to make electrolyte analyzer. We have started it since year 1993. Now we have more than 20000 users.

    XD 683 Potassium, Sodium, Chloride Analyzer
    XD 684 Potassium, Sodium, Chloride, Lithium Analyzer
    XD 685 Potassium, Sodium, Chloride, Calcium/pH Analyzer
    XD 687 Potassium, Sodium, Chloride, Total Carbon Dioxide Analyzer
    XD 680 Automatic sampler (optional)

    We are best brand in China to manufacture electrolyte analyzer. We have started it since year 1993. Now we have more than 20000 users in China. The XD600 electrolyte analyzer series adopt the ion-selective electrode technology. And they are automatically controlled by the computer. They can fast, accurately and reliably test K+, Na +, Cl-, Li+, iCa++, nCa++, pH and TCO2 in the biological sample. It can also calculate the value of anion gap (AG). The XD600 electrolyte analyzer series are convenient and practical clinical testing instrument.

    1. It employs the microprocessor technology. The working of the instrument is completely controlled by the computer program.
    2. It has the liquid crystal big screen display. The users can interact with the machine directly. The whole operating process is quite simple.
    3. It has automatic air bubble examining function. The accuracy of the examination is guaranteed. The instrument can be 24 hours power on, and will be automatically in the sleeping mode if there is no testing in 10 minutes.
    4. Sample-entering plate is optional. One plate contents 40 sample positions.
    5. Automatic two-point calibration, multi-point quality-control and outside scale modification programs, quality-control program: It can set up 1-3 quality-control samples, calculate the value of X, SD and CV%, and print out 30 days quality-control chart.
    6. It can store 2000 testing results.


    K: 0.50-15.0 mmol/L, 0.01 mmol/L., CV≤1.0%

    Na: 30.0-200.0 mmol/L, 0.1 mmol/L, CV≤1.0%

    Cl: 30.0-200.0 mmol/L, 0.1 mmol/L, CV≤1.0%

    Ca: 0.10-5.00 mmol/L, 0.01 mmol/L, CV≤1.0%

    Li: 0.10-5.00 mmol/L, 0.01 mmol/L, CV≤3.0%

    TCO2: 5.0-60.0 mmol/L, 0.1 mmol/L, CV≤4.0%

    pH: 6.00-9.00, 0.01, CV≤1.0%

    Measuring time≤60 Seconds (including absorbing the sample, washing and printing time)

    *  Sample volume: 120uL Minimum 65uL

    *  Sample types: Plasma, serum, whole blood, diluted urine (only measuring K+, Na+, Cl--)

    *  Data output: Liquid crystal display (LCD), imbedded printer; RS232 interface can be connected with the exterior computer.

    *  Working environment: Temperature 5-40, Relative humidity ≤80%

    *  Power supply: AC220V±10%, 50Hz, 60VA

    *  Dimension: 420mm× 360mm× 270mm

    *  Weight: 11kg(host machine)



    Company: Shanghai Xunda Medical Instrument Co., Ltd.
  • DSI 900 Electrolyte Analyzer Series

    We are No. 1 brand in China to make electrolyte analyzer. We have started it since year 1993. Now we have more than 20000 users.

    DSI 903B Electrolyte Analyzer: test Potassium, Sodium, Chloride
    DSI 905 Electrolyte Analyzer: test Potassium, Sodium, Chloride, Calcium, pH
    DSI 907 Total Carbon Dioxide Analyzer: test total CO2

    We are No. 1 brand in China to manufacture electrolyte analyzer. We have started it since year 1993. Now we have more than 20000 users in China. The DSI 900 Electrolyte Analyzer introduces international advanced ion-selective electrode technology. It is able to test the potassium (K+), Sodium (Na+), Chloride (Cl-), ionized calcium (iCa++), standardized ionized Calcium (nCa++), pH and TCO2 with Reliability, practicality and convenience.

    1. It uses the microprocessor technology. The working-procedure of the instrument is completely controlled by the software.
    2. Big LCD display. Users friendly and interactive operating interface. Extremely simple operating procedure.
    3. It takes 25 seconds from absorbing the sample to showing the results. The results are displayed in unit of mmol/L.
    4. Transparent testing cavity makes it easy to remove the air bubbles or the blood clots.
    5. 24 hours continuously power on. It will automatically calibrate every 2 hours. Samples are ready to test.
    6. It has quality-control programs to satisfy the QC standards of different locals. It can also carry on the quality-control data processing, and calculate the mean values of X, SD and CV.
    7. Testing results can both be shown on the LCD, and be printed out in the form of testing report by the internal printer.
    8. The instrument has RS-232 standard interface and can be connected with exterior computers.
    9. It can store sample test data and conveniently query.

