Ventilator trade,Ventilator offer, Sell leads
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
Select to
Page 1 of 4
  • TKR-400A computerized high-frequency ventilator for infant
    It is a ventilation device for infant with novel structure and good performance, and chooses opening ventilation mode with high frequency and little tidle volume, so the airway pressure is low.
    A. The tidal air can letout with constant pressure, constant current or accurately adjustable flow.

    B. Opening ventilation, opening intubation makes it not need casing bag, little resistance as expiration is suited for the ventilation management of infant.

    C. Evident effectiveness of treating ARDS can be shown with inserting small tube and jetting oxygen through nasal vestibule, which is secure and doesn't cause pressure wound easily.

    D. PEEP and humidifier volume can be adjusted accurately.

    E. Alarm system with sound and light when no oxygen, poor of electric quantity or low airway positive pressure.

    F. Heated humidifier can be used for good effectiveness of humidifying.

    G. Accumulator jar, it can be used while being charged and can last for more than four hours.



    Specifications:

    Frequency:10~150 breaths/min

    I/E ratio:1:1,1:1.5~ 1:3 and inverse ratio

    Driving Pressure :0~60KPa 

    Pressure Atomizer Rate:>=6ml/h

    Process Ventilation:T=10min,

    ProI: f(150):f(35)=7:3

    ProII: f(35):f(150)=7:3

    Storage Battery:4Ah, Automatic charge when 12V

    SIGH:3breaths/min

    Alarm:Alarm when battery voltage is lower than 11V, alarm lasts 6 seconds if no oxygen, Alarm with audible signals and flashing light when the airway pressure is over 0.8KPa

    CPAP:0~0.5KPa 

    PEEP:0~0.20KPa

    Oxygen Concentration Adjustable:21%-90%

    Jetting volume range:O~600ml/time

    Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure);HFJV+PEEP(Positive End-Expiratory Pressure), HFJV+SIGH(Sigh), Process ventilation I and Process ventilation II, Manual Control Mode.

    Company: Ternary Anaesthesia & Respiration Equipment Co. Ltd.
  • TPR-4000 computerized multi-functional ventilator
    Feature:
    A. Ventilation modes:Controlled volume and synchronous touching sensitivity.
    B. Eight ventilation modes for controlled volume ventilation.
    C. Perfect computerized monitor for ventilating parameters and display for presetting number.
    D. Comprehensive setting and display of alarm value.
    E. Adjustment system for respiratory gas and oxygen concentration and humidifier with constant temperature inspiration gas and timer.
    F. The sensors are made in America, German and Japan with high quality and high reliability.
    G. Comprehensive clinical ventilation function and friendly operation.

    Specifications:

    Frequency:(IPPV)6~60 breath/min

    I/E ratio:1 : 1~ 1 : 3

    Tidal volume :100~1500ml

    Inspiration pause:O~0 .5s、with five gears

    SIGH:Sigh is added once per 100 breaths of respiration and its tidal volume is 1.5 times as much high as that of the general ventilation

    Synchronous sensitivity :-2~-0.1KPa

    CPAP/PEEP:O~2KPa

    Display of airway pressure:-2~6KPa

    Minute volume:0~30L

    Concentration of inspiration gas and oxygen:40%~76% adjustable

    Display of inspiration time:0.2~9.9s

    IPPV inspiration flux:0.1~1.5L/s

    Intermittent command ventilation frequency:1~15 breaths/min

    Alarm for upper-limitation of airway pressure:1.0~6.0KPa

    Alarm for lower-limitation of airway pressure:0~2.0KPa

    Switching time between synchronization and control mode:6s

    Ventilation modes:Inspiration pause, CPAP, IPPV, IPPB,PEEP,SIMV, IPPV+SIGH, First-aid ventilation

    Company: Ternary Anaesthesia & Respiration Equipment Co. Ltd.
  • TKR-500 computerized high-frequency two-sided lung ventilator
    TKR-500 computerized high-frequency two-sided lung ventilator is a specified device for thorax department, lung department, narcosis department and is often used for respiration management and treatment of special patient.
    A. Two-loop ventilation system controlled by computer.
    B. In-phase ventilation can be carreed on to the two-sided lung (ill lung or healthy lung) through separation ventilation, and also anti-phase ventilation management and ventilation tretment.
    C. Two-humidifying-loop can humidify and antibacterial treatment respectively.
    D. Good quality humidifier adaptor gaining national patent is used for heating or ultrasonic humidifying conveniently.
    E. Two-loop with monitoring parameter including ventilation frequency, Sigh and Driving pressure also can alarm when no power or oxygen lack.

