Product catalog - Changsha Epower Electronics & Science, CO.,LTD
Home » Products »

Changsha Epower Electronics & Science, CO.,LTD

Product
Select to
Page 9 of 9
  • Micro Syringe Pump CE Mark & ISO Certification

    XB-1101 syringe pump is a kind of intellectualized automatic infusion device which is designed for delivery of vein by a constant flow rate. The product can be applied to clinical application of intravenous Injection. It is characterized by precision of dosage rate, sufficient function and simple operation.

    Functions and Features:
    (1) Operation modes: Flow rate controlled infusion mode, volume and time controlled infusion mode.
    A) flow rate controlled infusion mode: There are seven flow rate units of available such as ml/h, mg/h, ug/h, mg/kg/h, mg/kg/min, ug/kg/h, ug/kg/min.
    B) Volume and Time Controlled Infusion mode: It enables the users to control the infusion by setting the desired volume and the desired time to be infused, it will be the assistance to the traditional manual injection.
    (2) Bolus function: Help patients to past the stimulative phase safely and steadily.
    (3) KVO function: Automatically start the KVO(keep the vein open) infusion when the normal infusion stopped.
    (4) Non-volatile memory: The pump memories all the setup parameters and history data of the last infusion.
    (5) Alarm and Warns: When something abnormal occurs, the pump can give out alarming and warning information such as AC power failure, battery low, near empty of the syringe, empty of the syringe /occlusion, end of infusion, Syringe disengaged etc.
    (6) Available syringe: All kinds of syringe whose standard capacity is in the standard capacity set 10ml, 20ml, 50(60)ml can be used in the pump by custom syringe's setting. And the infusion accuracy can be guaranteed.SPECIFICATIONS:
    Range of Flow rate: 10ml syringe: 0.1~300ml/h;
    20ml syringe: 0.1~400ml/h;
    50(60)ml syringe: 0.1~600ml/h;
    Accuracy: +/-3% (on condition that the total infusion capacity is more than 5.0ml and the infusion rate is more than 2.0ml/h and the syringe extension set have been purged)
    Bolus rate: 300ml/h
    Display: A large screen (128*64 pixel), rotary setting with convenient operation interface.
    Operating conditions:
    Ambient temperature: +5~+40C
    Relative humidity (RH): 30 %~75 %
    Power supply:
    AC: 100V~245V\50 +/-1Hz
    Battery: 14.4V battery can use for more than 3 hours after charged for 10 hours.
    Atmospheric pressure: 860~1060hPa
    Dimension (mm): 336(L)*153(W)*132(H)
    Weight: 2.5kg
    Safety Classification: Class II and Type C


  • Syringe pump

    Introduction:
    XB-800 Syringe Pump syringe pump is routine use equipment for hospital emergent treatment, cure and nursing. It adopts the new technology of microcomputer with compact structure. It has multi-intelligent alarm functions, could use disposable syringe of many kinds of, strong functions and use convenient. It is especially suitable for exact micro infusion or quick infusion for long time. This product is use for push the syringe to control the liquid amount into patient body for medical institution.
    1. Work Condition
    1.1 Ambient temperature: +5c---- 40c
    1.2 Relative humidity: 20%~90%
    1.3 Power supply: AC220V 22V, 50Hz
    1.4 Built-in batteries: 12V, 1.2h/A (Undervoltage value ≤ 10.5V)
    It can be used for 2 hours continuously after 24 hours full charged.
    1.5 Atmospheric Pressure: 860hpa~1060hpa
    1.6 Storage Temperature: -40c~+55c
    2. Basic Parameters
    2.1 Dimensions (mm): 320 (L)/145(W)/120(H)
    2.2 Weight: Approximately 3 kg
    2.3 Power Consumption: ≤19.8VA
    2.4 Compatible Syringe Size: 10ml, 20ml, 30ml, 50ml Disposable
    2.5 Infusion Flow Selection: 0.1~199.9ml/h, original value is 0.1ml/h
    2.6 Infusion Range: 0.1~999.9ml, original value is 0.1ml
    2.7 Occlusion Pressure: 40K~70K pa
    2.8 Flow Rate Precision: 5%(0.1ml/h≤Flow Rate≤50ml/h)
    /3%(50ml/h≤Flow Rate≤199.9ml/h)
    2.9 Alarm: Self-Test, Occlusion, Nearly Finish, Finish, Low battery,
    Standby, Move
    2.10 Functions: Syringe's Type Test, Transfusion amount display, Flow rate display, Power display, Auto-Alarm, KVO function

