Patient Monitor direct from China - Etai Medical Co.,Ltd.
Home» products»Patient Monitor

Etai Medical Co.,Ltd.

Select to
Page 1 of 2
  • SPO2&TEMP Patient Monitor(ET-II+)
    Parameters
    Three ParametersSPO2TEMPPulse Rate.
    Waveforms
    Waveform: SPO2 waveform-PLETH
    Features
    1.Compact, small, light, easy for carrying and handling.
    2.LCD display of measurement and PLETH.
    3.Intelligent parameter monitoring interface.
    4.Audio and visual alarm.
    5.Storage and review of patients trend data up to 36 hours which is never lost even when powers off.
    6.Build-in rechargeable Ni/MH battery.
    7.Battery capacity indicator.
    8.Automatic power-off
    9.Patients trend can be transmitted to a personal computer for display, saving and printing.
    Color
    Blue or Pink can be selected.
    Standard accessories
    one SpO2 adult finger probe
    one TEMP skin face probe
    one charger
    one communication cable
    one software CD
    1. General
    Monitoring Parameters: SpO2PRPLETHPulse strengthTEMP
    Signal socketsSpO2 socketPR socketTEMP socketadaptor socketPC communication socket
    2. Display screen
    Type:128×64 dot matrix homochromy LCD
    Display area:45mm×30mm
    Backlight color: White
    LED:Dual-color LED (red/green)
    Size: 120mm×63mm×32mm
    Weight: 300gnot include probes and adaptor
    3. Features
    PLETH: The monitor can display PLETH waveform
    Intelligent parameter monitoring screen: The monitor automatically selects the parameter measurements to display according to the probes connected to the monitor.
    Audio and visual alarm: The speaker sounds the alarm and the parameters measurement flashes on the screen.
    Prompting: Icons of battery capacity, pulse sound switch and alarm sound switch.
    Power saving: The monitor will automatic shut down when no monitoring for 3 minutes.
    Trend: The monitor saves parameter measurements every 2 seconds and can store trend data up to 36 hours.
    Data storage: The saved data will never be lost even if the monitor is powered off.
    Communication: Transmitting the patients trend to a PC for display, observation, saving and printing.
    4. Electrical specifications
    Working Voltage: 6.0VD.C.9.0VD.C.
    AC power adaptor
    Input: 100-240VAC, 50/60Hz, 0.7A
    Output: 8V D.C., 800mA
    Internal battery
    Type: 2Ahr/6V Ni/MH rechargeable battery
    Run Time: 15-hour continuous operation with a new, fully charged battery (environment temperature is 25)
    Recharge time: 10 hours
    5. Environment
    Temperature
    Operation: 0°C ~ 45 °C
    Transportation and storage: -20°C ~ 60 °C
    Humidity
    Operation: 15% - 95 %( noncondensing)
    Transportation and storage: 10% - 95 % (noncondensing)
    Altitude
    Operation: 86 KPa ~106 KPa
    Transportation and storage: 50KPa~106 KPa
    6. Parameter Specifications
    SpO2
    Patient: Adult, child
    Range: 35% - 100%
    Resolution: 1 %
    Accuracy: 70% - 99%: ±2 %
    0% - 69%: Unspecified
    PR
    Range: 30 bpm ~250bpm
    Resolution: 1bpm
    Accuracy: ±2bpm
    TEMP
    Channel: 1
    Input: Body surface thermal-sensitive resistor temperature sensor
    Range: 050
    Resolution: 0.1
    Accuracy: ±0.2
  • SPO2&TEMP Patient Monitor(ET-II+AA)
    Parameters
    Three ParametersSPO2TEMPPulse Rate.
    Waveforms
    Waveform: SPO2 waveform-PLETH
    Features
    1.Compact, small, light, easy for carrying and handling.
    2.LCD display of measurement and PLETH.
    3.Intelligent parameter monitoring interface.
    4.Audio and visual alarm.
    5.Storage and review of patients trend data up to 36 hours which is never lost even when powers off.
    6.Common AA alkaline or rechargeable batteries to support 7 continuous working hours;
    7.Battery capacity indicator.
    8.Automatic power-off
    9.Patients trend can be transmitted to a personal computer for display, saving and printing.
    10.Suitable for adult, pediatric, infant and neonate patients.
    Standard accessories
    one SpO2 adult finger probe
    one TEMP Skin face probe
    one communication cable
    one software CD
    Specifications:
    Patient Range
    Adult, pediatric, infant, neonate patients
    Oxygen saturation (SpO2)
    SpO2
    Measurement range: 35%~100%
    Accuracy: ±2%(70%~100%) ,0%~69% unspecified
    Resolution: 1%
    Pulse Rate
    Measurement range:30 bpm -250 bpm
    Accuracy:±2bpm
    Resolution:1bpm
    Temperature (TEMP)
    Channel: 1
    Input: Body surface thermal-sensitive resistor temperature sensor
    Measurement range:0 oC50
    Accuracy:±0.2
    Resolution:0.1
    Alarm
    Mode:Audio and visual alarm
    Setup:User-adjustable high and Low limits
    Storage and Review
    36 hours SpO2 \PR\TEMP trend data with corresponding date and time
    Display Mode
    LCD screen:128×64 dot matrix homochromy LCD
    Measurements and information display
    LED indicator:Red and green Dual-color LED
    Red LED: insufficient battery power indicator
    Green LED: pulsating rhythm indicator.
    Operation Environment
    Temperature:
    Working:0 oC ~ 45oC
    Transport and storage:-20 oC ~ 60 oC
    Humidity:
    Working:15%~ 95%(non-condensing)
    Transport and storage:10 %~ 95%(non-condensing)
    Altitude:
    Working:86 kPa ~ 106 kPa
    Transport and storage:50 kPa ~ 106 kPa
    Power Requirements
    Battery type:common 1.5V AA alkaline or rechargeable batteries
    Run time:7 hours
    Dimension
    72 (W) ×130 (H) × 34 (D) mm