    Specifications:
    Frequency:10~150 breaths/min

    I/E ratio:1 : 1~ 1 : 3 and inverse ratio

    Driving Pressure:0~0.15MPa 

    Humidity rate:no less than 10ml/h

    Alarm:Alarm with light and sound for no power, lasting 6 seconds if no oxygen

    CPAP:not less than 1.0KPa

    PEEP:0~0.5KPa

    Jetting volume range: 0~1400ml /time

    Pressure Regulator Limit:0.03MPa

    Ventilation Mode: HFJV (High Frequency Jet Ventilation);CPAP (Continuous positive airway pressure);ProI and ProII ventilation;control+SIGH;HFJV+PEEP ventilation and so on

    Company: Ternary Anaesthesia & Respiration Equipment Co. Ltd.
  • TKR-400T computerized multi-function high-frequency ventilator
    Feature:
    A. HF JV(High-frequency jet ventilation) with pressure support, which can supply the higher inspiration pressure so that the patients can inspire sufficient oxygen with a wet finger.
    B. Opening airway. The ventilation can be made with high frequency and little tidal volume and low airway pressure, which is good to increase the blood oxygen density.

    C. Ventilation mode through nasal vestibule without effect which can avoid from tracheotomy and endotracheal tube so as to decrease patient's pain and the effectiveness of oxygen feeding is very good, The patient can talk, drink and eat, when ventilating.

    D. Continuous positive airway pressure with adjustable oxygen density plus effective humidifier can show the feature of CPAP better.

    E. The multi-functional humidifier adaptor can be connected with any type of humidifier by trachea intubation of national or international standard.

    F. The pressure humidifier has knob to manipulate the air volume and has the delicacy alarm with sound and light for no power or gas.



    Specifications:

    Frequency:10~150 breaths/min

    I/E ratio:1 : 1~ 1 : 4 and inverse ratio

    Driving Pressure :0~0.15MPa 

    Process Ventilation:T=10min,

    ProI: f(150):f(35)=7:3

    ProII: f(35):f(150)=7:3

    SIGH:3,6,9breaths/min

    Alarm:Alarm with light and sound for no power and gas, lasting 6 seconds if no oxygen

    CPAP:not less than 1.0kPa

    PEEP:not less than 0.5kPa

    Oxygen Concentration Adjustable:40%-90% displayable

    Jetting volume range:O~1400ml/time

    Pressure Regulator Limit:0.03MPa

    Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure);ProI and ProII ventilation; HFJV+PEEP ventilation and so on

    Company: Ternary Anaesthesia & Respiration Equipment Co. Ltd.
  • TKR-300CG computerized supply oxygen for efflux
    Feature:
    A. The device adopts impulse jet oxygen feeding technique with great flow rate of oxygen feeding in a shot while, when feeding oxygen, it adopts change mode major in reflux and many kinds of gas flow mechanism such as convection, laminar flow, sheet flow and so on concurrently, which is good to increase partial pressure of oxygen rapidly, At the same time fluctuation of thorax caused by increasing oxygen flow into airway is good to let out CO2.
    B. Jet oxygen feeding is supported by pressure when inspiration and secure certain PEEP effect when feeding oxygen, So as to reach good effectiveness of oxygen feeding.
    C. Accumulator jar, it can be used while being charged and can last for four hours after having been charged.
    D. Alarm system with sound and light when lack of electric quantity or airway pressure.
    E. 300CG chooses digital display of import pressure sensor.
    F. 300CG has three kinds of airway limited pressure alarm for adult, child and infant.
    G. The device disposes pressure humidifier which has good humidigying effectiveness.

    Specifications:
    Power supply:AC220V±22V 50HZ±1HZ
    I/E ratio:1:1,1:1.5~ 1:3 and 3:1
    Driving Pressure :0~0.15MPa 
    SIGH:6breaths/min, I/E=1:4
    Pressure Regulator Limit:0.30MPa
    CPAP:not less than 1KPa 
    Oxygen Concentration Adjustable:40%-90%
    Process Ventilation:T=10min,Infinite recursion
    ProI: f(150):f(35)=7:3
    ProII: f(35):f(150)=7:3
    Alarm:Alarm with light and sound for no gas or no power or airway pressure is over
    Inner Battery:4Ah 12V
    Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure),HFJV+SIGH(Sigh); Process ventilation I and Process ventilation II, Manual Control Mode.

