CMS 9000 multi-parameter monitor (sell offer)
Home » Sell Offers » CMS 9000 multi-parameter monitor

Contec medical

CMS 9000 multi-parameter monitor

Posted Date: 2009-09-264

Expiry Date: 12 months

Description

Features

■ Color TFT Screen, waveform up to 8 channels

■ Light and portable with build-in rechargeable battery

■ UP to 10 kinds of monitor parameters

■ Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis
■ 72 hour storage and review of trend grams and tables, 40 second review of olographic
wavefo rms.
■ Built-in recorder(option)


■ All-round monitor of adult ,pediatric and neonatal.

■ Electrosurgical unit and defibrillation protected

■ Standard parameters: ECG, NIBP, SPO2, Respiration, Temperature, Pulse rate

■ Option parameters: EtCO2, CO, IBP, Thermal Printer

ECG

■ 5-lead or 3-lead selectable

■ Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C

■ Lead selection: I; II; III; avR; avL; avF; Vx; CAL

■ Gain selection: 12.5mm/s, 25mm/s, 50mm/s

■ Accuracy: ?bpm or ?%, whichever is greater

■ Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation

■ Calibration signal: 1mV?%

■ Operation modes: Diagnostic, Monitor, Surgery

■ Alarm range: Adult: 15-300bpm

■ Pediatric/Neonatal: 15-350bpm

■ Alarm range: -2.0mV~2.0mV

■ S-T detection: YES, Arrhythmia analysis: YES

■ Alarm: YES, audible and visual alarm, alarm events recallable

NIBP

■ Method: Oscillometry

■ Operation modes: Manual/Automatic/STAT

■ Measurement unit: mmHg/KPa selectable

■ Measurement types: Systolic, Diastolic, Mean

■ Measurement range: Adult: 10-270mmHg

■ Over-pressure protection: YES

■ Resolution: 1mmHg

■ Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10

■ Alarm: Systolic,Diastolic,Mean

SpO2

■ Measurement range: 0-100%

■ Accuracy: ?digit (70~100%);

■ 0~69% unspecified

■ Alarm range: 0-100%

Respiration

■ Method: RA-LL impedance

■ Pediatric/Neonatal: 6-150rpm

■ Alarm range: Adult: 6-120rpm

■ Pediatric/Neonatal: 6-150rpm

■ Apnea alarm: YES

Temperature

■ Resolution: 0.1℃

■ Channel: Dual-channel

■ Alarm range: 0-50℃

Option:

EtCO2

■ Measurement Mode: Side-stream or mainstream

■ Measurement range: EtCO2: 0-99mmHg

■ Accuracy: CO2 concentration

■ Apnea alarm: YES

CO

■ Method: Thermo-dilution

■ Measurement range: CO: 0.1-20 lit./min.

IBP

■ Channel: 2 channels

■ Pressure transducer: Sensitivity: 5( mV/V/mmHg)

■ Transducer sites: ART, PA, CVP, RAP, LAP, ICP

■ Alarm range: -10~300mmHg


Other Information
Location: China
Sell Type: Sell
Category: Monitoring & Diagnostic Equipments>>Multi-Parameter Monitor
Contact Information
Please Sign In to view this member's contact information. Not a Industry-medical.com member yet? Join Now For Free!