Multi-parameter Patient Monitor direct from China - Nanjing Everich Medicare Import & Export Co.,Ltd
Home» products»Multi-parameter Patient Monitor

Nanjing Everich Medicare Import & Export Co.,Ltd

Select to
Page 1 of 2
  • Portable Patient Monitor,PM-400A

    Flexible (0-90degree)12.1 inch high resolution(1024 * 768) colorful TFT LCD
     Simultaneous display of 7 lead ECG in one frame
     Analysis of real times ST segment and arrhythmia
     Standard parameter of 7 lead ECG , NIBP , RESP , digital SPO2 , TEM and PR with optional configuration IBP , ECTO2,built in printer , drug does calculation and OXYCRG
     Maximum 120 hour graphic and tabular trend with data storage
     Networking capacity of maximum 66 beds and compatibility with HIS
     Digital SPO2 enables effective examination in case of active patient and low infusion as well interference caused by electric knife
     Compact and portable design allows uninterrupted with its built in rechargeable battery

    Standard Accessory
     

    5 lead ECG cable 1pc
    NIBP tube and cuff 1pc
    Temp probe 1pc
    Digital SPO2 probe 1pc
    ECG electrodes 10pcs
    Built in rechargeable battery 1pc
    Power cable 1pc
    Grounding cable 1pc
    Fuse 2pcs
     
     

  • Multi-Parameter Monitor,Palm type A07.01008

    Features:

    Compact,light weight,Easy for carrying and handling
    Touch Screen, LCD Display
    36-hours trend data
    Automatic Power-off
    Build-in Ni/MH rechargeable battery
    Low battery power indicator
    Technical Data:

    ECG
    Input: 3-leads ECG Cable,standard AAMI Cable connector
    Lead selection: I, II, III
    Gain Selection:   x1,  x2, x4, x8
    Sweep Speed:  12.5mm/s ,  25mm/s, 50mm/s
    Bandwidth:   0.5Hz-40Hz(for monitor or opertion)    0.05Hz-100Hz(For diagnosis)
    Calibration signal:   1mV
    Protection: Against electrosurgical interference and defibrillation.
        2.   HEART RATE

    Measure Range:  20bpm-250bpm
    Accuracy:    ±1bpm
    Resolution   1BPM
    Alarm Mode: Audible and visual alarm
        3.  NIBP

    Method:  Oscillometric
    Mode: Manual,Auto, STAT
    Measuring interval in Auto mode:  1,2,3,5,10,15,20,30,60(min)
    Measuring period in STAT mode:  5min
    Measuring type: SYS, DIA, MEAN
    Resolution:   1mmHg
    Over-pressure protection:     Yes
        4.  Oxygen Saturation (SpO2)

    Range:   35%-100%
    Accuracy:    ±2% (70%-100%), ±3% (40%-69%),
    Pulse Rate: Range:   0bpm-250bpm
    Accuracy: ±1bpm
      5.  Temperature

      Measuring Range: 0-50
      Resolution:  0.1
      Accuracy:  ±0.1


    Operation Environment: 

    Temperature:   0-45

     Humidity:  30-85(non-condensing)

    Power option:    Ni/MH Rechargeable battery

    AC: 100V-240V, 50Hz-60Hz, 10VA

    Dimension:    150mm x 114mm x 45mm

    Net Weight:   600G

    OEM acceptable        

  • Patient Monitor A07.01003
    1) Standard configuration: ECG, RESP, NIBP, SpO2, TEMP, HR, built-in battery (for using over 2 hours) ;
    2) Optional configuration: Printer, ETCO2, IBP, dual TEMP;
    3) Highly integrated module technology, more stability and reliability as well as lowest consumption;
    4) 12.1" TFT color LCD;
    5) Nine wave-channel display at most;
    6) Two selective user Interface: 9 channel waves UI, 4 channels waves, UI 7 leads ECG and screen displaying;
    7) Available to connect with the central monitor system.
  • Patient Monitor A07.01002
    1) Standard configuration: ECG, RESP, NIBP, SpO2, TEMP, HR, built-in battery (for using over 2 hours) ;
    2) Optional configuration: Printer, dual TEMP;
    3) Highly integrated module technology, more stability and reliability as well as lowest consumption;
    4) 12.1" TFT color LCD;
    5) Nine wave-channel display at most;
    6) Two selective user Interface: 9 channel waves UI, 4 channels waves, UI 7 leads ECG and screen displaying;
    7) Available to connect with the central monitor system.
  • Patient Monitor A07.01001