    K:  0.50-9.99 mmol/L, CV≤1.0%
    Na: 80.0-200.0 mmol/L, CV≤1.0%
    Cl: 50.0-200.0 mmol/L, CV≤1.0%
    Ca: 0.10-4.00 mmol/L, CV≤1.0%
    pH: 6.50-8.50, CV≤1.0%
    TCO2: 3.0-60.0 mmol/L, ≤3.0%

    *  Sample volume: Sample volume 100μL; Calibrating solution CAL150μL; Slope solution 150μL; Washing solution 450μL

    *  Sample types: Plasma, serum, whole blood, etc.

    *  Working environment: Temperature 5-40, Relative humidity 10-93%

    *  Power supply: AC220V±10%, 50Hz, 60VA
    *  Dimension: 377mm×230mm×287mm
    *  Weight: 7kg(host machine)


    Company: Shanghai Xunda Medical Instrument Co., Ltd.
  • ESR-30 Automatic Erythrocyte Sedimentation Rate Dynamic Analyzer
    ESR-30 can test 30 samples at the same time. The user can add a sample to the analyzer at any time.

    ESR-30 Automatic Erythrocyte Sedimentation Rate (ESR) Dynamic Analyzer introduces the photoelectricity technology. It will regularly scan and exam the positions of the red blood cells and the interface of the blood plasma, which is automatically controlled by the microcomputer. After processing by the microcomputer, the data will directly be displayed on the large LCD screen, and can also be printed out in the forms of ESR results and ESR curves by the built-in printer.

    It's capable of storing 150 sample results and curves. ESR-30 offers a simple safe economical and highly accurate method for performing ESR determination. Sample is ready to test. It's very easy and convenient. The testing result of the ESR-30 automatic ESR Dynamic Analyzer can work perfectly without the disturbance of icterus, hemolysis, chyle and other pathological samples and without the bad effect of the external factors. It's compatible to Weis method.

    Erythrocyte Sedimentation Rate (ESR) is determined by measuring in millimeter per hour, the distance red blood cells have fallen after separating from plasma in a vertical test tube.

    *Measuring principles: Infrared ray preventing law
    *Measuring time: 30 minutes/ 60 minutes (Optional)
    *Accuracy: ±2mm/h(ESR≤30mm/h)
    ±3mm/h(ESR30-80mm/h)
    ±5mm/h(ESR>80mm/h)
    *Sample volume: 1.6ml concretion resisting whole blood
    *Number of samples simultaneously measured: 30
    *Working environment: Temperature: 10-30,Relative humidity: ≤80%
    *Power: AC 220V±10%, 50Hz
    *Data interface: RS-232
    *Dimension: 425×300×185mm
    *Weight: 10kg (Host machine)

    Company: Shanghai Xunda Medical Instrument Co., Ltd.
  • JXJ-402B Fully Automatic Laser Blood Cell Counter

    JXJ-402B represents a totally brand new and innovative concept of 3-part-differential blood cell counters.

    JXJ-402B Fully Automatic Laser Blood Cell Counter represents a totally brand new and innovative concept of 3-part-differential blood cell counters. It is adopted the most advanced technology of COULTER Volume Analysis and Flow Cytometry.

    With only a blob of blood (mere 20 µl), JXJ-402B takes just approx. 40 seconds to give a reliable complete blood result with 18 parameters and 3 histograms for an amazingly tiny price.Dilute the blood sample with ordinary physiological saline directly, no need of special reagent. Lower the cost to the utmost extent.

    *Available parameters: PLT, RBC, HGB, HCT, MCV, MCH, MCHC, WBC, LYM%, GRA%, MID%, LYM#, GRA#, MID#, RDW, MPV, PCT, PDW

    *Measure precision:
    Para. CV Value Precision
    RBC ≤2% ±6(3.00-6.00×1012/-L)
    WBC ≤3.5% ±10(4.00-12.00×109/-L)
    PLT ≤3.5% ±10(50-220×109/-L)
    HGB ≤1.5% ±(3+3×C) L(50-200g/L)
    *  Sample volume: 20 µl whole blood
    *  Diluent: Physiological saline directly, no need of special reagent.
    *  Testing speed: 50-100 test/hour
    *  Laser Scatter and Sheath Flow technology is used, no problem of jamming
    *  Dimension: 460×325×310mm
    *  Weight: 17kg
    *  Power supply: 220V, 50HZ, 60W
    *  Display and print out automatically.
    *  Can be connected to PC with standard RS-232C
    *  Extremely easy to use, user-free maintenance


    Company: Shanghai Xunda Medical Instrument Co., Ltd.
  • SUNY-500 Urine Analyzer

    It can detect the urine strip and print out the analysis report automatically, accurately, and efficiently.

