Other Testing & Analyse Equipment trade,Other Testing & Analyse Equipment offer, Sell leads
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
Select to
Page 1 of 2
  • PW-960 Automatic Micro Plate Washer
    The 96-tube manifold allows the user to wash the full 96-well simultaneously, possible to achieve residual volumes as 1ul/well.

    PW-960 Automatic Microplate Washer was developed based on a great deal of experiments, adopting the advanced international design concept and mature technology. The microcomputer controls to complete the washing of various types of microplates used in enzyme-linked immunosorbent assay fast, efficiently and automatically. It is used widely for immunoassay in clinic lab, blood center, hospital, university, institute or other academic organizations.

    The Washer equipped with a 96-tube manifold allows the user to wash the full 96-well simultaneously, allowing a dramatic reduction of the total processing time, making the instrument particularly suited to high-throughput applications. Moreover, with the PW-960, it is possible to achieve residual volumes as low as 1μl per well.

    * High efficient: excellent washing result, high washing speed, fully automatic
    * Reliable: specially designed 96-tube manifold, particular jam prevention, detection and removing program, solve the problem of cross contamination and jam of hole
    * Easy work: Human-friendly program make the washing easy and pleasant

    Clean solution is well-distributed; waste is absorbed thoroughly. It ensures excellent washing result

    --Specially designed 96-tube Manifold with patent technology and second liquid leakage collection function make the solution distribution in 96-well very accurate (CV<1.5%).

    --Absorb the waste at two positions, residue in each well <1μL

    --Carry out the washing on the 96-well microplate with 96-tube mainfold by choosing any rows or whole plate to wash

    --There are two microplate holders. Two plates are soaked and washed in turn while one plate is being washed and another is being soaked. There is no waiting time when the plate is taken out or placed in. And there is no waiting time for soaking.

    No cross contamination

    --Pins for solution distributing and those for waste absorbing are separated. The pins for waste absorbing use real-time volume detecting technology to ensure the minimum contact.

    --Wash the bottom of the microplate intensively to ensure good washing result

    --Shake the microplate to eliminate the waste absorption efficiently

    Particular jam prevention, detection and removing technology

    --Specially designed manifold and pressure control technology to prevent the jam

    --The ultrafiltration of wash solution and automatic tubing flushing make it hard to form flocky or crystal precipitate

    --Specially designed jam detection and removing program make it easy to remove the jam

    --The tubing is cleaned and emptied automatically before the washer is powered off
    Tailor-made for various workload by only one washer

    --The washer can wash any row or several rows in the microplate even if they are not conterminous. There is no need to take apart the microplate

    --Two microplates are washed in turn without wasting time on waiting. It makes the washing very easy especially for heavy workload.
    Humanized design makes the operation every convenient and safe

    --Controlled by the microcomputer; English menu; large 3.5 inch LCD with backlight

    --Special rotation design for bottle cap makes the solution aspirating very convenient. Three kinds of wash solution is provided for selection and it is automatic to shift from one to the other

    --It senses the solution level automatically and alarms the trouble automatically. When the wash solution is not enough and the waste bottle is full it will alarm automatically

    --Intelligent maintenance: it will wash the tubing with distilled water automatically when the washer is powered on or powered off and periodically

    --Easy maintenance: it will collect the spilled solution from the bottom of microplate holder automatically; it will aspirate the leaked solution automatically

    --It will adjust the pressure inside the clean solution bottle automatically according to the number of microplate rows that will be washed

    --Specially designed pressure adjusting valve can do fine adjustment to the pressure of solution distributing and make sure the safety during the washing

    --Transparent and biological safety cover and close tubing system ensure the isolation of experiment materials from outside

    * Powerful functions

    --It can store 100 washing programs automatically, each program can store one microplate position independently

    --The position of the manifold can be adjusted to be compatible with various microplate, such as flat bottom microplate, circular bottom microplate, U shape bottom microplate, V shape bottom microplate, etc.

