Product catalog - SEEUCO ELECTRONICS TECHNOLOGY CO.,LTD
Home » Products »

SEEUCO ELECTRONICS TECHNOLOGY CO.,LTD

Product

Product Group List

Select to
Page 1 of 1
  • Digital Electrocardiograph
    Features:
    Simultaneously acquisition of 12-lead ECG data, IEC Class I, type CF safety standard
    Selectable four modes of leads
    Function of ECG parameters measurement and distinguish point printing under automatic mode
    LCD display of operation menu, ECG waveform, AMP menu and parameter setting
    Powerful filter for AC, EMG and DFT interference
    AC and DC power supply, rechargeable built-in battery
    High solution and multiple print formats ensure best print quality of ECG waveforms
    Capability of the input & output for analog signal 
    Specifications:
      Input Circuit: Floating; protection against defibrillator effect
      Lead: Standard 12 leads, European leads
      Input Impedance: ??50M??
      Calibrating Voltage: 1mV±2%
      Digital Sampling: 12 bits (simultaneously acquisition of 12 leads ECG data)
      DFT Filter Automatic Adjustment
      Sensitivity: auto, 2.5, 5, 10, 20mm/mV
      Recording System: Thermal-array
      Paper Speed: 25, 50mm/s
      Paper Specification: 112mm/30m
      Safety: Standard IEC class I, Type CF
      Power Supply AC: 220V±10%, 50/60Hz±1Hz
      DC:14.4V-2000mAh rechargeable battery
      Depolarization Voltage: ±400mV

  • Anesthesia machine
    Specifications
    Suitable for Adult, pediatrics 
    Flow Meter O2, N2O 
    O2 Supply Speed 35L/min~75L/min 
    Respiratory Rate 1~99/min 
    I:E 1:4~4:1 
    Tidal Volume 50~1500ml 
    Ptr. Range -1.0kPa~1.0kPa 
    Max Safe Pressure ≤6kPa 
    MV Alarm Upper Limit: 18L/min; Lower Limit: 0~10L/min 
    Airway Pressure Alarm Upper Limit: 1~6kPa; Lower Limit: 0.5kPa 
    Patient Monitor
    Screen 12`` TFT large screen of high resolution 
    ECG 5-lead, gain 0.5X~2.0X adjustable or automatic, analysis of ST segment and abnormal of heart rate (anti-defibrillate, anti-HF electrotome) 
    Heart Rate 20~250bpm 
    RESP Impedance, range: 0~100bpm 
    SpO2 35%~100% 
    Pulse Rate 30~240bpm 
    NIBP SBP, DBP, MBP, 15~250mmHg interval of automatic measurement 1~250min adjustable 
    TEMP 28~43.2°C 
    Alarm Audio and visual alarm 
    Tendency record 96 hours  
     

  • Ventilator
    Tidal Volume Adjustment      50~1400ml
    Ventilation Capacity per Minute     ≥18L
    Oxygen Concentration     40%~90%
    Ventilator Conformance     ≤30mL/kpa
    Respiratory Rate     1~99/m
    I/E Ratio:     1/4.0~4.0/1
    Maximum Safe Pressure     ≤6.0kPa
    (Ptr)Range     -0.4~±1.0kPa
    Transfer Time from Controlled to Assistant Respiration     6s
    Air Flow Adjustment     1~12times /m
    PEEP     0~1.0kPa
    Sigh Volume:     150% of tidal volume
    Oxygen Consumption:≤1.5mPa change in pressure after 1-hour operation of oxygen cylinder of 12250kPa/40L.



  • Fetal Doppler
    It is very advanced obstetrical fetal doppler, which used to detect the FHR (Fetal heart rate), can meet routine examination requirements of obstetricians. The device is consists in the following procedure:

    Ultrasonic signal emit

    Analog signals process

    It has a 2 sockets for audio output can be connected with headphone or audio recorder

    It use standard


  • X-ray unit
    Specifications 
    Power Output 3.5KW 
    Frequency 40KHz 
    X-Ray Tube Fixed anode 
    Focus 1.5 
    Tube Voltage 40~110KV (interval 1KV) 
    Tube Current 40~49KV 63mA 1~125 mAs 
    50~59KV 56mA 1~110 mAs 
    60~69KV 45mA 1~90 mAs 
    70~79KV 40mA 1~80 mAs 
    80~89KV 36mA 1~71 mAs 
    90~99KV 32mA 1~63 mAs 
    100~110KV 20mA 1~40 mAs 
    mAs 1.0~125 mAs (45 steps) 
    Power Supply 220V±10% 50Hz inner-resistance≤1.0?? 
    Operation Method Wire /Wireless control 

  • Multi-parameter Monitor
    Features
    12.1"High brightnees TFT LCD display
    Portable ,streamline handle design
    Big figure display
    ECG Waveforms of 7-lead displayed in one screen
    96-hour tabular and graphic trends & date storage
    Compatible and self identify 3-lead and 5-lead ECG cable
    NIBP dual Over Pressure Protection
    Isolated floating,anti defibrillation protected and anti high-frequency interference 
    Standard parameter & configuration
    3/5 lead ECG,RESP,SpO2,NIMP,TEMP,PR,Network 
    Optional parameter & configuration
    2-IBP,Recorder,12 lead ECG,ETCO2  
     

Select to
Page 1 of 1 << Previous 1 Next>>