Product catalog - Tsingtao Unicom-Optics Instruments Co., Ltd.
Home » Products »

Tsingtao Unicom-Optics Instruments Co., Ltd.

Product
Select to
Page 1 of 5
  • Hematology Analyzer PE-6300
    Hematology Analyzer (PE-6300)
    PE-6300 auto hematology analyzer is an easy operation and owns perfect blood analytical system with 3-part differentiation of WBC. Its advantaged at digital technology, float discriminator, intelligent flush, time & volume quantitative technique guaran - tees the precise result.
    Built-in sample processor and test unit
    High precision microanalysis technology
    Low consumption of blood sample volume:Venous9.6 µL,prediluted 20 µL for twice
    High voltage zap with monitor in real time,recoil flush technology
    Double convolution and intelligent fitting technology
    Intelligent float discriminator, manual adjustment
    Windows interface
    Graphical buttons, mouse & keyboard opration
    Input various information, induding name, office, sender etc.
    Real-time assistance and operation guide
    Professional calibration programe and comprehensive QC project
    Various printout formats
    20 parameters+3 color histograms
    With three detecting modes: Venous, Capillary and prediluted, accurately detect the following 23 parameters in any mode:
    WBC,LYM#,MID#,GRAN#LYM%,GRAN%,RBC,HGB,HCT,MCV,MCH,MCHC,RDW-SD,RDW-CV,PLT,MPV,PDW,PCR,P-LCR.
    Color histograms:WBC,RBC,PLT
    Technical Specifications
    Principle:
    Electrcal resistance for counting, hemiglobincyanide measurement and SFT method for hemoglobin

    Parameter:
    3-part differentiation of WBC
    20 PARAMERERS + 3 color histograms (WBC,RBC,PLT)
    Sample Volume:
    Venous:9.6µL
    Capillary:9.6µL
    Prediuted:20µL
    Working Mode:
    Counting passage detection+independent HGB measurement system;
    Operation Mode:
    Windows interface, graphical buttons, keyboard & mouse opration
    Aperture Diameter:
    WBC/RBC/PLT:80µm
    Data Storage:
    Up to 12,000 results with histograms
    Quality Control:
    L-J curve,X SD CV
    Calibration Mode:
    Relatively independent manual calibration and auto calibration in three detecting modes.
    Cross Contamination Ratio:
    WBC,RBC,HGB<0.5%,PLT<1%
    Performance:
    Paramerer
    Repeatability(cv%)
    Liner Range
    WBC
    ≤3.0%(7.0-15.0)
    0.0-99.9×103/µL
    RBC
    ≤3.0%(3,50-6.00)
    0.0-99.9×106/µL
    HGB
    ≤2.0%(11.0-18.0)
    0-30.0g/dL
    MCV
    ≤1.0%(80.0-110.0)
    40-150ft
    PLT
    ≤6.0%(100-500)
    0.0-99.9×103/µL
    Display:
    8.4 High Resolution LCD monitor
    Information:
    Input various information, including name, office, sender etc.
    Interface:
    USB,PS/2, parallel interface,RS-232 ports for network
    Printout:
    Internal rapid thermal printer, external inkjet printer, various printout formats
    Working Engcironment:
    Temperature:1535;Humidity:10%-90%
    Power supply:AC100-240V 50±1HZ

  • Laboratory furniture YLS-303
    Laboratory furniture (YLS-303 )
    1. Wood part
    Plate of table surface: Physical and chemical plate with 25mm thickness, imported from USA
    Other plate: Medium Density Melamine Plywood with 16mm thickness
    Manufactured by German woodworking machinery with fine manufacturing technology

    2. Circuit part
    Main AC/DC power supply of this laboratory is controlled by teacher with drawer model.
    Two universal AC220 safety power sockets for each students experiment table.