    SUNY-500 Urine Analyzer depends on cold light source refection determination principle with super high luminosity, it can be connected with urine sediment station and communicate with computers, with an internal thermal printer. It can calibrate automatically and eliminate the influence of pH, specific gravity and colors of the urine under testing. It has big screen and good interface between the instrument and operator.

    The analyzer has infrared to detect the urine strip and starts to test automatically. Close system collects the tested urine strip automatically. The printer can feed the paper automatically.

    The Technological Specifications and Features
    Ø Test Item : URO, BIL KET, BLD, PRO, NIT, LEU, GLU, SG, pH, VC
    Ø Test Principle : Reflectance method of photoelectric color comparative
    Ø Measurable Test Strips : Reagent strips for Urinalysis
    Ø Test Speed : 540 strips/hour
    Ø Memory Capacity : 1000results
    Ø Screen : 6.4 inch touch screen, Electro Luminescent Display
    Ø External Output : RS-232 interface
    Ø Languages : Chinese, English
    Ø Supply : AC220±22V, 50Hz-60Hz
    Ø Printer : Built-in thermal printer
    Ø Operating Temperature : 18-30oC

    Ø Optimum Temperature : 20-25oC

    Ø Operating Humidity : ≤80%

    Ø Weight : 6.5Kg

    Ø Dimensions : 340mm x 330mm x 290mm


    Company: Shanghai Xunda Medical Instrument Co., Ltd.
  • OP-155 Automated Urine Analyzer
    OP-155 Automated Urine Analyzer is our newly developed intellectualized product aimed at improving the health of human life following our other market-proven products.

    OP-155 includes the leading optical test system, good anti-interference and ingenious design, new style, nicety, facility, economy, quickness, precise, printing out, high processing rate of 120 samples per hour and 1000 ROM memory space.

    The Technological Specifications and Features
    Ø Testing parameters include:
    Leukocytes, Urobilinogen, Bilirubin, Nitrite, pH, Specific Gravity, Blood, Glucose, Protein, Ketone, Ascorbic Acid
    Ø RGB tricolor test principle, high anti-interference and adaptability
    Ø Super-high lightness LED white light resource, 45 degree reflection, improving SNR
    Ø Wavelength:470nm, 540nm, 620nm
    Ø Quasi 32 bit RISC SCM designed, high reliability
    Ø Testing speed: 120 test/hour (Continuous test); 60 test/hour (Single-step test)
    Ø Data Base memory: FalshROM, up to 1000 test results, managing according to date and projects
    Ø Fully integrated hardware and software, humanized interface, easy to use
    Ø Automatic waste absorption to prevent cross-contamination
    Ø Standard RS-232C DB9 male outlet, which can be connected to PC
    Ø Qualitative guideline, quantitative data result, viewing, printing, and many modes of printing are available.
    Ø Printer: 57mm built-in thermal printer
    Ø Environment requirement: 15~30; RH 70%
    Ø Power Source: AC220V (±10%), 50Hz (±10%), 110V(±10%), 60Hz (±10%)
    Ø Power: 40W
    Ø Net weight: 3.0kg
    Ø Volume: 253×237×171mm

    Company: Shanghai Xunda Medical Instrument Co., Ltd.
  • S8/S8+ Emergency Biomedical Analyzer
    Within 6 minutes, it can finish test of 8 biochemistry & 3 electrolyte parameters. It is especially used for emergency lab.

    *  National key new product: National practical new-model patent numberZL02261480.X Innovation Fund Item by Ministry of Science and Technology of the P. R. China High and New technology transformed into products achievement of Shanghai

    S8+ Emergency Biomedical Analyzer combines electrolyte analyzer and biochemistry analyzer. This is our unique technology even across the world. No other company makes this type analyzer. Its test speed is very fast. Within 6 minute, it can finish the test of 8 parameters of biochemistry and 3 parameters of electrolyte.
    It is especially used for emergency lab. S8+ can test any combination of 8 parameters from total 17 parameters (GLUGOD, GLUCK, ALB, TP, UA, T-Bil, AMY, ALP, GGT, ALT, AST, CK-NAC, CK-MB, LDH, HBDH, BUN, Cr). If 8 parameters are not necessary, you can pick any parameters out.

