XD 236 AutoBlot System is designed to operate the Western Blot kit automatically.
XD 236 AutoBlot System is designed to operate the Western Blot kit automatically. It is used widely for immunoassay in disease control center, clinic lab, hospital, blood center, institute, university, or other academic organizations.
XD 236 minimizes the possibility that the operator touches the potential infective blood sample to the utmost. The fully close system provides good protection for the operator. XD 236 minimizes the testing errors caused by the surroundings vary (temperature control) and different operators. Precise solution distributing and aspirating system ensures the testing result consistency and prevent the cross contamination between samples.
* Intended Application
The system is widely applied in the automatic test with Western Blot method. It is used to test HIV, HCV, HTLV, HP, etc. virus diseases, autoantibodies ENA (Extractable Nuclear Antigens) relative to in Rheumatic diseases, specific allergen and other diseases.
* Main Features
1. Free of operation during running
Temperature of shaking table: -25~30~37, adjustable
2. Friendly and convenient operating interface
38+2 preprograms can be stored, easy and convenient to operate
3. 36(30) lanes can be tested at the same time
4. Specially designed aspirating pins ensure no cross contamination
* New type aspirating pins with double solution levels and oblique mouth and negative pressure
* Automatic washing: it can wash each channel automatically according to the requirement
* Positioning function: It can adjust and position the moving parts of aspirating arm and distributing arm
* Distributing pump calibration: It can calibrate the distributing pump volume
5. Automatic peristaltic pump calibration
The volume of peristaltic pump can be calibrated automatically
6. Fully close tubing system
Provide good protection for the operator
7. Others
* Preprograms can be locked and unlocked
* Alarm function: can set to alarm when reagent or substrate is added, waste spills over or the test is over
* Help function: to help setup the name of distributing pump, item lock and unlock, search, etc.
Technological Specifications
* Lane capacity: 1-36 lanes or 1-30 lanes
* Programs ≥38+2 (preprogrammed)
* Distributing pump number: Standard 6 channels
* Distributing pump volume: 0000μL-3000μL
* Distributing volume calibration mode: Semi automatic, quantitative
* Incubation time: 0-24h/1min, circulation available
* Incubation time display mode: Hour minute second
* Shaking table speed: 3 levels, adjustable
* Communication: RS232 standard interface, Baud rate: 9600, Data bit length: 8 bit, Stop bit length: 1 bit, Parity bit: no
* Reagent bottle volume: 200mL×5
* Clean solution bottle volume: 1000mL×5
* Waste bottle volume: 2000mL×1, closed and negative pressure
* Display: Large LCD screen with backlight
* Power supply: AC 220V±22V, 50Hz ±1Hz
* Rated power<250VA
* Accuracy of reagents distribution: ±3.0% (when distribution volume in each channel is 2000μL)
* Precision of reagents distribution: CV≤5.0% (when distribution volume in each channel is 2000μL)
* Temperature of shaking table: Room temperature, 37, 30, 25
* Temperature accuracy: ±1.5
* Temperature precision: ≤0.2
* Cross contamination: When negative and positive samples are tested alternately, negative sample should have no positive strip