    1) Standard configuration: ECG, RESP, NIBP, SpO2, TEMP, HR, built-in battery (for using over 2 hours) ;
    2) Optional configuration: Printer, dual TEMP;
    3) Highly integrated module technology, more stability and reliability as well as lowest consumption;
    4) 12.1" TFT color LCD;
    5) Nine wave-channel display at most;
    6) Two selective user Interface: 9 channel waves UI, 4 channels waves, UI 7 leads ECG and screen displaying;
    7) Available to connect with the central monitor system.

  • Table Top Type NIBP&SPO2 Patient Monitor
    Table Top Type NIBPSPO2 Patient Monitor
    Parameters   Three parametersNIBP, SPO2, Pulse Rate.
    Waveforms:        No waveform.
    Features
    1.Compact, light, easy for carrying and handling.
    2.Large bright LED display of measurement, easy to read.
    3.Unique character and icon display of information, easy for setting and watching.
    4.Storage and review of NIBP and SpO2 data up to 800 groups.
    5.Buildin rechargeable LI-battery for 10 working hours.
    6.Low battery power indicator.
    7.Automatic power-off.
    8.Audio and visual alarm.
    9. External printer available.
    H.S.Code: 90181930
    Net Weight: 1.1kg  
    Gross Weight: 2.2kg
    Volume and Charge Weight: 3.5kg
    Package Size: 360x330x175mm
    Standard Packing List
    1. NIBPSPO2 Patient Monitor main unit 1pc
    2. Adult finger SpO2 sensor 1pc
    3. Adult NIBP cuff 1pc
    4. Child NIBP cuff 1pc
    5. NIBP extension tube 1pc
    6. AC power adaptor 1pc
    Selectable Accessory
    Child finger/toe SpO2 sensor
    Printer
    Technical specification Specifications
    1. General Specifications:
    Size: 205mm×200mm×95mm
    Weight: 1 kg
    Display Specification
    Parameter Display: 7-segment LEDs
    Information Display: Fixed characters and icons lighted by single-color LEDs
    Power Supply Indicator: Dual-color LED
    2. Power Supply
    AC Power Adaptor
    Input: 100-240VAC, 50/60Hz
    Output: DC 9V,800mA
    Battery
    Lithium-ion rechargeable 5AHr 7.2V battery 
    Operating time: 10 hours with full battery capacity.
    (Condition: 25, NIBP working period is 10 minutes.)
    Recharge Time: 20 hours.
    3. Environment
    Temperature
    Working: 0 ~ 45 (°C)
    Transport and Storage: -25 ~ 85 (°C)
    Humidity
    Working: 30% - 85 %
    Transport and Storage: 30% - 95 % (no condensation)
    4. Monitoring Parameter
    NIBP
    Method: Oscillometric
    Mode: Manual, Auto, STAT
    Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 60 (min)
    Measuring Period in STAT Mode: 5 min
    Cuff Pressure Range: 0 - 300 (mmHg)
    Pulse Rate Range: 30 - 250 (bpm)
    Measurement Rage: Adult 30-255mmHg, Pediactri 30-160mmHg
    Over-pressure Protection: Adult 300mmHg, Pediactri 220mmHg
    Pressure Resolution: 1mmHg
    The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using end artery blood pressure measurement device.
    SpO2
    SpO2%
    Measuring Range:   35 - 99%
    Resolution: 1 %
    Accuracy:     ±2 %(70% - 99%), unspecified (0% - 69%)
    Pulse Rate
    Measuring and Alarm Range: 0~250bpm
    Resolution: 1bpm
    Accuracy: ±1bpm
    Storage and Review
    Storage Method: Store NIBP and SPO2 data each time after one NIBP measurement. Maximum Store Data of 800 groups.
    5. Printer (optional)
    Type: Thermal microprinter
    Record Width:     57 mm
    Recording Types: Real-time printing and review data printing
    AC Power Adaptor
    Input: 100-240V,50/60Hz
    Output: DC 5V, 3A
Select to
Page 1 of 2 << Previous 1
Go to Page