    Company: Ternary Anaesthesia & Respiration Equipment Co. Ltd.
  • TKR-300B computerized high-frequency jet ventilator
    TKR-300B computerized jet ventilator is a normal ventilating device with the best performance and being widely used in clinical among the same grade high-frequency ventilators.
    A. Process ventilation modes controlled by computer, it is good to increase partial pressure of oxygen and decrease the reserve of CO2.
    B. Digital display adjusted by lightly triggering of frequency. The adjustable range of I/E is wide, with reciprocity function.
    C. Multi-funttional humidifier adaptor saits for connection of ISO and national standard is disposed, The humidifier device si conveniently connected to the main frame.

    Specifications:
    Frequency:10~150 breaths/min
    I/E ratio:1:1,1:1.5~1:5 and inverse ratio
    SIGH:6breaths/min, I/E=1:4
    Driving Pressure :0~0.30MPa 
    Pressure Regulator Limit:0.35MPa
    Most jetting volume:1400ml/time
    CPAP:≥1.5KPa 
    Oxygen Concentration Adjustable:40%-90%
    Pressure Atomizer Rate:≥10ml/h
    Process Ventilation:T=10min,I/E=1:1.5,f(150):f(35)=7:3,infinite cycle
    Depressing frequency:start from 60breathmin, and then depress the frequency one time every 1 minute till down to 10breaths/min
    Alarm:Alarm with light and sound for no power or no gas
    Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure),HFJV+SIGH; Process ventilation frequency decreasing, Manual Control Mode.

    Company: Ternary Anaesthesia & Respiration Equipment Co. Ltd.
  • TKR-300JII computerized high-frequency first-aid ventilator
    It is widely used for clinical salvaging and revival also is a dedicated device used for respiration salvaging on emergency ambulance.
    A. An opening system is designed to avoid leakage of airway, When ventilating, the intubation may have no casing bag. Little tube may be used for ventilation when resistance of expiration is small, so that mucose won’t be hurt easily.
    B. Airway is open during wentilarion, suction and ventilation can be done synchronously, so good effectiveness of oxygen combination can be shown without inspiration and expiration synchronizing.
    C. Lower airway pressure is good to increase blood discharge and decrease encephal pressure.
    D. Suction device, its driving negative pressure is adjustable.
    E. Accumulator jar, it can be used continuously for not less than four hours after being charged.
    F. The system disposes completely with laryngoscope, inlet intubation, catheter of tracheotomy, nasal prongs tube, and air tube etc.

    Specifications:
    Frequency:10~150 breaths/min
    I/E ratio:1:1,1:1.5~1:3 and inverse ratio
    SIGH:6breaths/min,
    CPAP:≥1.5KPa 
    Suction negative pressure:-0.05~0MPa
    Driving Pressure :0~0.15MPa
    Constant volume ventilation: T=10min, I/E=1:1.5
    Adults:f(100):f(20)=7:3, tidal volume=550ml/time, Driving pressure=0.06MPa
    Children:f(100):f(20)=7:3, tidal volume=350ml/time, Driving pressure=0.04MPa
    Storage battery:4Ah, Automatic charge when 12V
    Most jetting volume:≥1400ML/time
    Oxygen Concentration Adjustable:40%-90%
    Alarm:Alarm when battery pressure is lower than 11V; Alarm when the oxygen pressure is lower than 0.01MPa; Alarm with sound and light when no gas
    Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure),HFJV+SIGH; Constant volume ventilation.

    Company: Ternary Anaesthesia & Respiration Equipment Co. Ltd.
  • TKR-300CG Trachea operation oxygen supply system
    Feature:
    A. This device is very suitable and necessary to facial dept. And trachea surgery dept, for clinical use, and perfectly integrates the Flux ventilator(TKR-300CG) and Trachea Foreign Bodies Operation Equipment (bronchoscope, all kinds of pliers, cool-light source, trolley included).
    B. The high-frequency ventilation theory is adopted, and can actualize the ventilation with high-frequency and little volume during trachea operation. It has advantages such as pukkah oxygen supply, low airway pressure during ventilation, and not easy to make pressure injury.
    C. Because of enough oxygen supply, can reduce the use of anaesthesia medicine, and decrease the complication, and work on a long time ventilation of operatin. Open ventilation adopted is good to trachea light byu cool-light source. Different kinds of pliers and bronchoscopes are suitable to different situation operation of patients, and also to oxygen supply of trachea operation. What's more, can fix one excellent trachea humidifying setting.
    D. Can actualize the respiratory treatment, management and resuscitator as below ventilation mode:Control ventilation, Sigh, Process Ventilation, CPAP, PEEP and Hand control mode.