    3. Water supply system
    Water supply for students can be controlled by teacher with electromagnetic valve.
    Water tank: PVC material or Ceramic material for optional
    Water tap: Three associations tap, goose neck model
    Water pipes: UPVC material
    5. Ventilated system
    Centrifugal fan: UPVC, 5.5KW, 0-16800r/m, 0-18500 m3/h, Air changes 0-20 times/h
    Muffles: To decrease the noise, muffles are installed in the absorbing pipes which are under every student experiment tables, also muffles are installed at the input and output of centrifugal fan.
    Air absorbing types: Polluted air is absorbed by the absorbing cover which is mounted on the table surface, the lead into the underground air pipes, and the exhaust outside of the laboratory by centrifugal fan.
    Flexible type of support of absorbing cover
    6. Specifications
    Items
    Part name
    Description
    Unit
    Quantity
    1
    Teacher table for demonstration
    2800mm×700mm×900 mm
    Set
    1
    2
    Student table for experiment
    2800mm×600mm×780 mm
    Set
    9
    3
    AC/DC power supply device for teacher
    Set
    1
    4
    AC/DC power supply receiving box for student
    Set
    19
    5
    Teacher controller console, with AC/DC power transmitting device
    Set
    1
    6
    High grade Sink
    Resistant most chemicals
    340X400X200mm
    Set
    10
    7
    Three associations tap
    Goose neck model
    Set
    10
    8
    Teacher chair
    Swivel chair
    Set
    1
    9
    Student stool
    Plastic & steel structure
    Set
    36
    10
    All the power wires and power wire protecting pipes for this laboratory
    Ø 20mm /PVC
    Ø 0.20mm/copper core wire
    Set
    1
    11
    Power distribution box
    Set
    1
    12
    Air volume distributor
    Set
    37
    13
    Muffler for absorbing cover
    Set
    37
    14
    Muffler for centrifugal fan
    Set
    1
    15
    Air pipes outside of laboratory
    φ400m
    Set
    1
    16
    Underground air pipes in laboratory
    φ400φ200φ100mm
    Se
    1
    Indoor type of ventilation device
    Set
    1
    1
    Shock absorber for centrifugal fan
    Set
    19
    Input flexible linking pipes and output flexible linking pipes for centrifugal fan
    Set
    1
    20
    Muffle for input and output of centrifugal fan
    Set
    1
    2
    Cover for anti-rain, which is mounted at the end of the outdoor air pipes.
    φ800mm
    Set
    1
    22
    Centrifugal fan with adjustable speed
    UPVC, 5.5KW, 0-16800r/m, 0-18500 m3/h, Air changes 0-20 times/h
    Set
    1
    23
    Elbow bend
    UPC
    Set
    1
    2
    Input tuyere and Leading tuyere
    Set
    1
    2
    Water supply and drainage system
    Set
    26
    Hidden type of absorbing cover
    Set
    37
    27
    Controller for air value and air speed
    Set
    1
    28
    Water valve, electromagnetic type
    Set
    1
    7. Gas supply system (optional)
    Gas
    Gas tap and gas pipes are optional accessories.
    Reagent rack
    Φ35 mm, two pieces.

  • RAY Machine(GDX-50A)
    RAY Machine(GDX-50A)
    Output image size: 50mm
    Survey thickness:280mm
    Resolving power:>4LP/mm
    Screen lighteness:>40cd/m2
    X tube high pressure:35-75kV
    X tube electricity:0.2-0.5mA
    X ray leak speed: <5mR/h
    Net weight:3.6kg
    Power:80W
    Power Supply:
    220V50HZ


  • UV-Visible Spectrophotometer (UV-4100PC)
    UV-Visible Spectrophotometer (UV-4100PC)
    Unicom-Optics UV-4100PC Double Beam UV/VIS Spectrophotometers can meet the broad requirements of pharmaceutical, biochemical and clinical lab applications as well as routine applications such as quantitative analyses, kinetics, spectrum scanning, multiple components and DNA/Protein.
    UV-4100PC Double Beam UV/VIS Spectrophotometers must link with PC. (PC not included).
    It provides excellent performance for measurements in the range of 190nm to 1100nm. It is suitable for pharmaceutical, biochemical and clinical lab applications as well as routine applications such as quantitative analyses, kinetics, spectrum scanning, multiple components and DNA/Protein. PC Windows® application software makes this instrument versatile.