  • Multi-parameter Patient monitor(ET-9000P)
    The Multi-parameter Patient monitor can be used to monitor 6 vital signals such as patients ECG, Respiratory value, Temperature value, Non-Invasive Blood Pressure (NIBP) value, SpO2 value and Pulse Rate (PR).
    Features:
    12.1 high-resolution TFT display, which can indicate waves of ECG, respiratory rate (RESP) and pulse in detail;
    20 methods of automatic arrhythmia analysis, ST segment analysis;
    Can recall lapsed ECG wave in 5 minutes, and the wave can be frozen;
    Complete ECG monitoring through selection by different leads positioning;
    Up to 96 hour tendency statistics of SpO2, pulse rate and non-invasive blood pressure;
    Data memory of up to about 10 groups of VPC events for review and analysis;
    Memory and view of a list of up to 400 measures of non-invasive blood pressure, as well as heart     rate, temperature, respiratory rate and SpO2/pulse rate when the measure of blood pressure is taken;
    Unique SpO2 measuring device is used to ensure accuracy of the SpO2 and pulse rate measurements;
    Resistance against interference from defibrillator and electrosurgical knife. It may be used along with cardiac pacemaker;
    Blood pressure may be measured in the mode of adult/infant/neonate, which may be selected via the menu, to better suit the neonate or infant or adult patient;
    Information like printer, output waveform and text may be set as necessary;
    The modular equipment design allows the user to choose different monitoring parameters and form a monitor according to users own need;
    It may be networked with the center as a part of the central network.
  • Multi-parameter Patient monitor(ET-9000B)
    The Multi-parameter Patient monitor can be used to monitor patients ECG, Respiratory value, Temperature value, Non-Invasive Blood Pressure (NIBP) value, SpO2 value, Pulse Rate (PR) and other physiological parameters.
    Features:
    Convenient & swift knob operation. Portable designing, which allow operating when hanged on the wall or placed on the disk;
    12.1 high-resolution TFT display, which can indicate waves of ECG, respiratory rate (RESP) and pulse in detail;
    5-Channel ECG monitoring, 20 methods of automatic arrhythmia analysis, ST segment analysis;
    Can recall lapsed ECG wave in 5 minutes, and the wave can be frozen;
    Trend data analysis for 96 hours;
    Protection against interference from defibrillator, electrosurgical knife. It can be used along with cardiac pacemaker. Suit for various clinical conditions;
    The vehicle power supply is practicable with the optional accessory adapted ambulances;
    Can setup the network system in accordance with your requirement.
  • Multi-Parameter Monitor(ET-2000)
    1. Monitoring Parameters: ECG, NIBP, SPO2, Pulse Rate (Heart Rate), TEMP, Respiration
    2. Display in both Chinese and English.
    3. Multi-waveforms rolling(or renovating) display with adjustable display speed
    4. S-T segment synchronized detection and analysis ST
    Maximum 380-hour graphic and tabular trends of all parameters
    5. 400-set NIBP, HR, TEMP, SPO2, RESP data storage
    6. 50-min.ECG real time waveform and parameters storage and review

