Product catalog - AMBULANC(SHENZHENZ)TECH.CO.,LTD.
Home » Products »

AMBULANC(SHENZHENZ)TECH.CO.,LTD.

Product

Product Group List

Select to
Page 5 of 5
  • Digital Thermometer
    Specification:
    Body temperature
    Range:32.0-42.0
    Resolution: ±0.1 or ±0.2
    Fever alarm function

  • ECG
    Features
    Designed with a high-resolution thermal printer featuring 8dot/mm vertical resolution and 40dot/mm horizontal resolution(at 25mm/s) speed and filter as well as related marks.
    Simultaneously 12 lead signal acquisition.
    Realtime 2 channel print out.
    Digital filter to prevent baseline drift and automatic positioning of the baseline provide accurate ECG trace.
    Able to detect and alarm on electrode disconnection.
    Isolated input circuit guarantees safety standard in compliance to Class I type CF.
    AC/Rechargeable battery supports continuous operation when AC power supply is not available. For the battery operation, equipped with a battery charger and a system for battery capacity management and protection. Rechargeable battery supporting more than 50 patient examinations
    Compact size.
    LED indicator and LCD display show operation status of the unit.
    Backlit high resolution graphic LCD, display 2 channel ECG waveform.(1020G)


    Specifications:
    Lead: Standard or Cabrera 12 leads, Simultaneously 12 leads acquisition
    Input Circuit: Isolated input circuit with protector against pace-make and defibrillation
    Patient Current Leakage: <10uA
    Input Impedance: >50Mohm
    Frequency Response: 0.05 ~ 150Hz
    Time Constant: > 3.2s
    CMRR: > 80dB; > 100dB (filter in use)
    Filter: EMG: 25Hz (-3dB) or 35Hz (-3dB) AC: 50Hz(-20dB) DFT: 0.5Hz
    Sensitivity: 5, 10, 20mm/mV±5%
    Sampling Rate: 1ms
    A/D Converter: 12bit
    Recording Mode: Thermal array printer,8 dot/mm(Vertical) 40 dot/mm(Horizontal, 25mm/s)
    Paper Speed: 5, 10, 25, 50mm/s ± 5%
    Paper Size: 80mm,20m, roll type
    Safety Level: Class I, type CF
    Power Requirements: AC: 220V±10%, 50Hz±5%, 50VA Built-in NiMH battery,12V
    Dimension: 285mm×200mm×50mm
    Weight: less than 2.5Kg
    Standard Accessories:
    Patient Cable: 1pc
    Limb Electrod: 4pcs/set
    Chest Electrodes: 6pcs/set
    Power cable: 1pc
    Paper Shuft: 1pc
    Recording Paper: 1 roll
    Fuse: 2pcs
    Built-in Battery: 1pc
    Operation Manual: 1 copy


    Package Information: Dimension of Packaging:
    400mm(L)×230mm(W)×80mm(H)
    Gross Weight:4KGS

  • Patient monitor

    Compact and portable, allowing for uninterrupted monitoring with built-in battery
    Display of NIBP, SpO2 and Pulse Rate via LED with high brightness
    3 configurations selectable
    Manual/auto/continuous measurement of NIBP
    Auto audible and visual alarms
    Storage of NIBP data up to 900 groups or SpO2 data up to 24 hours
    External printer available
    Applications from adults to neonates


    --------------------------------------------------------------------------------
    Standard Configuration:
    A. NIBP/PR
    B. NIBP(Nellcor Module)/PR
    C. SpO2(Nellcor Module)/PR
    Standard accessories: NIBP tube and Adult cuff, Adult reusable SPO2 sensor, Temp probe, Built-in rechargable battery.

    --------------------------------------------------------------------------------
    Option:
    External Termal Recorder

    --------------------------------------------------------------------------------
    Technical Specifications
    Dimension and Weight
    Dimension: 180 mm(W) X 60mm(H) X 220mm(D)
    Weight: 1.8kgs

    Operation Environment
    Power Requirements: AC 100-250V, 50/60 Hz

    Application Scope
    Adult, child and neonatal

    Performance Specifications
    Display: LED
    Battery: Rechargeable, lasting for maximum 2 hours
    NIBP
    Method: Oscillometric
    Operation modes: Manual/Automatic/Continuous
    Meausrement unit: mmHg/Kpa selectable
    Automatic measurement interval: 1,2,3,5,10,30,45,60,90,120,180,240,480 minutes
    Measurement Range:
    Adul/Pediatric: 15-255mmHg
    Neonate: 10-135mmHg
    Resolution: 1 mmHg
    Over-pressure protection: Adult/Pedicatric Mode 290mmHg
    Neonate: 145mmHg

    SpO2
    Measurement range: 0-100%
    Resolution: 1%
    Accuracy: ±1% (90-100%)
    ±2%(70-89%)
    Alarm range: 1-100%


    Pulse Rate
    Range: 0-254 bpm
    Resolution: 1bpm
    Accuracy: ±1bpm
    Alarm Range : 0-254bpm
    Package Information
    9200M5 without recorder
    Carton Dimension: 410 mm(L) X 290 mm(W) X 200 mm(H)
    Gross Weight: 3.3 kgs


Select to
Page 5 of 5    5 Next>>
Go to Page