  • Fetal Monitor
    12.1 Large-screen Color TFT Display
    Light Weight and Portable, Easy Operation Mode
    Maximum 11 Hours Storage and Replay of Monitoring Data
    Built-in High-capacity Battery, Up to 7 Hours Working Time
    Advanced Digital Signal Processing (DSP) Technique is Applied for Real-time Calculation and Mode Identification;
    High-sensitive Probe, Excellent Signal/Noise Rate and Calculation Accuracy Enable to Monitor Fetus More Safely
    Intellectualized Voice/Light Alarms Accurately Transmit Diseases
    Built-in Recorder, Able to Print or Store Waveforms and Monitoring Status at Real Time
    Network Capability, Compatible with Obstetric Central Monitoring System
    Standard Configuration
    FHR
    TOCO
    FM
    Battery

    Optional Configuration
    Build-in Printer
    Twin

    Technical Parameters
    TOCO
    Range: 0-100 Pressure Units
    Nonlinear Tolerance for Measurement: ± 5%

    FHR
    Probe: 9 Chips, Wide Wave Packet, Pulse Wave
    Strength of Ultrasonic Wave: ≤ 3mW Cm2
    Working Frequency: 1.0MHz or 2.2MHz
    Signal Processing: Special Digital Signal Processing (DSP) and Mode Identification
    Range: 10-240bpm

    FM Counting Method
    Manual

    Printer (Optional)
    Type: Built-in 50mm Thermal Printer
    Port: Standard Parallel

    Safety Specification
    In Compliance with IEC60601 and GB9706 Related Standards

    Weight: 5.5kg

    Dimension: 320mm(W)x280mm(H)x170mm(D)
    Power Requirement
    Voltage: AC100-240V 50HZ/60HZ

    Standard Accessories: 1 x Three -in -One Probe (FHR, TOCO, FM), 1 x Biding Belt, 1 x Caster Oil, 1 x Ground Line

    Optional Accessories: Build-in Recorder

  • ECG machine
    CM1200 twelve-channel ECG, with 12.1 inch color TFT 12 leads acquisition simultaneously. Touch screen and hiding handle, easy for movement. RJ45 and RS-232 interface for data transmission to PC. USB interface for patient records transmission
    Features:
    Automatic adjustment of baseline. Optional selections for Rhythm lead.
    12.1 inch high-resolution color folding up touch-screen
    AC/DC power supply built-in rechargeable li-ion battery
    Single button operation
    Sleep/wake up mode for saving energy and extending LCD life
    Freeze real time waveform and record with selected format
    Last 120 seconds waveforms reviewable and recordable
    Printing preview of waveforms and auto-diagnosis result
    Various printing formats
    Complete digital filter, avoid baseline drift, AC. EMG interference
    Automaticlly detect and record arrhythmia
    Internal storage for up to 200 digital ECG records
    Support all the ECG rolling paper, folded paper



  • ECG machine
    Single Color TFT Display (Resolution 320x240), Thermal Recorder (80mmx20m)
    Simultaneously 12 Leads Acquisition, Optional Selections for Rhythm Lead.
    Use Special High-definition digital wave filter to eliminate AC and ECG interference
    Accurate Indication for Unstable Probe Touch
    High Resolution Thermal Printer, Synchronous Record Details of ECG Waveforms, Leads.
    Automatic Measurement of ECG Parameters with English Waveforms Analysis Report, Various Printout Format
    Safety Design, Completely ECG Amplifier Grounding, Enhance the Safety of Patients
    Built-in Li-ion Battery, Perfectly Battery Management and Protection Capacity,
    Support Uninterrupted Working Up to 2 hours
    60 Exams Patient Data Storage

