USE
Roentgenoscopy; Digestive track spot film photograpy; General photograpy; Filter-ray device photograpy
MAIN TECHNICAL PARAMETER
1. Single bed and single tube
2. Rotary anode X-ray tube unit and tangential pipe sleeve.
3. monophase full-wave rectification high-voltage generator.
4. Supply voltage V, roentgenoscopy and photograpy kV, infinitely variable control and electric mechanism.
5. Equipped with capacity protective circuit,and kV mAs sectional and graduated interlock protection.
6. Equipped with the manostat for filament of X-ray tube and equipped with space-charge compensator.
7. Adopt the digital circuit timer, grade according to R10 priority coefficient and can control time exactly.
8. Equipped with the digital circuit device for roentgenoscopy time accumulation.
9. Examining bed is of electric back rotation, with external balance structure and with vibrating filter-ray device.
10. The spot film device of luminescent screen can hold the film jacket of various sizes and solenoid valve locking.
11. Upright post is of top and bottom track. It moves lightly.
ITEM CONTENT INDEX
Fluoroscopy voltage 40100kV be adjustable continuously
current 0.55mA
Photograpy voltage 40100kVbe adjustable continuously 40125kV be adjustable
current small focus 50mA and big focus 30 100 150 200mA,five grades
spot film 150mA( fixed )
time 0.046.3s 23 grades together
High-voltage generator capacity 20kVA( instantaneous )
Max dc output voltage 100KV 125KV
Max dc output current 200mA
X_ray tube model XD51-20.40/100 XD51-20.40/125
focus 1×1mm 2×2mm
Examining bed rotary angle +90° 0 ° -10°
movable range of spot film device(stomach and intestines photograpy) lengthwise 580mm
transverse ± 90mm
pressure down 300mm
specification of spot film 127×177.8mm(5×7)
203.2×254mm(8×10)
254×304.8mm(10×12)
279.4×355.6mm(11×14)
filter-ray grid characteristic N28
converging distance fo 100cm
grid proportion r8
distance between bed face and film 70mm
collimator manual single blade
Upright adjusting scope(distance between top and bottom track) 2800-3400mm
move lengtwise (along top and bottom track) 3100mm
move transverse(along horizontal arm ) 800mm( from bulb focus to he centre of upright post)
move up and down (along upright post) 3251830mm( from bulb focus to groud)
Power supply Voltage 380V/220V
Frequency 50Hz ± 0.5Hz
Inner resistance 380V:0.9 Ω ,220V:0.3 Ω
UNIT CONFIGURATION
Control desk high-voltage generator unit
high voltage cable X-ray tube assembly
Radiographic table-pillar of X-ray source
collimator
| Location: | China |
| Category: | Monitoring & Diagnostic Equipments>>X-Ray Equipment |
| Contact Preference: | |
| FOB Range: | |
| Minimum order Quantity: | |
| KeyWords : | Monitoring Equipments,X-Ray Equipment,200mA X-RAY MACHINE |