  • X-ray film processor(ET380-E)
    Technology Date:
    Developed film size : 5" x 7"~ 14" x 17"
    Max. developing width : 356mm (14" )
    Channel volume : 9L
    Developing speed : 90S ~ 180S at option
    Developing temp.: 28 ~ 35 at option
    Developing capacity : 150 pcs/h
    Power source : AC220V, 50/60Hz
    Power : 1.8kw
    Product Characteristic:
    Equipment Figure: New designed body and beautiful outlook. Taking films from basket besides machine.
    Equipment Frame: Narrow frame make operate easily and break, install simply. Easy to clear, check and repair.
    Install & Adjustment: Install very freely, fit full dark room or half dark room.
    Film-Sending Frame: For "U" shape continue rolling and no touch guide system design, no risk of film jamming or scratch and body shadow.
    Through Full Developing, fixing and washing, image make very clear and no change for long time.
    Critical Parts: The rollers' material can resist high-temperate and crystallization. No change shape and swell for using long time.
    Circuit Control: Microprocessor controls heating, automatic check and touch films, replenishing chemicals.
    Energy-Saving: Keep sleep situation when no films need process after a while. Stop heating and rolling, then cut enter water. This can save energy for max limit.
  • X-ray film processor
    Technology Date:
    Developed film size :5" x 7"~14" x 17"
    Max. developing width :356mm (14")
    Channel volume :9L
    Developing speed :90S ~ 180S at option
    Developing temp. :28 ~ 35 at option
    Developing capacity :150 pcs/h
    Power source :AC220V, 50/60Hz
    Power : 1.8kw
    Product Characteristic:
    Equipment Figure: New designed body and beautiful outlook. Taking films very expediently due films turn above.
    Equipment Frame: Narrow frame make operate easily and break, install simply. Easy to clear, check and repair.
    Install & Adjustment: Occupy small ground, install very freely, fit full dark room or half dark room.
    Film-Sending Frame: For "U" shape continue rolling and no touch guide system design, no risk of film jamming or scratch and body shadow. Through full developing, fixing and washing, image make very clear and no change for long time.
    Critical Parts: The rollers' material can resist high-temperate and crystallization. No change shape and swell for using long time.
    Circuit Control: Microprocessor controls heating, automatic check and touch films, replenishing chemicals.
    Energy-Saving: Keep sleep situation when no films need process after a while. Stop heating and rolling, then cut enter water. This can save energy for max limit.
  • X-ray film processor(ET435-T)
    Technology Date:
    Developed film size : 5" x 7"~14" x 17"
    Max. developing width : 430mm (17")
    Channel volume : developer 4.3L, fixer 3.6L, water 3.6L
    Developing speed : 180S or 100-180S at option
    Developing temp. : 28 --35 at option
    Developing capacity : 100pcs/h
    Power source : AC220V, 50/60Hz
    Power : 1.5kw
    Product Characteristic:
    Produce technology: The out casing are made of plastics mould. It's very strong, durable and anti-corrode.
    Equipment Figure: New designed small body and beautiful outlook. Taking films very expediently due films turn above.
    Install & Adjustment: Occupy small ground, install very freely, fit any dark room and put it on the table directly.
    Film-Sending Frame: Safe Film-Sending systems come from one whole design, no films jamming or scratch.
    High-Effect Drying: New wind route technical can blow all little water spot on the films. At the high net surrounding, can get distinct clear cut films.
    Film-sending Board With Cover: Light and close film-sending cover board, operator may open lamp and leave after enter films. This design make work easily and improve work effect.
    Critical Parts: The rollers' material can resist high-temperate and crystallization. No change shape and swell for using long time.
    Circuit Control: Microprocessor controls heating, automatic check and touch films, replenishing chemicals.
    Energy-Saving: Keep sleep situation when no films need process after a while. Stop heating and rolling, then cut enter water. This can save energy for max limit.
  • 300mA X-ray machine

    Application:
    Routine Radiography
    Bucky Radiography
    Composition:
    Control desk     high-voltage generator     high voltage cable    X-ray tube assembly
    Radiographic table    -pillar of X-ray source       collimator       
    Chest film stand (optional composition)
     