    Optical Specifications

    Wavelength Range 190 - 1100 nm
    Spectral Bandwidth 1 nm
    Monochromator
    Double beam C-T type, grating 1200 lines/mm
    Wavelength Accuracy ± 0.3 nm
    Wavelength Repeatability ±0.2 nm
    Wavelength Calibration
    Automatic at start
    Light Source
    Tungsten Halogen Lamp
    Deuterium Lamp
    Detector
    Solid Silicon Photodiode
    Photometric Readout
    UVCON Software
    Photometric Range
    0 - 200%T
    -0.3 - 3.0A
    0 - 9999C
    Photometric Accuracy
    Better than 0.3% at 0.5A, 1A, 2A
    Zero Drift < 0.0003A per hour after warm-up
    Baseline Flatness ± 0.001A
    Stability ± 0.0004A/h at 500 nm
    Stray Light < 0.05% at 200 nm and 340 nm
    Scanning Capability Yes
    Physical Characteristics
    Standard Sample Holder
    4-position Cell Holder
    Analogue/Digital Output
    Digital, RS232 Serial, Centronics Parallel
    Dimensions 550(L) x 400(W) x 260(H)
    Weight25 kg
    Shipping Dimensions to be updated
    Shipping Weight to be updated
    Power Requirements
    115V/60Hz or 230V/50Hz, switchable
    Operating Temperature
    Room temperature: 22 ± 2°C
    Humidity Range ≤ 85% relative
    Safety Certificate CE


  • UV-Visible Spectrophotometer
    Spectrophotometer (UV-2900PC )
    All spectrophotometers feature high performance sealed optics mounted on a stable machined platform. All spectrophotometer are intended to be utilized for research, development, quality control, etc. primarily in the fields of optical materials, semiconductors, new materials, electronics and so on through qualitative and quantitative analyses of samples diverse in kind and size. The comprehensive features, optional sophisticated powerful software, variety of accessories and model configurations will meet or exceed your expectations for performance and value.

    The spectrophotometers perform built-in wavelength calibration program automatically after energization. Core components will be check during the initialization to ensure the wavelength accuracy and excellent performance

    Pre-aligned deuterium lamp and tungsten lamp for easy lamp replacement. The light source changing point can be set in range of 300nm - 400nm

    The innovative optical layout ensures accuracy. Its integrated design assures long-term stability and durability. The precisely aligned detector and quality deuterium and halogen lamps enhance the precision.
    Perform basic mode( Abs / %T), quantitative
    Pre-set wavelength program (4 wavelengths), and one-touch key response
    Single-point curve calibration and multi-point curve calibration (up to 12 points)
    Display of fitting degree of curve fitting and concentration data with up to 50 sets of curve parameters storage
    Display of concentration data with up to 200 sets of data storage
    Dark current calibration / wavelength calibration/System clock management
    Backup battery and integrated circuit design controlled by MCU assure non-volatile memory storage
    USB data communication
    LPT port for printing
    128*64 LCD screen to display all of the parameters
    Sealed and solvent-resistant tactile keypad

    Basic Mode

    Multi-Wavelength
    Absorbance, %T or Concentration measurements.
    Up to 15 wavelengths can be selected and multiple samples can be measured. (Auto cell changer is required to run multiple samples automatically).
    Quantitative (Standard Curve)
    Use up to 12 standards to establish standard curve.
    Four methods for fitting a curve:
    a. Linear fit
    b. Linear through zero
    c. Square fit
    d. Segmented

    Wavelength Scanning
    Interval: 0.1, 0.2, 0.5, 1, 2, 5 nm
    Automatically record peaks and valleys.
    Post-run manipulation and processing includes:
    a. Re-scaling axes, curve
    b. Smoothing, combination, zooming, overlap
    c. 1st to 3rd derivative

    Kinetics (Abs vs. Time)

    The Kinetics mode may be used for time course scanning or reaction rate calculations. Abs. vs. time graphs is displayed on the screen in real time. Wait time, measurement time and time intervals may be entered. Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor.