    Specifications:
    Frequency:10~150 breaths/min
    I/E ratio:1:1~1:3 and inverse ratio
    Driving Pressure :0~0.15MPa
    Constant volume : 0-20L/min
    CPAP:≥2KPa 
    Pro I:Total frequency(T)=10mins,I/E=1:1.5
    T1(150breathes/min):T2(15breathes/min)=7:3
    Pro II:Total frequency(T)=10mins,I/E=1:1.5
    T1(15breathes/min):T2(150breathes/min)=7:3
    Sign:6 breathes/min, I/E=1:4
    Oxygen density adjustable:35%-90%
    PEEP:0.05-0.5KPa
    Tidal volume:0-3000ml/breath
    Inner battery: more than 4hour

    Company: Ternary Anaesthesia & Respiration Equipment Co. Ltd.
  • TPR-12 painless childbirth antalgic gas inspirator
    TQY gas source boxes for ventilator(oilless air compressor) with its main component air compressor is made by GARENS in America is an ideal gas-dupplying source for all kinds if ventilators and apparatus for humidifying treatment or gas-oxygen asmixture and so on. It adopts the meandering structure and can drain automatically with lower noise and good cooling effect. A placement flat for other apparatus is fixed on the top of the device. So ventiators or other devices can be put on it.
    A. Drain automatically without water overflowing.
    B. With long operation time and low noise.
    C. It can export oilless, clean and dry compressed air.
    D. Restart instantly after cutting power.
    E. With gas source for multiform ventilators.
    F. The main component air compressor is supplied by the professional factory GARENS in America.
    G. Output pressure:0.2-0.5MPa
    E. Equip with univesal wheel in the bottom, can move every where and have the regular valve of brake.

    TPR-12 painless childbirth antalgic gas inspirator is controlled by patients or lying-in women themselves is a gas inspiratory system used especially to ease pain.
    The patient can inbreathe the Giggle gas(which mixes N2O and O2 by a certain proportion with good and rapid analgetic effect and lower cost without side effect.
    A. Giggle gas with stable chemistry quality is a kind of narcotic with the least toxicity inhalational gas, it has no irritative effect on the respiratory organs and will not do harm to heart,liver and kidney.
    B. Giggle gas changes through property of the ionic channels by restraining the excitability of nerve center and the release of nerve delivery. Its work will be done in 30 seconds and it will disappear in a few minutes after stopping inspirating the gas.
    C. It can avoid from the aching chock of fracture, burn and other surgery.
    D. It chooses the one-off respiratory loop, which doesn't need to samitize or purge to prevent the cross infection.
    E. It is good for lying-in women to bear the childbirth painlessly with no effect on the childbearing manner. It won't restrain the fetal circulation and will not increase the bleeding and it can shorten the whole bearing course so that lying-in women can keep clear-headed to cooperate with the doctors.

    Specifications:
    Inspiration mode:Independent and synchronous inhalation with numeric flux setting in advance.
    Inner cylinder volume:10L
    Inspiration flux:10~1000ml/time
    Inspiration sensitivity:≤-0.1KPa
    Alarming for lack of gas pressure:≤0.05MPa
    Cubage of the gas bottle:10L/120kg
    Gas proportion:N2O:O2=1:1
    Reductor output pressure:0.2MPa
    Alarm with light and sound of no power or gas
    LED numerical flux display



    Company: Ternary Anaesthesia & Respiration Equipment Co. Ltd.
  • Hand-squeezing ventilator
    The hand-squeezing ventilator sends certain ventilation by the hand-squeezing ventilating bail to product compulsively the air exchange in the airway and to improve the oxygen partial pressure so that the heart and lung can be resuscitated and the respiration can be managed.
    A. Adopt high quality silica gel or PVC skid-proof material to ensure good hand-squeezing feeling.
    B. Good elasticity, high-temperature-resistant, without transformative, without changing colour and be serviceable.
    C. With pressure safely valve to avoid to produce air pressure hurt.
    D. With multiform hand-squeezing bails for adults, children or infants.

    Specifications:
    BE-1000
    silica gel 1600ml first-aid resuscitator for adults
    BE-1000-1
    silica gel 1500ml first-aid resuscitator for adults
    BE-1000*
    silica gel 1600ml first-aid resuscitator for adults
    BE-1000*-1
    silica gel 1500ml forst-aid resuscitator for adults
    BE-1200*
    silica gel 550ml first-aid resuscitator for children
    BE-1300*
    silica 280ml first-aid resuscitator for infants
    BE-1400
    PVC 1600ml first-aid resuscitator for adults
    BE-1400-1
    PVC 1500ml first-aid resuscitator for children
    BE-1600*
    PVC 550ml first-aid resuscitator for children
    BE-1700*
    PVC 280ml first-aid resuscitator for infants


    Company: Ternary Anaesthesia & Respiration Equipment Co. Ltd.
Select to
Page 1 of 4 << Previous 1
Go to Page