Product catalog - Guangzhou Yueshen Import & Export Co., Ltd
Home » Products »

Guangzhou Yueshen Import & Export Co., Ltd

Product
Select to
Page 1 of 1
  • Semi-Auto Chemistry Analyzer
    Method: Kinetic, End-point, Linearity end-point, Non-linearity end-point, Absorbency,
    Sample blank, Multi-standards, Velocity, Calculation, Two-point, Double wavelength
    etc.
    7 wavelengths optic system avoiding outer disturbance, Wavelength range: 340nm-700nm;
    Quality control: Quality control for all tests, Statistic and print quality control
    parameters automatically with QC curves;
    Every test can do high.medium.low three groups quality control;
    Program: Add or delete test items easily according to the condition, modify the test
    parameters;
    Display Dynamic curves at real time, visually react the process;
    The print content includes comprehensive hospital's name and sample's materials;
    Dormant automatically for the lamp to prolong it's lifespan;
    Input 8 standard curves at most in testing with multi-standard method;
    The reagent is open;

  • Hematology Analyzer
     1) Function: just use 9.6μL of sample, really implement the micro-counting, not
    need pre-dilution outside the machine
    2) Advanced technology of back flush and refluence, keep away from clog. Automatic
    sample probe cleaning (inside and outside), without paper wipe. Automatic pipeline
    soak with operating the shut-down procedure, removing the protein adhering the
    counting aperture
    3) Fully closed reagent, reduce the pollution of reagent. Auto-lever detection, caution
    for change
    4) Detection parameter:
    a) White blood cell count (WBC)
    b) Lymphocyte number (LYM#)
    c) Mid-cell number (MID#)
    d) Granulocyte number (GRAN#)
    e) Lymphocyte percent (LYM)%
    f) Mid-cell percent (MID)%
    g) Granulocytes percent (GRAN)%
    h) Red blood cell count (RBC)
    5) Technical specifications:
    a) Detection principle: electrical resistance for cell counting, cyanide-free
    photometric method for HGB
    b) Detection parameter: 3-part differentiation of WBC, 20 parameters
    c) Work mode: double channels counting and independent hemoglobin
    blood detect system
    d) Volume of sample: 9.6μL
    e) Micro-aperture: WBC: 100μm; RBC/PLT: 80μm
    f) Throughput: >60 samples/hour, can run round-the-clock,
    automatic stand-by and active
    g) Classifying method: fixed terminus, float terminus, artificial adjustment
    h) Volume of reagent:
    ¢¡) Diluent: 20ml/sample
    ¢¢) Lyse: 0.3ml/sample
    ¢£) Cleaner: 4ml/sample
    ¢¤) Carryover: WBC, PLT, HGB<2%, RBC<1%
    6) Quality control: L-J QC diagram, -x, SD, CV%
    7) Result storage: automatic storing of all 12,000 sample parameters +3 histograms
    8) Reference value defining: adult man, adult woman, child, infant, common, and 3
    kinds of user self-defining
    9) Display: color LCD display with 10.4", resolution: 640 x 480
    10) Information: including many kinds of information such as: name, department,
    and inspector
    11) Input/output: parallel printer interface, RS232, keyboard interface,
    mouse interface
    12) Operation environment:
    a) Temperature: 15 - 35°C
    b) Humidity: 10 - 90%
    c) Power requirement: AC220V+10%, 50/60+1Hz or AC110V+10%, 50/60+1Hz
    d) Weight: 25kg
    13) PE-6000 Reagent List:
    Hemoglobin (HGB)
    Hematocrit (HCT)
    Mean cell volume (MCV)
    Mean corpuscular hemoglobin (MCH)
    Mean corpuscular hemoglobin concentration (MCHC)
    Red blood cell distributed width- standard deviation (RDW £­ SD)
    Red blood cell distributed width- coefficient of variation (RDW £­ CV)
    Platelet count (PLT)
    Mean platelet volume (MPV)
    Platelet distributed width (PDW)
    Plateletcrit (PCT)
    Plateletcrit-large cell ratio (P£­LCR)
    colorized volume distribution histogram of WBC (WBC Histogram)
    colorized volume distribution histogram of RBC (RBC Histogram)
    colorized volume distribution histogram of PLT (PLT Histogram)

  • Uritest 300 Urine Analyzer
     Uritest series of urine reagent strip for your free selection
    The addition Ascorbic Acid item increase the reliability of the measurement
    Low noise and long life thermal printer
    LCD screen, microcomputer
    RS232 interface, interfacing to the computer is convenient
    Automatically remove the waste reagent strip
    On-line software is available

  • Fully Auto Hematology Analyzer

          Methodology: Electrical resistance for counting,hemiglobincyanide method and SFT method for hemoglobin

          Parameter: 3-part differentiation of WBC;20 parameters and 3 color histograms (WBC,RBC,PLT)

          Sample volume: 9.6µL for Venous mode,20µL for prediluted mode

          Throughput: More than 30 samples per hour,operatable 24 hours a day,auto sleeping and waking-up functions

          Storage:up to 12000 sample results including histograms can be stored, convenient for inquiry and management of history data

          Operation langue:English

          Species of animals:Dogs,Cats,Horses,Pigs,Cattles,Goats,Monkey,Mouse etc. Additionally, four user-defined test modes are provided to meet the needs of various users

          Quality Control:L-J curve,X SD  CV

          Calibration mode:Relatively independent manual calibration and auto calibration in three detecting modes

          Display:Large-sized color LCD display, resolution of 640×480 dot

          Information:Multiple samples and users character input

          Interface: 1 parallel interface,2 USB interfaces,2 PS/2 interfaces,2RS232 interfaces applicable to networking,1VGA interface

          Power supply:AC100-240V  50/60HZ


  • auto chemistry analyzer
     INTRODUCTION:AMS-18 is a highly sophisticated, smartly designed bench-top Analyzer
    for Clinical Chemistries and Immunoassays. State of the art electronics and very
    simple mechanics with few moving parts, will assure you utmost efficiency and
    reliability in day by day performance.Patients and tests are automatically selected.
    It does optimize work load running up to 18 different chemistries per patient
    at a time.The software allows the operator to program the entire daily routine
    without dividing it into different batches.

Select to
Page 1 of 1 << Previous 1 Next>>
Go to Page