  • Dental x-ray unit

    Dental x-ray unit

    DC (high frequency) Dental X-ray unit

    Technical data:

    1.the range of tube voltage can be adjust55KVp55KVp60KVp65KVp70KVp

    2. tube current7mA3mA(RVG mode)

    3. the range of exposure time can be adjust0.05S2.00S

    4.focus skin distance220mm .

    5.power supply220V,5A,50/60Hz or  110V,10A, 50/60Hz Either will be fine.),

    6.frequency conversion200kHz.

    7.duty cycle:1/30

    8. Scattered radiation:0.14mGy/h

    9.focal spot size:0.8(IEC336/1993)

    10.circular radiation field diameter:<60mm tube head weight:4.5kg

    12.setting quomodowall support,floor support or mobile

  • Dental Instrument (x-ray Unit)
    Dental Instrument

    X-Ray Unit

    CHARACTERISTIC
    1.The microprocessor-controlled timer brings high-tech x ray imaging at your fingertips.
    2.The control panel allows an accurate and fast exposure time selection while protecting the head during x-ray examintions.
    3.Fitted with 70KV 8mA tube with preheating grid.The machine has been specially designed for intraoral dental  diagnosis applications.
    4.Compiles with local and international regulations on ionizing radiation protection for maximum safety
    5.The soft positioner arm ensures naturally smooth andwell-balanced movements.it is easy installed at the desired height and length..
    6.Its ergonomics and design have been studied to meet the requirement of the most semanding practices in matters of floor space optimization


    TECHNICAL DATA
    1. Classification :Electromedical , Class1,tpyeB
    2. supply vollage:220v 50Hz
    3. X ray tube:70kv 8mA
    4. Total fiteration: 2.5mmAL
    5. Exposure time: 0.2 to 4 second
    6. Total weight: 35Kg
  • Dental X-Ray Machine

    Dental X-Ray Machine

    DC (high frequency)  Dental X-ray unit

    Technical data:

    1.the range of tube voltage can be adjust55KVp55KVp60KVp65KVp70KVp

    2. tube current7mA3mA(RVG mode)

    3. the range of exposure time can be adjust0.05S2.00S

    4.focus skin distance220mm .

    5.power supply220V,5A,50/60Hz or 110V,10A, 50/60Hz Either will be fine.),

    6.frequency conversion200kHz.

    7.duty cycle:1/30

    8. Scattered radiation:0.14mGy/h

    9.focal spot size:0.8(IEC336/1993)

    10.circular radiation field diameter:<60mm

    tube head weight:4.5kg