    --It can be used as a solution pipette device to coat the microplate. It can coat 1000 pieces of microplates per hour
    *Manifold: 96-tube, control of single needle injection fluid
    *Solution distributing precision between wells: CV≤1.5%
    *Rinse times: 0-99 adjustable
    *Rinse strip: any row of 1-8 or any column of 1-12, any well of whole strip
    *Wash mode: single microplate, double microplates or three microplates
    *Wash solution volume: 50-950μl per well adjustable, 50μl increment
    *Wash speed: 5 seconds /microplate / times, 2 microplates per minute, more than 100 pieces of microplate per hour
    *Soak time: 0-999 seconds adjustable
    *Shaking time of microplate: 0-999 seconds adjustable
    *Aspiration time: 1-9 seconds adjustable, 1 second interval
    *Residual volume: <1μl
    *Microplate washing position: A or B
    *Manifold position: 5 positions adjustable
    *4 kind of solution bottles: water, waste (4L), solution A, solution B (4L or 300ml)
    *Dispense precision: CV≤2.5%
    *Power Source: 220V·AC±30%, 50Hz±3Hz

    Company: Shanghai Xunda Medical Instrument Co., Ltd.
  • PW-812 Microplate Washer

    It is used widely for immunoassay in clinic lab, blood center, hospital, university, institute or other academic organizations.

    PW-812 Microplate Washer is controlled by a microcomputer to complete the washing of various types of microplates used in enzyme-linked immunosorbent assay fast, efficiently and automatically. It is used widely for immunoassay in clinic lab, blood center, hospital, university, institute or other academic organizations.

    High efficient Reliable Easy work
    Main features
    *  Keyboard editing, just pressing start button to automatically complete the washing process
    *  Large LCD can display all parameters of the procedure
    *  Absorb the waste at multi-position, residue in each well <1μL
    *  Two ways of washing for choosing: single strip and whole microplate
    *  The bottom washing function makes sure good washing result
    *  Having vibration mixing function and soaking function decrease the waste absorbing efficiently
    *  Having cleaning tubing function, and cleaning time is adjustable. It prevents the tubing from jam efficiently
    *  The pressure of wash solution can be fine adjusted so as to meet different washing demands
    *  The tubing is cleaned and emptied automatically before the washer is powered off
    *  There are five adjustable positions of Manifold to be compatible with various microplate, such as flat bottom microplate, circular bottom microplate, U shape bottom microplate, V shape bottom microplate, etc.
    *  Transparent and biological safety cover and close tubing system ensure the isolation of experiment materials from outside
    *  Two clean solutions for choice and three clean solution channels for users easy to switch
    *  With a liquid sensor, when the solution and waste bottle is full it will alarm automatically
    *  Any amount of Specimens can be carried out for cross-cleaning, without making up when there is less than a row of wells
    *  It can store 50 washing programs automatically, each program can store one microplate position independently
    *  Two pumps with low noise make the washing quiet

    Technological Specifications
    Ø Manifold: 8 or 12 channels (10 channels is optional)
    Ø Solution distributing precision between wells: CV≤2%
    Ø Rinse times: 0-9 adjustable (it can be increased to 99 times)
    Ø Rinse strip: 1-12 strip, adjustable
    Ø Wash solution volume: 50-3000μl per well, adjustable
    Ø Soak time: 0-240 seconds, adjustable (it can be increased to 3600 seconds)
    Ø Shaking time of microplate:0-240 seconds, adjustable (it can be increased to 3600 seconds)
    Ø Aspiration time: 0.1-9.9 seconds adjustable

    Ø Residual volume: <1μl/well

    Ø Wash solution: two types

    Ø Manifold position: 5 positions, adjustable

    Ø Dispense precision: CV≤2.5%

    Ø Power Source: 220V·AC±30%, 50Hz±3Hz


    Company: Shanghai Xunda Medical Instrument Co., Ltd.
  • MG48+ Peltier -based PCR

    Specification :

