  • Fingertip Pulse Oximeter(ET-F)
    Parameters
    Two parametersSPO2, Pulse Rate.
    Waveforms:
    No waveform.
    Features
    1Tiny, light, "all-in-one" integrated clip design, easy for carrying;
    2LED screen with SpO2, PR and Pulse strength measurements;
    3Immediately, real-time spot-check;
    4Single button interface, easy for operation,
    5Common AAA alkaline or rechargeable batteries to support 3 continuous working hours;
    6Low battery power indicator;
    7Automatic power-off.
    Colors optional:Blue / Pink
    Specifications:
    SpO2
    Measurement range:35~100%
    Accuracy: ±2%(70~100%),0~69% unspecified
    Resolution:1%
    Pulse Rate
    Measurement range:30-250 bpm
    Accuracy:±2 bpm
    Resolution:1bpm
    Display Mode
    SpO2 display:1-digit of 2-segment and 2-digit of 7-segment red LED
    PR display:3-digit of 7-segment red LED
    Pulse strength display:A 6-segment red LED bar-graph
    Low battery power indicator:A red LED
    Environment Requirements
    Temperature:
    Working:0~40oC
    Transport and storage: -20~60 oC
    Humidity:
    Working:15~95%(non-condensing)
    Transport and storage:10~95%(non-condensing)
    Altitude:
    Working:86 KPa ~ 106 Kpa
    Transport and storage:50KPa ~ 106 Kpa
    Power Requirements
    Battery type: Two common 1.5V AAA alkaline or rechargeable batteries
  • Fingertip Pulse Oximeter(ET-F+)
    Parameters
    Two parametersSPO2, Pulse Rate.
    Waveforms:
    SpO2 Waveform
    Features
    1. 64k COLOR OLED Display, Four Direction adjustable
    2. SpO2 and pulse monitoring, and Waveform display
    3. Easy to use with one-key operation
    4. Small in size, and easy to carry
    5. Low voltage alarm display, Auto power-off
    6. Light weight of 55g(batteries included)
    7. Runs on standard AAA batteries

    Specifications:
    SpO2
    Measurement range: 35~100%
    Accuracy: +/-2%(70~100%), 0~69% unspecified
    Resolution: 1%
    Pulse Rate:
    Measurement range: 30-250 bpm
    Accuracy: +/-2 bpm
    Resolution: 1bpm
    Display Mode: 64k COLOR OLED Display, Four Direction adjustable
    Battery type: Two common 1.5V AAA alkaline or rechargeable batteries
    Environment Requirements
    Temperature:
    Working: 0 ~ 40oC
    Transport and storage: -20 oC ~ 60 oC
    Humidity:
    Working: 15 ~ 95 %( non-condensing)
    Transport and storage: 10 ~ 95 %( non-condensing)
    Altitude:
    Working: 86 KPa ~ 106 Kpa
    Transport and storage: 50KPa ~ 106 Kpa
  • Fingertip Oximeter(ET-60D)
    Product descriptionThe Fingertip Oximeter is applicable to hospital, home, community medical center and so on. It can monitor pulse oxygen saturation(SpO2) and pulse rate through patient's finger.
    Features:
    Light in weight and small in size
    Easy to carry and easy to use with one-key operation
    Can monitor SpO2 and pulse rate
    High accuracy and repetition
    Two AAA batteries are required, and the operation can be working with low power consumption
    Automatic power-off  if without signal longer for 8 seconds
    The continuous working time is 100 hours

  • Fingertip Oximeter(ET-60A)
    Product descriptionThe Fingertip Oximeter is applicable to hospital, home, community medical center and so on. It can monitor pulse oxygen saturation(SpO2) and pulse rate through patient's finger.
    Features:
    Light in weight and small in size
    Easy to carry and easy to use with one-key operation
    Can monitor SpO2 and pulse rate
    High accuracy and repetition
    Two AAA batteries are required, and the operation can be working with low power consumption
    Automatic power-off  if without signal longer for 8 seconds
    The continuous working time is 100 hours

  • Fingertip Oximeter(ET-60A)

    Product descriptionThe Fingertip Oximeter is applicable to hospital, home, community medical center and so on. It can monitor pulse oxygen saturation(SpO2) and pulse rate through patient's finger.
    Features:
    Light in weight and small in size
    Easy to carry and easy to use with one-key operation
    Can monitor SpO2 and pulse rate
    High accuracy and repetition
    Two AAA batteries are required, and the operation can be working with low power consumption
    Automatic power-off  if without signal longer for 8 seconds
    The continuous working time is 100 hours
  • Fingertip Oximeter(ET-60C)

    Product descriptionThe Fingertip Oximeter is applicable to hospital, home, community medical center and so on. It can monitor pulse oxygen saturation(SpO2) and pulse rate through patient's finger.
    Features:
    Light in weight and small in size
    Easy to carry and easy to use with one-key operation
    Can monitor SpO2 and pulse rate
    High accuracy and repetition
    Two AAA batteries are required, and the operation can be working with low power consumption
    Automatic power-off if without signal longer for 8 seconds
    The continuous working time is 100 hours