  • KHB-202 Coagulometer

    KHB202 Coagulometer

    KHB202 Coagulometer adopts the world approved coagulation test method; the CPU adopts ARM
    technology to measure the motion of the magnetic ball to work out the coagulation time.
    It can perform multiparameters simultaneously with better accuracy, precision and repitition.

    Performance
    1. Double magnetic route, stable performance , not liable to interference.
    2. Dot-matrix LCD monitor
    3. 100 assay parameters and 1000 test results can be saved
    4. touch keyboard
    5. thermal printer
    6. Reagent-open, less consumption  ( ≤200uL)
    7. Clock CMOS chip inserted
    8. Standard 232 serial interface
    9.Power supply: 220V±15%, 50Hz, 80VA
    10.Dimensions : 420(L)x300(W)x170(H)mm
    11. Weight: 5Kg(net), 7Kg(gross)

    Technical character
    1. Test method: magnetic ball method
    2. sample consumption: ≤200uL
    3. reagent consumption: 50uL~200uL
    4. Temperature: 37±0.5
    5. adding sample:  by a timing linkage
    6. precision: ±10%; CV ≤10%
    7. speed:  ≤300s(depend on setting)
    8. channel: 4/2/1
    9. sample warming up position: 16/8/8
    10. reagent warming up position: 6/6/6

    Test itmes
    Main test:
    PT
    APTT
    TT
    FIB
    Others:
    Hep
    ProC
    ProS
    Coagulation factor II,V,VII,VIII,IX,X,XI,XII
    AT-III
    AT
    RepT
    RVVT
    RVVCT
    RVVRT
    LA

  • Automatic Hematology Analyzer, TEK-II

    Automatic Hematology Analyzer, TEK-II

    Specification: 21 parameters full automatic 3-diff

    Performance and Parameters:

    1.        Principle: Electrical impedanceTest HGB without Cyanide.

    2.        Structure: Analyzer combined with computer. No need for external PC. Standard Keyboard.

    3.        Test Item:18 parameters + 3 histograms         

    4.        Operation: Full automatic

                   WBC  RBC  HGB  HCT  MCV  MCH  MCHC  PLT  RDW-CV  RDW-SD
                    MPV  PCT  PDW  LY%  LY#   MO%  MO#   GR%  GR#
                    WBC histogram   RBC histogram  PLT histogram
    5.        Throughput: More than 60 samples/h

    6.        Sample volume:15ul venous blood or capillary

    7.        Reagent: Made in China

    8.        Linearity range: WBC  0.0-99.9×109L    RBC  0.0-9.99×1012L
                     HGB  0.0-300g/L   PLT  0.0-999×109L

    9.  Carry over: ≤1.0%

    10. Feature: Patent block-clearing technology.Lower rate of block.Simple and convenient operation.Lower cost of working.

    11.Quality Conrol functions: Multiform

    12.Data storage: 2 million test results with 3 histogram.

    13.Interface: Chinese and English

    14.Display: 12.1Color LCD

    15.Print: Built-in thermal printer,optional external dot printer.

    16.Maintenance: Automatically system diagnosis.Automatically setup maintain program.

    17.Management: Inspector login with ID number and password.

    18.Shut down: Automatically shut down.Clearing by itself.cutting off power suplly.Do not need maual work.

    19.QC substance: National register calibration substance and QC substance.

    CE Certified