    Feature:
    1. One table, one tube
    2. Single-phase, full wave, high voltage rectification
    3. Rotary anode x-ray assembly and tangential pipe sleeve IEC plug and plug base
    4. Supply voltage. radiography KV, infinitely variable control and electric mechanism
    5. Equipped with capacity protective circuit, and KV mAs sectional and graduated interlock protection
    6. Controller is equipped with electric autotransformer, easy to adjust
    7. Equipped with the manostat for filament of X-ray tube and equipped with space-charge compensator
    8. Adopt the digital circuit timer, grade according to R10 priority coefficient and can control time exactly
    9. High-voltage primary uses the zero controlled circuit of silicon-controlled rectifier of large power

  • 200mA X-ray machine

    Application:
    Routine Radiography
    Bucky Radiography
    Composition:
    Control desk   
    high-voltage generator   
    high voltage cable  
    X-ray tube assembly
    Radiographic table
    -pillar of X-ray source
    collimator
     
    Characteristics:
    1. The power supply voltage V and KV are infinitely variable control.
    2. The machine is equipped with mA, KV and S interlocking protecting device of subsections and grades.
    3. The machine is equipped with the protection device of X-ray filament manostat, space charge compensation and anode start.
    4. Power supply voltage, radiographic KV and mA display separately and are observed easy.
    5. The machine with no top and bottom track is installed and operated easy.
    6. Transverse moving of upright post, lengthways moving of arm and rotation of X-ray tube unit are all equipped with electromagnetism braking device.
    7. Diagnostic bed, which is equipped with electromagnetism braking device, can move not only transversely but also lengthwise.

  • 200mA X-ray machine

    USE

    Roentgenoscopy; Digestive track spot film photograpy; General photograpy; Filter-ray device photograpy

    MAIN TECHNICAL PARAMETER
    1. Single bed and single tube
    2. Rotary anode X-ray tube unit and tangential pipe sleeve.
    3. monophase full-wave rectification high-voltage generator.
    4. Supply voltage V, roentgenoscopy and photograpy kV, infinitely variable control and electric mechanism.
    5. Equipped with capacity protective circuit,and kV mAs sectional and graduated interlock protection.
    6. Equipped with the manostat for filament of X-ray tube and equipped with space-charge compensator.
    7. Adopt the digital circuit timer, grade according to R10 priority coefficient and can control time exactly.
    8. Equipped with the digital circuit device for roentgenoscopy time accumulation.
    9. Examining bed is of electric back rotation, with external balance structure and with vibrating filter-ray device.
    10. The spot film device of luminescent screen can hold the film jacket of various sizes and solenoid valve locking.
    11. Upright post is of top and bottom track. It moves lightly.
     
     
    ITEM CONTENT  INDEX 
    Fluoroscopy voltage 40100kV be adjustable continuously 
    current  0.55mA 
    Photograpy voltage 40100kVbe adjustable continuously 40125kV be adjustable 
    current small focus 50mA and big focus 30 100 150 200mA,five grades 
    spot film  150mA( fixed )
    time 0.046.3s 23 grades together 
    High-voltage generator  capacity 20kVA( instantaneous ) 
    Max dc output voltage  100KV 125KV  
    Max dc output current  200mA 
    X_ray tube  model  XD51-20.40/100 XD51-20.40/125  
    focus  1×1mm 2×2mm 
    Examining bed  rotary angle  +90° 0 ° -10° 
    movable range of spot film device(stomach and intestines photograpy)  lengthwise 580mm
    transverse ± 90mm
    pressure down 300mm
    specification of spot film  127×177.8mm(5×7) 
    203.2×254mm(8×10)
    254×304.8mm(10×12) 
    279.4×355.6mm(11×14) 
    filter-ray grid characteristic  N28 
    converging distance  fo 100cm 
    grid proportion  r8 
    distance between bed face and film  70mm
    collimator manual single blade 
    Upright adjusting scope(distance between top and bottom track)  2800-3400mm 
    move lengtwise (along top and bottom track)  3100mm
    move transverse(along horizontal arm ) 800mm( from bulb focus to he centre of upright post)
    move up and down (along upright post) 3251830mm( from bulb focus to groud) 
    Power supply  Voltage  380V/220V 
    Frequency 50Hz ± 0.5Hz 
    Inner resistance  380V:0.9 Ω ,220V:0.3 Ω 


    UNIT CONFIGURATION
     
    Control desk     high-voltage generator unit    

    high voltage cable      X-ray tube assembly

    Radiographic table-pillar of X-ray source       

    collimator