Medical Analyzer direct from China - Etai Medical Co.,Ltd.
Home» products»Medical Analyzer

Etai Medical Co.,Ltd.

Select to
Page 1 of 3
  • Semi-automatic Biochemical Analyser
    The instrument belongs to Chinese semi-automatic biochemical analyzer integrated the practical conditions of hospitals in China. The main components have been adopted with the imported parts and integrated the latest software program & advanced microcomputer technology with reliability & simplify. Its the latest upgrade product of semi-automatic biochemical analyzer.
    Characteristic
    Adopt imported concave raster as dispersion element with adjustable wavelength, little error of wavelength, high optics performance and nonadjustable computer drive raster.
    Inner microcomputer control & spectroscopic data processing;
    Large screen Chinese & picture display, man-machine conversation operation.
    Automatic printing, automatic storage, automatic wavelength setting, real time screen display.
    The Chinese printing of any item, any sample, comprehensive report, quality control report, quality control chart and item parameter
    Be tested with application performance rate method, two point method, linear end-point method, nonlinear end-point method, absorbency method, sample blank method, single & double wavelength method.
    Adopt whole-open program with 200 biochemical items & choice reagent.
    New storage method, can store item parameter & results permanently after power cuts.
    Fixed factor method for standard measuring method; one-time scaling.
    Automatic store 31 days quality control number, can make quality control statistic & display quality control chart.
    Display the standard curve of nonlinear end-point method & the reactive linear of performance rate method, survey the accuracy of sample results.
    Time setup, pump correction, printing color adjustment, error prompt.
    Main Technical Index
    Wavelength Range330-800nm
    Absorbency Measuring Range 0.3-3.0Abs
    Cross Contamination1%
    Temperature Control253037or room temperature
    Displayliquid crystal Chinese display
    Keyboard16 Keys Film Light-touch Key
    Printer: inner wide-row high-speed thermal printer can print Chinese format report.
    Interface: Standard RS-232C Interface

  • Semi-Auto Chemistry Analyzer
    Technic index:
    1Display:240*64 graphic LCD.
    2Test method: end point, double wavelength, Linear, Absorbance.
    3Wavelengths: 450, 505, 546, 578,630nm.
    4Absorbency range: 02.5Abs,Resolution:0.0001Abs,Stability:±0.005Abs.
    5Linear tolerance : ≤2.0.
    6Cross contamination≤1.0.
    7FlowCell: stainless stell with quartz window,measuring volume 2ul,optical path 10mm.
    8Temperature: 25,30,37±0.1,Temperature precision:±0.2.
    9Interface:RS-232.
    10Printer: Internal graphic thermal printer with character of low noise,high speed and long service life.External printer is also supported.
    11Paper width: 57mm.
    Test items:
    ALT/GPT   BUN   GLU       K      CK
    AST/GOT   UA     TCHO    Na    CHE
    TP     Cr      HDLC    CI    LDH
    ALB             LDLC    Ca
    TBIL            APOA1    Mg
    DBIL           APOB100   P
    ALP             TRIG
  • Semi-Auto Chemistry Analyzer
    Feature:
    1   Lamp is controlled by software, extend lamp life effective.
    2   200 tests can be programmed, memory for 5000 sample results.
    3   The reagent is open totally,the parameter of items can be setted freely.
    4   The device adopts high precision 1200 reticle raster.
    5   Display Dynamic curves at real time,teact the process visually.
    6   Perfect function,simple operation and maintainment.
     
    Technic index:
    1Test method: kinetic,end point, double wavelength, Linear, Absorbance, two points.
    2Lamp:Halogen tungsten lamp 6V/12W,life>3000 hours.
    3Wavelengths: 340,380,405,492,510,546,578,630nm.
    4Wavelength precision : ±1nm.
    5Absorbency range: 0∼3.0Abs,Resolution:0.0001Abs,Stability:±0.005Abs.
    6Linear tolerance: ≤2.0.
    7Cross contamination≤1.0.
    8FlowCell: stainless stell with quartz window,measuring volume 32ul,optical path 10mm.
    9Temperature: 25,30,37±0.1,Temperature precision:±0.2.
     