    Working Condition

    Environment: 5~40º C
    Relative Humidity: 25%~80%
    Air Pressure: 860hpa~1060hpa
    Voltage: AC110V/220V
    Frequence: 50/60Hz
    Index Parameter Index Parameter
    Lead Standard 12 Lead Rhythm Lead Standard 12 lead
    Input Circuit Isolated, Protection against pace packing and defibrillation Operation Mode Auto/Manual
    Input Impedence ≥ 1 0M Ω Frequency Response 0.05-150Hz(-3dB)
    Input Circuit Current ≤50nA Recording Speed 5,10, 25 ,50mm /s
    Gain 5 ,10, 20 mm/mv Recording Paper Roll Paper: 80mmX 20m
    Filter AC: 50/60Hz—20dB
    EMG: 35/45Hz—3dB Sampling Rate 1kHz ,12 lead
    Skin Voltage Tolerance ±350mV A/D Converter 12bit
    CMRR ≥90dB Display 320×240 English Menu Display
    Calibrating 1mV±2% Analyse Function Output analysis
    Time Constant 3.2s(0,+20%) External Input 10mm /V±5%;single endedv≥100kΩ
    Noise Level ≤15uVp-P ECG Output 1V/mV±5%; signle ended ≤100Ω
    Baseline Control Automatic position Safty Level Clasee 1, TypeCF
    Recording System Thermal array printer Case Memory 150 exams


  • ECG machine
    Automatic measurement of ECG waveform
    Fully automatic waveform analysis report output
    Complete digital design, single color LCD display
    Simultaneously 12 leads acquisition, optional selections for rhythm lead
    Automatic adjustment of baseline, amplification and automatic lead switch
    Digital wave filter to eliminate baseline drift, AC and EMG interference
    60 electrocardiograms record and recall,
    Built-in rechargeable Li-ion battery, support 2 hours uninterrupted operation
    AC/DC power supply, automatic protection circuit
    Thermal recorder, Various Printout Format
    Accurate lead off detection and display
    Network Capability
    Working Condition
    Environment: 5~40º C
    Relative Humidity: 25%~80%
    Air Pressure: 860hpa~1060hpa
    Voltage: AC110V/220V
    Frequence: 50/60Hz
    Index Parameter Index Parameter
    Lead Standard 12 Lead Rhythm Lead Standard 12 lead
    Input Circuit Isolated, Protection against pace packing and defibrillation Operation Mode Auto/Manual
    Input Impedence ≥ 1 0M Ω Frequency Response 0.05-150Hz(-3dB)
    Input Circuit Current ≤50nA Recording Speed 5,10, 25 ,50mm /s
    Gain 5 ,10, 20 mm/mv Recording Paper Roll Paper: 50mmX 20m
    Filter AC: 50/60Hz—20dB
    EMG: 35/45Hz—3dB Sampling Rate 1kHz ,12 lead
    Skin Voltage Tolerance ±350mV A/D Converter 12bit
    CMRR ≥90dB Display 192×64 English Menu Display
    Calibrating 1mV±2% Analyse Function Output analysis
    Time Constant 3.2s(0,+20%) External Input 10mm /V±5%;single endedv≥100kΩ
    Noise Level ≤15uVp-P ECG Output 1V/mV±5%; signle ended ≤100Ω
    Baseline Control Automatic position Safty Level Clasee 1, TypeCF
    Recording System Thermal array printer Case Memory 60 exams

