ECG machine direct from China - Shenzhen Jumper Meditech Co., Ltd
Home» products»ECG machine

Shenzhen Jumper Meditech Co., Ltd

Select to
Page 1 of 1
  • ECG machine

    Features:
    1. Light in weight, compact in size
    2. Three kinds of operation mode: Automatic, Manual, Analysis
    3. Standard lead mode or European lead mode available
    4. Detection and alarm of lead-off, No paper or no battery
    Built-in ECG simulator
    6. Automatic adjustment of baseline for optional recording
    7. RS 232 communication interface for linking to special network or setting up of ECG database
    8. Optional blue tooth interface
    9. Automatic measurement, optional interpretation function in Class G machine
    10. Display of ECG waveform on LCD (Available in Class C and G machine)
    11. Bulit-in help function: Electrode positioning, ECG basic knowledge, dispose of common breakdown etc. (Available in Class G machine)
    12. Clinical information such as patient ID, name, sex, age, height, weight, drugs and hospital name can be input( Available in Class G machine)
    13. Case storage function: 15cases can be saved in the machine or as much as 150cases in a SD card. Saved ECG waveforms can be cine-looped, printed out or transferred to PC. (Available in Class G machine)

    Specification

    Safety standard: IEC class I, type CF
    Acquisition Mode: 12lead acquisition simultaneously
    Input Circuit: Floating, protection against defibrillator and pacemaker
    A/D converter: 18bit
    Frequency response: 0.05-150HZ
    Sensitivity: 2.5, 5, 10, 20mm/mv, auto
    Input impedance:≥50MΩ

  • ECG machine

    ECG-JPD-1103B
    Features:
    1. Light in weight, compact in size
    2. Three kinds of operation mode: Automatic, Manual, Analysis
    3. Standard lead mode or European lead mode available
    4. Detection and alarm of lead-off, No paper or no battery
    5. Built-in ECG simulator, Built-in rechargeable lithium battery with high capacity
    6. Automatic adjustment of baseline for optional recording
    7. RS 232 communication interface for linking to special network, PC, or setting up of ECG detabase, option blue-tooth interface
    8. Bulit-in help function: Electrode positioning, ECG basic knowledge, common trouble-shooting, etc.( not available in Class B machine)
    9. Clinical information such as patient ID, name, sex, age, height, weight, drugs and hospital name can be input( Available in Class G machine)
    10. Case storage function: 15cases can be saved in the machine or as much as 150cases in a SD card. Saved ECG waveforms can be cine-looped, printed out or transferred to PC. (not available in Class B machine)

    Specification:

    Safety standard: IEC class I, type CF
    Acquisition Mode: 12lead acquisition simultaneously
    Input Circuit: Floating, protection against defibrillator and pacemaker
    A/D converter: 18bit
    Time constant: ≥3.2/s
    Frequency response: 0.05-150HZ
    Sensitivity: 2.5, 5, 10, 20mm/mv, auto
    Input impedance :≥50MΩ
    Input circuit current: ≤50nA
    Calibration voltage: 1mV±2%
    Noise level: <15μVp-p
    Filter:
    EMG filter: 35Hz-45Hz (-3dB)
    ADS filter: Auto (0.15-0.5Hz)
    HUM filter: 50Hz/60Hz (-20dB)
    CMRR: >100dB ( with AC filter)
    Patient current leakage: <10μA
    Paper speed: 6.25/12.5/ 25/ 50mm/s
    Recording paper: 50MM (width), 20m/30m (length), roll/Z-fold
    Power requirement:
    AC220V, 50HZ/110V,
    60HZ; 85v-265v (option)
    DC: 12v Bulit-in rechargeable lithium bettery
    Dimension: 345mm*300mm*80mm; 400mm*180mm*355mm (Carton)
    Net weight: 2.5kg; Gross weight: 4.5kg

  • ECG machine

    ECG machine-JPD-1103G
    Features:
    1. Light in weight, compact in size
    2. Three kinds of operation mode: Automatic, Manual, Analysis
    3. Standard lead mode or European lead mode available
    4. Detection and alarm of lead-off, No paper or no battery
    5. Built-in ECG simulator, Built-in rechargeable lithium battery with high capacity
    6. Automatic adjustment of baseline for optional recording
    7. RS 232 communication interface for linking to special network, PC, or setting up of ECG detabase, option blue-tooth interface
    8. Bulit-in help function: Electrode positioning, ECG basic knowledge, common trouble-shooting, etc.( not available in Class B machine)
    9. Clinical information such as patient ID, name, sex, age, height, weight, drugs and hospital name can be input( Available in Class G machine)
    10. Case storage function: 15cases can be saved in the machine or as much as 150cases in a SD card. Saved ECG waveforms can be cine-looped, printed out or transferred to PC. (not available in Class B machine)