    Test items:
     
    ALT/GPT   BUN   GLU      K    CK
    AST/GOT   UA    TCHO    Na    CHE
    TP                Cr       HDLC    CI    LDH
    ALB            LD          LC       Ca
    TBIL        APOA1    Mg
    DBIL        APOB100   P
    ALP        TRIG
  • Biochemistry Analyzer
    1. FEATURES
    1 The instrument has a 7-wavelength static photometric group with 340, 405, 492, 510, 546, 578, 630 nm filters. It can select working wavelength by itself;
    2 The instrument can keep 100 programs in its memory. You can program parameters either beforehand or at current time based on your needs;
    3 The instrument can detect by the means of absorbance, kinetics, terminal, two-point, standard curve, blank comparing pipe and factor;
    4 The instrument can print detection report that makes it easy to analyses and persevere;
    5 The instrument will auto-check first after it is switched on.
    2. SPECIFICATIONS
     Range of working wavelength:   340nm~700nm;
     Range of absorbance: 0∼2.5A;
    Accuracy error:
    AbsorbanceA     0.011.0  1.0∼2.5
    Accuracy Error% ±0.01     ±0.02
    Cross pollution rate:      <=1%Aspiration volume 800ul;
     Test temperature:              37,30,25;
    Accuracy error of test temperature: ±0.2;
    Volume:  565×410×290mm;
    Weight: 9Kg;
     Fuse:   φ5×20 2A   2
    3 Work Conditions
    1 Temperature:10∼30;
    2 Relative humidity: <=70%;
    3 Power supply: 220×1±10%V, 50×1±2%Hz;
    4 Input power:  160VA;
    5 Warm-up time:  10min;
    6 Keep away from strongly electromagnetic field;
    7 Avoid direct irradiation by strong light;
    8 Avoid dust and shake. There must be no caustic gas such as hydrochloric acid in air;
    9 Power supply must be earthed perfectly.
     
  • Blood Coagulation Analyzer 4 Channel
    14 positions for reagents.
    24-channel analyzer with optical clot detection.
    3simple operation,holding the manifestation dynamic state curve and the test item and data greatly.
    4Complete report form(time, specific value, INR, density, reference value)
    537 heat and 2-8 refrigerate for reagents.
    6Quickly, accurate, the dependable adoption deducts this bottom method, can all examine to the fat blood and the jaundice.
    7Can synthesize to print four sets of contrast diagram text data inside placing a printer.
    Clinical Use:
    1Clotting Assays
    2PT
    3APTT
    4TT
    5FIBRINOGEN
    6FACTORS (INTRINSIC & EXTRINSIC)
    7PROTEIN C
    8PROTEIN S
    9ATROXIN TIME
    10LUPUS ANTICOAGULANTS
    11APC-R
  • Semi-Auto Urine Chemistry Analyzer
    1High-bright luminescence technology,reduce molestation from environment.
    2Reagent strip is opened.
    3Keep results automatically.
    4Identify urine reagent strip deposition automatically.
    5Every function can be modified.
    6Qualitative testing index,auto-adjusting.
    7Various report modes,number or +/-.
    Technical Index:
    1Display: 240*128 graphic LCD.
    2Method: Dual-wavelength Reflectqance Photometer.
    3Test Wavelengths: 450nm,550nm,650nm.
    4Test Rate: Max 120 samples/hour.
    5Memory: 1000 sample results.
    6Printer: Internal graphic thermal printer with character of low noise,high speed and long service life.External printer is also supported.
    7Interface: RS232.
    8Test items: Leucocyte(LEU),Nitrite(NIT),Urobilnogen(URO),Protein(PRO),pH(pH),Specific GravitySG,Blood(BLD),Ketone(KET),Bilirubin(BIL),Glucose(GLU).
Select to
Page 1 of 3 << Previous 1
Go to Page