    After power off, the electrical memory function keeps for five years
    (Only effective for setting content)


  • Vet Infusion Pump

    Vet infusion pumps, vet syringe pumps, vet anaesthesia pump, syringes, infusion sets and so on vet use medical equipments; Human use infusion pump, human use syringe pump and so on medical equipments in China, our head office is located in Hunan province, China, and has branches in Shenzhen and Changsha, have our own R&D dept. And sales teams, we welcome OEM, ODM and custom-tailor according to your actual requirements.

    XB-900 Vet Infusion Pump
    CHARACTERISTICS:
    1>2 control ways: Can be used in either drop counting control way or volumetric control way ml/h or drops/min
    2>High speed: 1ml/h~1000ml/h or 1 drop/min ~250 drop/min.
    3>3 levels of occlusion value: High, middle and low.
    4>Hard based free-flow protection: Avoid any free flow or leakage, prevent any danger to patients.
    5>Drops detector: Can detect the drops infused, automatically detect the IV line type and ensure the accuracy for any IV line.
    6>Applicable IV Sets: Any standard IV sets.
    7>Rechargeable internal battery.
    8>Visible and audible alarm: When any malfunction, error, air-on-line, occlusion, error flow rate and so on.
    9>KVO function: After infusion is complete, the pump automatically switches to the smallest flow to prevent creating the thrombus.
    10>Bolus function: When during infusion, press a key to infuse at the rate of 400ml/h.


  • Volumetric Infusion Pump

    XB-1101 syringe pump is a kind of intellectualized automatic infusion device which is designed for delivery of vein by a constant flow rate. The product can be applied to clinical application of intravenous Injection. It is characterized by precision of dosage rate, sufficient function and simple operation.

    Functions and Features:
    (1) Operation modes: Flow rate controlled infusion mode, volume and time controlled infusion mode.
    A) flow rate controlled infusion mode: There are seven flow rate units of available such as ml/h, mg/h, ug/h, mg/kg/h, mg/kg/min, ug/kg/h, ug/kg/min.
    B) Volume and Time Controlled Infusion mode: It enables the users to control the infusion by setting the desired volume and the desired time to be infused, it will be the assistance to the traditional manual injection.
    (2) Bolus function: Help patients to past the stimulative phase safely and steadily.
    (3) KVO function: Automatically start the KVO(keep the vein open) infusion when the normal infusion stopped.
    (4) Non-volatile memory: The pump memories all the setup parameters and history data of the last infusion.
    (5) Alarm and Warns: When something abnormal occurs, the pump can give out alarming and warning information such as AC power failure, battery low, near empty of the syringe, empty of the syringe /occlusion, end of infusion, Syringe disengaged etc.
    (6) Available syringe: All kinds of syringe whose standard capacity is in the standard capacity set 10ml, 20ml, 50(60)ml can be used in the pump by custom syringe's setting. And the infusion accuracy can be guaranteed.


    Infusion pump & syringe pump top manufacturer, welcome to contact Ms Sunny for further.

    1> Flow rate: 1ml/h~1000ml/h or 1 drops/min ~250 drops/min.
    2> 2 work modes: Liquid volume mode and drops mode, ml/h or drops/min.
    3> 3 levels of occlusion value: Adjustable from high, meddle and low.
    4> Free-flow protection: Prevent any free flow or leakage.
    5> Reasonable and unique structure and design prevent bringing any air bubble and air bubble alarm error.
    6> Drop detector: Automatically demarcate the accuracy of any IV set, accordingly improve the infusion accuracy.
    7> Can use any standard of IV set, automatically remember this IV line type.
    8> Rechargable battery.
    9> Visible and audible alarms for any malfunction, air-on-line, operation error, unnormal flow rate and so on.