    Specification:

    Safety standard: IEC class I, type CF
    Acquisition Mode: 12lead acquisition simultaneously
    Input Circuit: Floating, protection against defibrillator and pacemaker
    A/D converter: 18bit
    Time constant: ≥3.2/s
    Frequency response: 0.05-150HZ
    Sensitivity: 2.5, 5, 10, 20mm/mv, auto
    Input impedance :≥50MΩ
    Input circuit current: ≤50nA
    Calibration voltage: 1mV±2%
    Noise level: <15μVp-p
    Filter:
    EMG filter: 35Hz-45Hz (-3dB)
    ADS filter: Auto (0.15-0.5Hz)
    HUM filter: 50Hz/60Hz (-20dB)
    CMRR: >100dB ( with AC filter)
    Patient current leakage: <10μA
    Paper speed: 6.25/12.5/ 25/ 50mm/s
    Recording paper: 50MM (width), 20m/30m (length), roll/Z-fold
    Power requirement:
    AC220V, 50HZ/110V,
    60HZ; 85v-265v (option)
    DC: 12v Bulit-in rechargeable lithium bettery
    Dimension: 345mm*300mm*80mm; 400mm*180mm*355mm (Carton)
    Net weight: 2.5kg; Gross weight: 4.5kg

     

  • ECG machine

    Features:
    1. Light in weight, compact in size
    2. Three kinds of operation mode: Automatic, Manual, Analysis
    3. Standard lead mode or European lead mode available
    4. Detection and alarm of lead-off, No paper or no battery
    5. Built-in ECG simulator, Built-in rechargeable lithium battery with high capacity
    6. Automatic adjustment of baseline for optional recording
    7. RS 232 communication interface for linking to special network, PC, or setting up of ECG detabase, option blue-tooth interface
    8. Bulit-in help function: Electrode positioning, ECG basic knowledge, common trouble-shooting, etc.( not available in Class B machine)
    9. Clinical information such as patient ID, name, sex, age, height, weight, drugs and hospital name can be input( Available in Class G machine)
    10. Case storage function: 15cases can be saved in the machine or as much as 150cases in a SD card. Saved ECG waveforms can be cine-looped, printed out or transferred to PC. (not available in Class B machine)

    Specification:

    Safety standard: IEC class I, type CF
    Acquisition Mode: 12lead acquisition simultaneously
    Input Circuit: Floating, protection against defibrillator and pacemaker
    A/D converter: 18bit
    Time constant: ≥3.2/s
    Frequency response: 0.05-150HZ
    Sensitivity: 2.5, 5, 10, 20mm/mv, auto
    Input impedance :≥50MΩ
    Input circuit current: ≤50nA
    Calibration voltage: 1mV±2%
    Noise level: <15μVp-p
    Filter:
    EMG filter: 35Hz-45Hz (-3dB)
    ADS filter: Auto (0.15-0.5Hz)
    HUM filter: 50Hz/60Hz (-20dB)
    CMRR: >100dB ( with AC filter)
    Patient current leakage: <10μA
    Paper speed: 6.25/12.5/ 25/ 50mm/s
    Recording paper: 50MM (width), 20m/30m (length), roll/Z-fold
    Power requirement:
    AC220V, 50HZ/110V,
    60HZ; 85v-265v (option)
    DC: 12v Bulit-in rechargeable lithium bettery
    Dimension: 345mm*300mm*80mm; 400mm*180mm*355mm (Carton)
    Net weight: 2.5kg; Gross weight: 4.5kg

  • ECG machine

    Features:
    1. Light in weight, compact in size
    2. Three kinds of operation mode: Automatic, Manual, Analysis
    3. Standard lead mode or European lead mode available
    4. Automatic measurement and interpretation
    5. Detection and alarm of lead-off, No paper or no battery
    6. Built-in ECG simulator, Built-in rechargeable lithium battery with high capacity
    7. Automatic adjustment of baseline for optional recording
    8. RS 232 communication interface for linking to special network, PC, or setting up of ECG database, option blue-tooth interface
    9. Bulit-in help function: Electrode positioning, ECG basic knowledge, common trouble-shooting, etc.
    10. Clinical information such as patient ID, name, sex, age, height, weight, drugs and hospital name can be input( Available in Class G machine)
    11. Case storage function: 15cases can be saved in the machine or as much as 150cases in a SD card. Saved ECG waveforms can be cine-looped, printed out or transferred to PC.

