Suction Machine direct from China - Nanjing Everich Medicare Import & Export Co.,Ltd
Home» products»Suction Machine

Nanjing Everich Medicare Import & Export Co.,Ltd

Select to
Page 1 of 2
  • Electric Suction Apparatus
    Electric Suction Apparatus,a light,but powerful and easy tocarry unit,is especially available for draining and removing blood,pusor secretion from the pleural cavity in emergency cases.
    Specifications

       1. Pump:rotary vane type
       2. Max Vacuum:≥0.09MPa(680mmHg)
       3. Free airflow:≥20L/minin pump exit:≥30L/min
       4. Vacuum adjustable range:0.020.09MPa
       5. Liquid storage bottle:1000ml×2
       6. Power supply:AC220V±10%,50Hz
       7. Input:280VA
       8. Dimemsion:480mm×340mm×370mm
       9. G.W.:17kg
  • Electric Suction Apparatus
    Electric Suction Apparatus model YB·DX23D-1A,a high vacuum,high flow medical suction unit with a trolley-style absorbs varied mucus rapidly from body cavity or wound to satisfy most demands in operation rooms,wards and so on.
    .Features

       1. A oil-impregnated vanes pump,Large-bore bottle,transparent hoses and unique connections,unit case made of engineering plastics,external appearance novel,structure reasonable.
       2. Two-stage overflow protection devices prevent liquid entering pump effectively; Air filter equipped reduces bacterium in absorbed liquid to environamental pollution.
       3. compact,light weight,put-and-pull smoothly,convenient to move.

    .Specifications

       1. Max.Vacuum≥0.09MPa(680mmHg)
       2. Flowrate≥30L/Min
       3. Storage bottles2500ml×2
       4. Vacuum Adjustable Range:0.02MpaMax.vacuum
       5. Noise≤60dB(A)
       6. Power supply220V±10%,50Hz
       7. Input280VA
       8. Dimemsion460mm×390mm×510mm
       9. G.W.19.5kg
  • Low-Pressure Suction Apparatus
    Low-Pressure Suction Apparatus model DY-1A is intended for continuous suction after operation for intestines,stomach and thoracic and celiac cavity or in the Dept.of surgery,internal medicine and pediatrics.
    .Feacture

       1. Powered by electromagnetic pump,no positive pressure producing.
       2. Stopping and alarming automatically when the storage bottle is full of liquid.
       3. Air filter equipped reduces bacterium in absorbed liquid to environmental pollution.
       4. Compact,lightweight,plastic liquid bottle and unit case,easy to carrying.

    .Specifications

       1. Max.vacuum≥1820kpa
       2. Adjustable vacuum:2kPaMax.vacuum
       3. Flowrate:≥5L/min
       4. Noise≤55dB(A)
       5. Storage bottle:1000mL
       6. Power supply220V±10%,50Hz
       7. Input power30VA
       8. G.W.4.8kg
       9. Dimension500mm×260mm×350mm


  • Model NKJX-2 Endoscope Suction Unit
    Model NKJX-2 Endoscope Suction Unit is specially designed for using suction of endoscope chamber. It can be used to suck out mucus from stomach and intestines,and many kinds of residual liquid.When endoscope is used in inspecting the stomach and intesties,colon,bronchus,etc,so that it can enhance the resolving power of imaging and the observing clarity.provided the means of therapy and treatment,to achieve the goal of examine accuracy in various diseases.
    .Feature

       1. The suction velocity of this product is fast,the control of negative pressure is suitable and difficult to be absorbed by the innewall,thus avoid injuring the soft tissures.
       2. Two steps of suction are available separately used for stomach and intestine examination.
       3. The suction can also be steplessly controlled between the maximum and the minimum.
       4. This unit installs the filter to filtrate fog and precaution set to prevent liquid sucking into pump,and the safety set to avoid emerging positive pressure.
       5. The construction of this unit is reasonable,operation is easy,usages is safe,reliable,and possess low noise,save electric consume,remove convenient,save labour.

    . Specifications

       1. Max Vacuum:≥0.085MPa(640mmHg)
       2. Free airflow:≥24L/min
       3. Liquid storage bottle:1500ml ×2
       4. Value of negative pressure at stomach and intestines(for reference only)
          Stomach0.04MPa(300mmHg)
          Intestines0.08MPa(600mmHg)
       5. Noise level:≤60dB(A)
       6. Input:250VA
       7. Power supply:AC220V±10%,50Hz
       8. Dimemsion:380mm×370mm×540mm
       9. G.W.:20kg


  • Electirc Suction Apparatus

    ElectircSuction Apparatus Model YB-DX23B,a powerful secretion suction unit,isdesigned especially to meet high demands in hospitals and doctorpractice.
    .Features

       1. Efficient single rotor vacuum pump with oil impregnated vanes is capable of a high flowrate and durability.
       2. Pump runs practically with minimum noise.
       3. Suction bottle provides automatic overflow cut off system.preventing liquid from flowing back into the pump.
       4. The unit has an ideal volume of suction capacity,Vacuum pressure can be controlled optionally from 0.02 to 0.09 Mpa(150680mmHg).
       5. Due to the reasonable arrangement and appropriate height,it allows the operator to observe and examine from all directions.
       6. The unit is simple to operate and easy to carry.
       7. It is ideal for most in hospital applications.

    . Specifications

       1. Max Vacuum:≥0.09MPa(680mmHg)
       2. Free airflow:≥30L/min
       3. Liquid storage bottle:2500ml×2
       4. Power supply:AC220V±10%,50Hz
       5. Input:280VA
       6. Dimemsion:420mm×420mm×870mm
       7. G.W.:29kg


  • Endoscope Suction Machine (NKJX-2)
    Chief Introduction:

    Model NKJX-2 endoscope suction unit is specially designed for usingsuction of endoscope chamber. It can be used to suck out musus formstomach and intestines, and many kinds of residual liquid. Whenendoscope is used in inspecting the stomach and intestines, colonbronchus etc, so thay it can enhance the resloving power of imaging andthe observing clarity. Provided the means of therapy and treatment, toachieve the goal of examine accuracy in various diseases.

    Specifications:
    1\ Max Vacuum: ≥ 0.085MPa(640mmHg)
    2\ Value of negative pressure at stomach and intestines
    (for reference only): Stomach: 0.04MPa Intestines: 0.08MPa
    3\ Flow rate: ≥ 24L/min
    4\ Noise: ≤ 60dB(A)
    5\ Storage bottles: 1500ml*2
    6\ Power supply: AC220v± 10%\50HZ
    7\ Input: 110VA
    8\ G. W.: 14KGg N. W.: 11.5Kg
    9\ Dimension: 38*37*54CM
Select to
Page 1 of 2 << Previous 1
Go to Page