    S8+ Emergency Biomedical Analyzer just needs 300 μl of sample volume. Then the sample will be dispatched to 8 flow cells and mixed with reagents according to different ratio. How to dispatch and mix is a patent of our company. Then 8 detectors will measure the absorbance. At the same time, the sample will be sent to the electrode to measure the K, Na and Cl parameters. All procedure will be completed within 6 minutes.

    *  High efficiency: It can simultaneously report 11 testing results within 5 minutes.

    *  Low cost: It doesnt need special biochemical reagent, so the analytic cost is greatly reduced.

    *  High precision: By using the wet chemical process, testing precision is guaranteed.

    *  Easy to operate: Once samples enter, analysis carries out automatically. Equipped with keyboard and mouse, friendly English dialogue windows.

    *  Reagent refrigerating function: temperature in the safe: 4-10.

    *  The function of automatically self-identifying sample and reagent shortage.

    *  It can be in power-save mode for 24 hours. And it can also self-identify whether the reagent is valid or not.

    *  Function of self-identifying the air bubble: During the process of absorbing the sample, it will self-detect if there are air bubbles in the pipeline.

    *  Self-diagnosis function: keyboard diagnosis, light source diagnosis, filter localization diagnosis and electrode diagnosis.

    *  Automatic data maintenance against power failure.
     
    *  Automatic two points calibration, can reserve and query.

    *  Quality-control function: It can make statistical analysis, save and make quality-control graph, based on the quality-control data.

    *  Archives management: Its equipped with small size archives libraries. It meets the modern management needs of the clients.

    *  Testing method: Biochemical parts: end-point method, two-point method, speed method; Electrolyte parts: ion-selective electrode.
     
    *  Sample volume: Biochemical item: 200μl; Electrolyte: 100μl.

    *  Sample type: serum, plasma.

    *  Reagent volume: approximately 240μl.

    *  Flexible testing item: Customers can flexibly make changes to the 8 biochemical items, and choose any of them to test.

    *  Measure method: End point, two point, velocity, etc.

    *  Optic system: 8 channels filters

    *  Light source: Long life halogen lamp 6V/20W

    *  Wavelength range: 340-700nm Wavelength choosing

    *  Intervening lights filter: 340, 405, 510, 545, 600 nm (for standard equipment, 380, 690 nm for option)

    *  Photometric range: 0.000-2.500A

    *  Resolution: 0.001A

    *  Precision: CV≤1.0%

    *  Refrigerator temperature: 4-10

    *  Precision of the temperature control: SD≤0.2

    *  Sample volume: 200μl serum or plasma

    *  Reagent volume: ~240μl/item

    *  Flow cell: Temperature control flow cell array (37)

    *  Receiver: Silicon light cell array

    *  Monitor: 15 inch color LCD monitor

    *  Printer: Printer provided

    *  Communication: RS232C communication interface

    *  Power supply: 220V±10%;50Hz±2%

    *  Dimension: 565×470×525mm

    *  Weight: ≤26.5Kg

    S8+ electrolyte parts (optional)

    K: 0.50-15.0mmol/L, 0.01mmol/L

    CV≤1.0%

    *  Ion-selective electrode

    *  100 μl serum or plasma

    Na: 30.0-200.0mmol/L, 0.1mmol/L

    Cl: 30.0-200.0mmol/L, 0.1mmol/L



    Company: Shanghai Xunda Medical Instrument Co., Ltd.
  • XD811F 4 Channels Fast Clinical Chemistry Analyzer
    XD 811F has four channels and can test 4 samples at the same time. It is very useful and quick to test samples in batches.

    XD 811F 4 Channels Fast Clinical Chemistry Analyzer. XD 811F has four channels and can test 4 samples at the same time. It is very useful and quick to test samples in batches. Surely, it gives live display of the reaction for all 4 samples.

    1. Significant break-through in the biochemical examination technology
    2. International Innovation-flow cell array
    3. The national patent-aspherical lens distributed beams

    *Friendly English dialogue windows
    *Integrated testing methods
    *Nimble calibration ways
    *Convenient sample determination
    *Direct viewing dynamic display
    *Formidable information storage capability
    *Consummative printing format
    *Reliable power restoration after power failure

