Medical Analyzer direct from China - Nanjing Everich Medicare Import & Export Co.,Ltd
Home» products»Medical Analyzer

Nanjing Everich Medicare Import & Export Co.,Ltd

Select to
Page 1 of 2
  • Automatic Random Access Chemistry Analyzer,KY-190

    KY-190 Technical Specifications
    Colorimetry Method: reaction cup continuously test directlydiscrete
    Analysis Method: end-pointkinetictwo-pointdual-wavelengthdual -reagentmulti-standard and so on, all test method are open for domestic and imported reagent.
    Parameters: on-line maximum 50 testing items at the same time
    Throughput: 260 samples per hour
    Sample device: 30 sample positions, include standardQC and emergency position; The primary tube or blood serum cup is adoptable (it is possible to extend 60 sample positions)
    Sample Volume: 2-50 ul
    Reagent position: 30 reagent position, 40ml reagent bottle, the system detect the remained volume of the reagent bottle.
    Reagent volume:10-400ul, 1ul step
    Liquid level detect: detect the liquid level automatically, crashworthy system
    Reaction time:10 Minutes
    Reaction temperature: 37±0.1
    Cuvette: reaction cup with 90 units of subminiature special type material
    Cleaning system: Detect cup with 8 sect automatic washing, water consumption 3-5L/hour, the cuvette cup dry automatically
    Calibration: Linear / Nonlinear multi-point calibration
    Sample dilute/re-test: dilute and re-test the sample automatically when the result is out of the linearity range or the sample is short
    Light Source: Halogen-tungsten lamp
    Wavelength range: 300-700nm
    Wavelength: 8 wavelength, Precision ±2nm
    Test method: single aperture test
    Test range: 0.0000-4.0000 OD
    Emergency function: insert emergency treatment sample randomly.
    Quality Control: Various quality control management function, insert the QC randomly; Save, display and print QC chart; define the different QC material in advance; one test item attached with three QC materials.
    Software: Windows XP and Window 2000. Convenient operation
    Data Processing: Edit and save more than 300 testing parameters, memory up to 200,000 patients data
    Print: Multi-format printouts
    Power Supply: 220V  50Hz  1KV
    Dimension: 450mm × 600mm × 460mm (W × D × H)
    Weight: 60kg

  • Automatic Hematology Analyzer, TEK-II MINI
    Automatic Hematology Analyzer, TEK-II MINI, CE Certified.

    Specification: 21 parameters full automatic 3-diff

    Performance and Parameters:

    1.Principle: Electrical impedanceTest HGB without Cyanide.

    2.Structure: Cosmically integrate micro technology,automatically work under control by relate programs.

    3.Test Item:19 parameters + 3 histograms
           WBC  RBC  HGB  HCT  MCV  MCH  MCHC  PLT  RDW-CV  RDW-SD
           MPV  PCT  PDW  LY%  LY#   MO%  MO#   GR%  GR#
           WBC histogram   RBC histogram  PLT histogram

    4.Operation: Full automatic

    5.Throughput: More than 60 samples/h

    6.Sample volume: 15ul venous blood or capillary

    7.Reagent: Made in China

    8.Linearity range:  WBC  0.0-99.9×109L    RBC  0.0-9.99×1012L
                                            HGB  0.0-300g/L   PLT  0.0-999×109L

    9.  Carry over: ≤1.0%

    10. Feature: Patent block-clearing technology.Lower rate of block.Simple and convenient operation.Lower cost of working.

    11.Quality Conrol functions: Multiform

    12.Data storage:1 thousand test results with 3 histogram.

    13.Interface:Chinese and English

    14.Display:High resolution LCD

    15.Print: Built-in thermal printer, optional external dot printer.

    16.QC substance: National register calibration substance and QC substance111
  • Urine Analyzer,KH-100 B09.01005

    KH-100 Urine Analyzer

     Performance:
    1.Super LCD monitor
    2.Adopt luminescence source with high brightness to minimize
       interference of the environmental light.
    3.The color and limpidness can be input
    4.Date and patient number can be input.
    5.Single test and continuous test are available
    6.The data can be saved automatically.

     Technical feature:
    1.Wave length: 510-650nm
    2.Throughput: 120 test/hr
    3.Storage: 1000 patient data
    4.Display: 240x64 LCD monitor
    5.Print: 57mm thermal printer
    6.InterfaceStandard RS232 serial interface
    7.Calibration: fully automatic calibration
    8.Condition: temperature: 15-35, humidity:10-85%
    9.Power supply: 220VAC±10%  50~60Hz  100W

     Test items:
    1.PH, Nitrite, Protein
    2.Glucose, occult blood, bilirubin
    3.Urobilinogen, ketone
    4.Specific gravity,Leukocytes
    5.Ascorbic Acid