    7. Able to be connected with the central monitor station
    8. Inner High-definition thermal dot matrix recorder optional, which can output waveforms and characters
    9. Build-in rechargeable battery, long operating time

    Specifications
    ECG
    Whole-lead ECG cable, standard AAMI cable connector
    Lead selectionI, II, III ,avR; avL; avF; C (v1,v2,v3,v4,v5,v6)
    Gain selection×1/4, ×1/2, ×1, ×2
    Sweep speed12.5,25,50mm/s
    Bandwidth0.05-40Hz
    0.05-100Hz
    Calibration signal1mv
    ProtectionAgainst electrosurgical interference and defibrillation
    Heart Rate
    Measuring Range30-250bpm
    Accuracy ±1bpm
    Resolution 1bpm
    Alarm Mode: Audible and visual alarm

    RESP
    MethodResistance on chest
    Measuring Range0-120bpm
    Gain selection ×1/2, ×1,×2,×4
    Oxygen Saturation (SPO2)
    Measuring Range35-100%
    Accuracy ±2%70%-100%
    NIBP
    Method Oscillometric
    Mode : Manual, Auto, STAT
    Measuring interval in AUTO mode: 1-250(min)
    Measuring period in STAT mode: 5min
    Measuring type SYS, DIA, MEAN
    Measuring RangeSYS5.3-36 kPa
    DIA2.7-26.7 kPa
    MEAN4.0-29.3 kPa
    Temperature
    Measuring Range35.5-45.5
    Resolution: ­0.1
    Accuracy ±­0.2
  • Handheld Multi-para.Monitor(ET-I)
    Parameters:
    Five Parameters: ECG, NIBP, Pulse Rate, TEMP, SPO2.
    Waveforms:
    Two Waveforms: ECG waveform, SPO2 waveform (PLETH).
    Features:
    1.Handheld; Compact, light, easy for carrying and handling.
    2.Clear and bright LCD small screen real time display, Touch Screen.
    3.Can be display the data and the waveform in a screen, and also can be switch between ECG waveform and PLETH.
    4.English interface to simple read and handling.
    5.Build-in rechargeable Ni/MH battery, longtime operating time.
    6.Storage and review of patient trend data up to 36 hours which is never lost even when power is off.
    7.Audio and visual alarm.
    8.Battery capacity indicator.
    9.Automatic power-off.
    Standard accessories :
    one ECG cable with TEMP sensor
    one NIBP cuff with extend tube
    one SpO2 adult finger probe(soft)
    one charger
    one touch pen inside the model
    Technical Specifications
    ECG
    Input3-core ECG cable, standard AAMI cable connector
    Lead selectionI,II,III
    Gain selection:X1, X2, X4, X8
    Frequency response:
    None filter: 0.05100Hz (-3dB)
    filter: 0.540Hz (-3dB)
    Scan Speed: 12.5, 25, 50 mm/S
    ECG standard signal: 1mV square wave generated by hardware
    Heart rate
    Measure range: 20250 bpm
    Renew time: 1 time per beat
    Accuracy: 1 bpm
    Alarm limits range: Upper limits 80250bpm, Lower limits 40100 bpm
    Alarm mode: Audible and visual alarm
    NIBP
    Measure Method: Automatic oscillometric
    Average measure time: 40 seconds
    Repeat Cycles: 1, 2, 3, 5, 10, 15, 20, 30, 60 minutes
    Alarm limits range:
    SYS : Upper limits 120250 mmHg, Lower limits 60180 mmHg
    DIA : Upper limits 80150 mmHg, Lower limits 40120 mmHg
    MAP : Upper limits 100230 mmHg, Lower limits 50160 mmHg
    SpO2
    Measure Range: 35100%
    SpO2 Accuracy: 2%(7099%), 3%(4070%)
    Pulse Rate Range: 0254 bpm
    Pulse Rate Accuracy: 1 bpm

    Alarm limits range:
    SpO2 upper limits : 9599%
    lower limits: 8596%
    Pulse Ratekeep up with the heart rate

    Temperature
    Input : Apply the same sensor with ECG
    Measure range: 050
    Alarm limits range: Upper limits 3645 Lower limits 3438
    Measure accuracy: 0.1

    System specifications
    Alarm ON/OFF: controlled by general switch and parameter switch (two levels)
    Display mode: Homochromy LCD hand touch screen
    Waveform channel: Single channel
    Trend data: 36-hour HR, SpO2, TEMP,SYS, DIA, trend data.
    Dimensions: 114(D)X45(H)X150(W) mm
Select to
Page 1 of 2 << Previous 1
Go to Page