     
    Technology                                          Peltier -based
    Block Capacity                                   48wells ´0.2ml + 48wells ´0.5ml
    Block Temperature Range                     0°C ~ 99.9°C
    Max. Block Heating Rate                      3°C/sec
    Max.Block Cooling Rate                  2°C/sec
    Block Uniformity                                 ≤ ± 0.2°C
    Block Accuracy                                  ≤ ± 0.2°C
    Mode of Temperature Control        Sim-Tube & Block mode
    Ramping Rate Adjustable               0.1°C – 3°C
    LCD                                                    Large-size Blue LCD
    Max. No. of storable programs             >125
    Max. No. Of Cycle                            99
    Temp. Increment/Decrement           0.1~ 10°C
    Time Increment/Decrement                  1 ~ 60sec
    Auto Pause                                         Yes
    Auto Restart                                        Yes
    Hold at 4°C                                         Forever
    Running Time Display                         Yes  
    File Named                                         Yes
    Hot Cover Temperature                   105°C
    Height of Cover                                 Adjustable
    Hot Cover Auto Shut-Off                Yes
    Dimension( L´W´H)                         315mm´240mm´275mm
    Net Weight                                          8.8kg
    Wide Power Supply Range           170~270V 50/60Hz


    Company: ARI Medical Equipment Co.,Ltd
  • MG48+ Peltier -based PCR

    Specification :

     
    Technology                                          Peltier -based
    Block Capacity                                   48wells ´0.2ml + 48wells ´0.5ml
    Block Temperature Range                     0°C ~ 99.9°C
    Max. Block Heating Rate                      3°C/sec
    Max.Block Cooling Rate                  2°C/sec
    Block Uniformity                                 ≤ ± 0.2°C
    Block Accuracy                                  ≤ ± 0.2°C
    Mode of Temperature Control        Sim-Tube & Block mode
    Ramping Rate Adjustable               0.1°C – 3°C
    LCD                                                    Large-size Blue LCD
    Max. No. of storable programs             >125
    Max. No. Of Cycle                            99
    Temp. Increment/Decrement           0.1~ 10°C
    Time Increment/Decrement                  1 ~ 60sec
    Auto Pause                                         Yes
    Auto Restart                                        Yes
    Hold at 4°C                                         Forever
    Running Time Display                         Yes  
    File Named                                         Yes
    Hot Cover Temperature                   105°C
    Height of Cover                                 Adjustable
    Hot Cover Auto Shut-Off                Yes
    Dimension( L´W´H)                         315mm´240mm´275mm
    Net Weight                                          8.8kg
    Wide Power Supply Range           170~270V 50/60Hz


    Company: ARI Medical Equipment Co.,Ltd
  • Airborne Microbe Tester/Collector
    airborne microbe tester/collector can be used in the room or especial for isolator.

    Company: Hangzhou Geevo Technology Co., Ltd.
  • Airborne Microbe Tester/Collector
    airborne microbe tester/collector can be used in the room or especial for isolator.

    Company: Hangzhou Geevo Technology Co., Ltd.
  • Fast Microbial Test System
    fast microbial test system can save time for your company.

    Company: Hangzhou Geevo Technology Co., Ltd.
  • Fast Microbial Test System
    fast microbial test system can save time for your company.

    Company: Hangzhou Geevo Technology Co., Ltd.
  • Substitute Lemo odu Metal Connector
    : - push-pull self-locking security system
            - Welding, crimping and PCB access needle core (straight or corner type)
            
    - A variety of pin options to avoid a similar mixture between the plug connector
            
    -360 Degrees to provide full EMC shielding protection (anti-electromagnetic interference)
            
    - Multi-core core type 2-64
            - High density mounting, saving space
            - Pin system (G for the standard pin) connector for positioning


    Company: Dongguan Jingutong Electronic Technology co.,ltd
  • Substitute Lemo odu Metal Connector
    : - push-pull self-locking security system
            - Welding, crimping and PCB access needle core (straight or corner type)
            
    - A variety of pin options to avoid a similar mixture between the plug connector
            
    -360 Degrees to provide full EMC shielding protection (anti-electromagnetic interference)
            
    - Multi-core core type 2-64
            - High density mounting, saving space
            - Pin system (G for the standard pin) connector for positioning


    Company: Dongguan Jingutong Electronic Technology co.,ltd
Select to
Page 1 of 2 << Previous 1
Go to Page