  • Semi-automatic Biochemistry Analyzer

    Semi-automatic Biochemistry Analyzer

    Performance:
    1. Reasonable software, programmable biochemical test menu, 200 test programmes can be
       saved.
    2. 1000 patients test data can be saved.
    3. Clock CMOS chip inserted.
    4. Hermetic solid-state optical system, low contamination of dust and dampness,long life
       time of hard membrane filters.
    5. Back spectro photometry, 8 hard membrane filter, separate signal process circuit for
       each wavelength, filters select completed electronically,no mechanical movement.
    6. Titanium alloy flow cell with small capacity and minimize cross-contamination.
    7. Back-light LCD monitor and display character and curve simultaneously
    8. Self-test program, test error<1%, CV<3%

    Environment
    Temperature :0-40
    Humidity: 5-80%

    Technical feature:
    1.Analysis method: kinetics, end point, two point, etc.
    2.Power supply: 20w/12V halogen light, life time: 2000hr
    3.Optical system: 340-800nm, 8 hard membrane filter: 340, 380, 405, 492, 510, 546, 578,
      630nm(wavelength). Accuracy±2nm
    4.Abs range: -2.5002.5Abs, resolution:0.001Abs.
    5.Flow cell: titanium quartz alloy, 33uL; optical path: 10mm.
    6.Temperature: PELTIER elements, 25,30,37 0.1±
    7.Precision: error<1%, drift<5mAbs/hr
    8.200 test programmes can be saved
    9. 58mm thermal printer, no noise, high speed, easy maintenance.
    10.Keyboard: 24 keys touch keyboard
    11.Power supply: 220V±15%, 50Hz, 70VA
    12.Interface: standard RS232 serial interface
    13.Dimensions : 460(L)x380(W)x200(H)mm
    14.Weight: 13Kg(net), 15Kg(gross)

  • Automatic Random Access Chemistry Analyzer,KY-290
    Colorimetry Method: reaction cup continuously test directlydiscrete
    Analysis Method: end-pointkinetictwo-pointdual-wavelengthdual -reagentmulti-standard and so on, all test method are open for domestic and imported reagent.
    Parameters: on-line maximum 50 testing items at the same time
    Throughput: 300 samples per hour
    Sample device: 30 sample positions, include standardQC and emergency position; The primary tube or blood serum cup is adoptable (it is possible to extend 60 sample positions)
    Sample Volume:2-50 ul 0.1ul step
    Reagent position: 50 refrigerated reagent position, 50ml reagent bottle, the system detect the remained volume of the reagent bottle automatically.
    Reagent volume:10-400ul, 1ul step.
    Liquid level detect: detect the liquid level automatically, crashworthy system
    Reaction time:10 Minute
    Reaction temperature: 37±0.1
    Cuvette: reaction cup with 90 units of subminiature special type material
    Cleaning system: Detect cup with 8 sect automatic washing, water consumption 3-5L/hour, the cuvette cup dry automatically
    Calibration: Linear / Nonlinear multi-point calibration
    Sample dilute/re-test: dilute and re-test the sample automatically when the result is out of the linearity range or the sample is short
    Light Source: Halogen-tungsten lamp
    Wavelength range: 300-700nm
    Wavelength: 8 wavelength, Precision ±2nm
    Test method: single aperture detect
    Test range: 0.0000-4.0000 OD
    Emergency function: insert emergency treatment sample randomly.
    Stirring function: Furnished
    Alarm function: alarm when there is a lack of reagent or the waste liquid overflow
    Quality Control: Various quality control management function, insert the QC randomly; Save, display and print QC chart; define the different QC material in advance; one test item attached with three QC materials.
    Software: Windows XP and Window 2000. Convenient operation
    Data Processing: edit and save more than 300 testing parameters, memory up to 200,000 patients data
    Print: Multi-format printouts
    Power Supply: 220V  50Hz  1KV
    Dimension: 950mm × 700mm × 1200mm (W × D × H)
    Weight:175kg
  • Automatic Electrolyte Analyzer

    Automatic electrolyte Analyzer
     The most advanced ionic selective electrode(ISE); Perform multiparameters as K+, Na+, Cl-,
    Ca++,PH etc. Adapt to all hospitals with different sizes

    Performance:
    1. More advanced ionic selective electrode (ISE),
       longer shelf-life
    2. Automatic time calibration, 24 hours power on, fitting for emergency treatment.
    3. reagent supplies with lower cost
    4. rapid and accurate test
    5. free maintenance

    Technical character:
    1.Assay method:  ionic selective electrode
    2.Assay time: 25 seconds(measure time) less than 48 seconds(the whole course,including
       sucking samples,reaction,washing and print)
    3.Sample volum: 120uL/70uL
    4.sample type: blood serum, blood plasm, whole blood, cerebrospinal fluit, diluted urine
    5.Data storage:  300 samples, Q.C. data for one month
    6. Display:240X64 back-illuminated liquid crysatl
    7. Printer:thermal printer,58mm paper width
    8. ISE life:more than 10 months
    9.Temperature/humidity0-40 /≤85%
    10.Power supply: AC 220V±20%  50Hz  30W
    11.Dimensions : 370(L)x280(W)x225(H)mm
    12.Weight: 7.5Kg(net), 8.5Kg(gross)


     

Select to
Page 1 of 2 << Previous 1
Go to Page