    Specification:

    Safety standard: IEC class I, type CF
    Acquisition Mode: 12lead acquisition simultaneously
    Input Circuit: Floating, protection against defibrillator and pacemaker
    A/D converter: 24bit
    Time constant: ≥3.2/s
    Frequency response: 0.05-165HZ
    Sensitivity: 2.5, 5, 10, 20mm/mv, auto
    Input impedance:≥50MΩ
    Input circuit current: ≤50nA
    Calibration voltage: 1mV±2%
    Noise level: <15μVp-p
    Filter: EMG filter: 35Hz-45Hz (-3dB)
    ADS filter: Auto (0.15-0.5Hz)
    HUM filter: 50Hz/60Hz (-20dB)
    CMRR: >100dB
    Patient current leakage: <10μA
    Paper speed: 6.25/12.5/ 25/ 50mm/s
    Recording paper: 112MM (width), 20m/30m(length), roll/Z-fold
    Power requirement:
    AC220V, 50HZ/110V,60HZ;
    85v-265v (option)
    DC: 14.4v/2Ah
    Bulit-in rechargeable lithium battery
    Dimension: 345mm*300mm*80mm; 400mm*180mm*355mm (Carton)
    Net weight: 2.5kg; Gross weight: 4.5kg

  • ECG machine

    Features:
    1. Simultaneous aciquisition of 12-lead ECG data, real-time recording and printing of 12-channel ECG waveform
    2. Graphic display of 12-lead ECG waveform
    3. Built-in analysis software of age which assurate analysis result
    4. Auto-measurement, auto-interpretation, waveform playback and storage of ECG data
    5. RS 232 and USB interface cope with data-share or remote data management requirement
    6. Option wireless function makes more convenient communication with PC.
    7. User friendly operation system contributed by built-in help function
    8. Literal and graphic operation interface
    9. Powerful filter to minimize interference
    10. Heart rate measurement and pace-maker protection circuit
    11. Multi-printing formats: Manual/automatic, standard 12channel, 3 channel plus 3 rhythm lead, 6 channel, 6 channel plus rhythm lead, 60s anaysis of arrhythmia, R-R histogram, trend graph
    12. AC, DC or built-in lithium battery power supply, alarm of battery weak and lead-off
    13. Comfort and durability contributed by silicon gel keypad
    14. Tremendous ECG data can be saved in built-in SD card

    Specification:

    Screen size: Class L 5.7 inch; Class M 7.0 inches
    Input Circuit: Floating, protection against defibrillator and pacemaker
    Lead: Standard 12 lead
    A/D converter: 12bit
    Time constant: >3.2/s
    Frequency response: 0.05-165HZ (-3dB)
    Measurement: Heart rate, PR Int., Vent. Rate, P/QPS/T Axis
    Sensitivity: 2.5, 5, 10, 20mm/mv (±2%), auto
    Input impedance:≥50MΩ
    Input circuit current: ≤50nA
    Calibration voltage: 1mV±2%
    Noise level: <15μVp-p
    Patient data: Date, time, ID, name, gender, age, height, weight, blood pressure, etc
    CMRR: >100dB
    System Data: Sensitivity, paper speed, filter on/off, hospital name, etc
    Paper speed: 6.25/12.5/ 25/ 50mm/s (±3%)
    Print-out: waveform, waveform+measurement report, or waveform+measurement report+anaysis report
    Power requirement:
    AC100V, 50HZ/240V,
    60HZ; 85v-265v (option)
    DC: 19v/3.5A; Battery: 14.4v/4400mAh bulit-in rechargeable lithium battery, over 2hours working time
    Dimension: 345mm*300mm*80mm; 400mm*180mm*355mm (Carton)
    Net weight: 3.5kg; Gross weight: 5.5kg
    Carton size: 216mm*30m roll paper, or 216mm*100mm*200pages Z-fold paper

Select to
Page 1 of 1 << Previous 1 Next>>
Go to Page