    * Measuring Channels
    *  4 Determination methods
    End-point method, Two-point method, dynamic method, dual wavelengths method, Sample vacant method
    *  Calibration method
    Seven standard curves: linear method, folded line method, quadratic curve method, cubic curve method, divided logarithm equation method, cubic spline function method, 3. 4-parameter functions
    *  Item storage
    It has a capability of storing 100 testing items and 20 computational items
    *  Data storage
    Magnanimous storage of testing results
    *  Real-time quality-control
    It can establish 2 quality-control specimens for each testing items, and can also display or print out the statistical data and chart of the 30 days quality-control process
    *  Printing function
    Chinese language inputs of the patients information, as well as printing out the complete and comprehensive bio-chemical testing results
    *  Light source
    6V 20W halogen tungsten lamp
    *  Wavelength choices
    *  Wavelength range:340-700 nm; Spectrum band width ≤ 12nm
    *  Basic disposition: 340/405/492/510/545/578/630 nm
    *  Two optional wavelengths to choose from the 4 choices: 380/450/650/690 nm
    *  Display: 0.001AInternal Computer:0.0001A
    *  Precision
    CV≤1.0%
    *  Monitor
    15" color monitor
    *  Key board
    16 Thin-film light-touch keys, mouse
    *  Hard disc
    40G or above 40G capability
    *  Interface
    UBS/Communication/Print
    *  Printer
    Peripheral 80 parallel port point-array printer
    *  Power
    AC 220V/50Hz , 250VA
    *  Size
    450mm×420mm×280mm
    *  Weight
    18kg

    Company: Shanghai Xunda Medical Instrument Co., Ltd.
  • Biochemistry Analyzer

    It is newly developed by adopting up-to-date and advanced concave grating technology.It is a very good machine with low price.

    XD 811G Biochemistry Analyzer culminates the biochemistry analysis by accumulating more than 10 years experience in researching, developing and marketing biochemistry analyzer.

    It is newly developed by adopting up-to-date and advanced technology. High performance of each main part, newest software and advanced microcomputer technology enable the machine stable, fast, and extremely easy to use.

    *  Adopting advance photometric technology to enable the wavelength to be adjusted subtly and continuously at the nanometer level
    *  Super performance for programs and data processing and storage
    *  Wide voltage range design for power supply and running under low voltage
    *  Culminate the machine by integrating more than 10 years experience in researching, developing and marketing the biochemistry analyzer
    *  Advanced photometric technology: adopting concave grating as the spectrometer, wavelength is adjustable continuously, very small wavelength deviation, high optical performance
    *  Advance data processing technology: built-in microcomputer controls the whole test and processes all spectrum data
    *  Full scale display function: large LCD screen with backlight to display characters and curves, adjustable visual angle, man-machine dialogue interface, extremely easy for use
    *  Various test methods: endpoint, two points, kinetics, dual wavelength, etc.
    *  Reliable calibration ability: 1-6 points standard curve setup function, either linear or non-linear calibration is optional
    *  Powerful data processing ability: both test item setup and reagent parameter setup are open, over 200 test items can be edited and stored
    *  Super data storage capacity: timeless storage of test result, store and display the QC chart, curve and data within 31 days
    *  Flexible result output: several models to print test report, QC report and curve; search function for historical data
    *  Good adaptability: wide voltage range design for power supply, applicable in low voltage region
    *  Excellent potential for function extend: RS-232 interface to communicate with external computer; PLUS software (optional) provided by our company for function extend make the analyzer more powerful
    *  Light path: Grating spectrometer system
    *  Wavelength range: 330-800nm
    *  Light source lamp: 12V Quartz Tungsten Halogen Lamp, long lifetime
    *  Wavelength selection: 1nm adjustable continuously
    *  Wavelength accuracy: ±2nm
    *  Wavelength repeatability: ≤1nm
    *  Absorbance measure range: 0.000-2.500A

    *  Display: 0.001A; Internal calculation: 0.0001A

    *  Precision: CV≤0.5%

    *  Cross contamination: ≤1.0%

    *  Sample volume: 200-2000μL, adjustable

    *  Cuvette system: Special stainless steel micro flow cell, 32μL

    *  Display: Large LCD screen with backlight, adjustable visual angle

    *  Temperature control: 25, 30, 37, room temperature, temperature accuracy: ±0.1

    *  Data processing: program≥200, having function of operation prompt, system self-checking, malfunction prompt, etc
    *  Test method: Endpoint, standard curve, two points, kinetics, single/dual wavelength, absorbance, sample blank, etc.
    *  Keyboard: 18 light-touch keys
    *  Communication: RS-232 interface
    *  Power supply: AC 100-240V, 50Hz ±1Hz
    *  Dimension: 460×390×228cm
    *  Weight: <11kg


    Company: Shanghai Xunda Medical Instrument Co., Ltd.