Patient Monitor

Model No: CMS9000

Description

Description:
    Features

 1.Color TFT Screen, waveform  up to 8 channels

 2.Light and portable with build-in rechargeable battery

 3.UP to 10 kinds of monitor parameters

 4.Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis 2

 5.72 hour storage and review of trend grams and tables, 40 second review of olographic wavefo rms.

 6.Built-in recorder(option)

 7.All-round monitor of adult ,pediatric and neonatal.

 8.Electrosurgical unit and defibrillation protected

 9.Standard parameters: ECG, NIBP, SPO2,  Respiration,  Temperature, Pulse rate

 10.Option parameters: EtCO2, CO,  IBP,  thermal   printer                                           

 ECG

 5-lead or 3-lead selectable

 Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C

 Lead selection: I; II; III; avR; avL; avF; Vx; CAL

 Gain selection: 12.5mm/s, 25mm/s, 50mm/s

 Accuracy: ±1bpm or ±1%, whichever is greater

 Protection: Withstand 4000VAC/50Hz voltage in  isolation against electrosurgical and defibrillation

 Calibration signal: 1mV3%

 Operation modes: Diagnostic, Monitor, Surgery

 Alarm range: Adult: 15-300bpm

 Pediatric/Neonatal: 15-350bpm

 Alarm range: -2.0mV~2.0mV

 S-T detection: YES, Arrhythmia analysis: YES

 Alarm: YES, audible and visual alarm, alarm events recallable

 NIBP

 Method: Oscillometry

 Operation modes: Manual/Automatic/STAT

 Measurement unit: mmHg/KPa selectable

 Measurement types: Systolic, Diastolic, Mean

 Measurement range: Adult: 10-270mmHg

 Over-pressure protection: YES

 Resolution: 1mmHg

 Accuracy: Mean error and standard deviation   per ANSI/AAMI SP-10

 Alarm: Systolic,Diastolic,Mean

 SpO2

 Measurement range: 0-100%

 Accuracy: 70~100%; 0~69% unspecified

 Alarm range: 0-100%

 Respiration

 Method: RA-LL impedance

 Pediatric/Neonatal: 6-150rpm

 Alarm range: Adult: 6-120rpm

 Pediatric/Neonatal: 6-150rpm

 Apnea alarm: YES

 Temperature

 Resolution: 0.1

 Channel: Dual-channel

 Alarm range: 0-50

 Option:

 EtCO2

 Measurement Mode: Side-stream or mainstream

 Measurement range: EtCO2: 0-99mmHg

 Accuracy: CO2 concentration

 Apnea alarm: YES

 CO

 Method: Thermo-dilution

 Measurement range: CO: 0.1-20 lit./min.

 IBP

Channel: 2 channels

 Pressure transducer: Sensitivity: 5( mV/V/mmHg)

 Transducer sites: ART, PA, CVP, RAP, LAP, ICP

 Alarm range: -10~300mmHg


Other Information
Location: China
Category: Surgical Equipment>>Defibrillator
Contact Preference:
FOB Range:
Minimum order Quantity:  
KeyWords : Patient Monitor,Defibrillator