    DNA/Protein
    Concentration and DNA purity can be calculated quickly and easily: Absorbance ratios 230nm/260nm/280nm with optional subtracted absorbance at 320nm.
    Model
    UV-2900PC
    Monochromator
    C-T type, 1200 L/mm grating
    Detector
    Silicon detector for ultraviolet visible region
    Display
    128*64 LCD, Blue color
    Light source

    Deuterium discharge tube(2000h), Tungsten lamp(2000h, 20W/12V)
    Lamp change point
    Can be set, 300 nm - 400 nm
    Wavelength range
    190-1100 nm, autoscan
    Wavelength accuracy
    ±1.0 nm
    Wavelength calibration
    Automatic at start
    Wavelength display
    0.1 nm
    Slit width
    2 nm
    Wavelength repeatability
    0.5 nm
    Measurement range
    -1.0 ~ 200.0%T, -0.5 ~ 3.000Abs, 0 ~ 9999 C, 0 ~ 9999 F
    Photometric accuracy
    ±0.002 Abs (0 to 0.5Abs)
    Photometric repeatability
    ±0.001 Abs (0 to 0.5Abs)
    Stray light
    0.15 %T (at 220,360 nm)
    Baseline flatness
    ≤±0.004 Abs
    Stability
    ≤0.002 Abs / h (at 500 nm, after 2 hours energization)
    Data output
    Digital, USB port, LPT parallel
    Spectrum software
    Spectrum software, Windows® - based
    Power
    220V 10% 50Hz 70VA
    Standard sample holder
    4-position sample holder
    Actual dimensions
    456 W X 375 D X 220 H mm, (18.0 W x 14.8 D x 8.7 H in)
    Net weight
    14.5 Kg (32.0 lbs)
    Shipping dimensions
    19.5 Kg (43.0 lbs)


  • Autoclave (YXQ-LS-75G)
    PRODUCT CHARACTERISTIC:
    Auto-control type with drying function
    Structure of handwheel type quick-door-open safety interlock device (accord with the 49th requirement of Vessel Regulations)
    Material: outer and chamber are made of high quality stainless steel SUS304, acidproof, alkali resistance, anti-corrosive
    Microcomputer intelligent control
    Pressure safety interlock device, over temperature protection device
    Auto-raising type packing ring,exhaust cold air automatically
    Auto-exhause when over pressure, low water level alarm, auto-control when lack of water
    Temperature range (109-135), sterilization time range (4-120min), drying time range (drying after sterilization) (30-240min)
    Inner circulation exhaust type, with 3L steam collection bottle
    Automatic inlet, heating, sterilization, exhaust and drying
    Buzzer reminds after work and close-down automatically
     
    Work process of sterilization and drying
    a: sterilization temperature decreases to 102, then exhaust and drain
    b: sterilization, exhaust and drain after sterilization
    c: sterilization, exhaust, drain, drying
     
    Technical Parameters:
    Model: YXQ-LS-75G
    Volume: 75L
    Max. working temperature: 135
    Max. working pressure: 0.22MPa
    Power Consumption of sterilization: 3.2KW
    Power Consumption of drying: 0.8KW
    Power supply: 220V10%/50Hz2%
    DIM. Exterior (mm): 600*500*1150
    DIM. Interior (mm): 350*625
    DIM. Basket (mm): 360*280*2


Select to
Page 1 of 5 << Previous 1
Go to Page