  • ECG machine
    Automatic measurement of ECG waveform
    Fully automatic waveform analysis report output
    Complete digital design, single color LCD display
    Simultaneously 12 leads acquisition, optional selections for rhythm lead
    Automatic adjustment of baseline, amplification and automatic lead switch
    Digital wave filter to eliminate baseline drift, AC and EMG interference
    60 electrocardiograms record and recall,
    Built-in rechargeable Li-ion battery, support 2 hours uninterrupted operation
    AC/DC power supply, automatic protection circuit
    Thermal recorder, Various Printout Format
    Accurate lead off detection and display
    Network Capability
    Working Condition
    Environment: 5~40º C
    Relative Humidity: 25%~80%
    Air Pressure: 860hpa~1060hpa
    Voltage: AC110V/220V
    Frequence: 50/60Hz
    Index Parameter Index Parameter
    Lead Standard 12 Lead Rhythm Lead Standard 12 lead
    Input Circuit Isolated, Protection against pace packing and defibrillation Operation Mode Auto/Manual
    Input Impedence ≥ 1 0M Ω Frequency Response 0.05-150Hz(-3dB)
    Input Circuit Current ≤50nA Recording Speed 5,10, 25 ,50mm /s
    Gain 5 ,10, 20 mm/mv Recording Paper Roll Paper: 50mmX 20m
    Filter AC: 50/60Hz—20dB
    EMG: 35/45Hz—3dB Sampling Rate 1kHz ,12 lead
    Skin Voltage Tolerance ±350mV A/D Converter 12bit
    CMRR ≥90dB Display 192×64 English Menu Display
    Calibrating 1mV±2% Analyse Function Output analysis
    Time Constant 3.2s(0,+20%) External Input 10mm /V±5%;single endedv≥100kΩ
    Noise Level ≤15uVp-P ECG Output 1V/mV±5%; signle ended ≤100Ω
    Baseline Control Automatic position Safty Level Clasee 1, TypeCF
    Recording System Thermal array printer Case Memory 120 exams

  • Patient Monitor
    8.4 Large-screen Color TFT Display
    Light Weight and Portable, Easy Operation Mode
    AC/DC Power Supply, Uninterrupted Monitoring
    Built-in High-capacity Battery, Up to 5 Hours Working Time
    6-Lead ECG Waveforms Display Interface
    Big Fonts Observational Interface
    Reviewable ECG waveforms, S-T Segment Analysis
    Maximum 128 Hours Graphic and Tabular Trends
    3-Hour of HR, SpO2, and RESP Graphic Trends Directly Show on the Main Interface
    Digital SpO2 Technique, Precise Measurement for Low Perfusion and Finger Shaking
    Intellectualized Voice/Light Alarms Accurately Transmit Diseases
    Adult/Pediatric/Neonatal measurement modes
    2 Windows Display, Net-working Capability

    Standard Configuration

    ECG/HR SpO2 NIBP RESP TEMP Pulse
    --------------------------------------------------------------------------------
    Optional Configuration

    IBP
    EtCO2
    Nellcor SpO2
    Inner Printer
    Special Accessories for Neonatal and Pediatric Patient

    Technical Parameters

    ECG
    Lead Number: 5
    Lead Selection: I, II, III, avR, avL, avF, V1-V6
    Gain Selection: X0.5, x1, x2, x4
    Scan Speed: 12.5mm/s, 25mm/s, 50mm/s
    HR Range: 30-250bpm
    Accuracy: ± 1bpm

    NIBP
    Measurement Technique: Automatic Oscillometric
    Measurement Range:
    Adult: 30-240mmHg
    Accuracy: ± 5 mmHg
    Resolution: ± 1 mmHg
    Measure Mode: Manual /Automatic
    Automatic Measuring Interval: 3-240min

    Temperature
    Range: 20º C-45º C
    Accuracy: ± 0.1; C
    Resolution: 0.1; C

    Pulse
    Range: 20-250bpm
    Accuracy: ± 1bpm
    Resolution: 1bpm

    SpO2
    Range: 70-100%
    Resolution: ± 1%
    Accuracy: ± 1%

    Respiration
    Range: 0-60bpm
    Accuracy: 1bpm
    Resolution: 1bpm

    Graphic and Tabular Trends
    Parameters Display: HR, SpO2, Respiration, Systolic Pressure, Average Pressure, Diastolic Pressure, Pulse Rate

    Features: 96 Hours Storing of Trend Graph, Capable of Tracing and Showing Parameter Data of Any Selected Point by Using a Staff Guage

    Alarm
    Range: Adjustable from Lower to Upper Limit
    Cause: Irregular Indication
    Indication: Audible and Visual Dual Indication

    Printer (Optional)
    Type: 50mm Thermal Printer
    Port: Standard Parallel

    Safety
    In Compliance with IEC60601 and GB9706 Related Standards

    Net Weight
    4kg

    Dimension
    320mm(W)x280mm(H)x170mm(D)

    Power Requirement
    Voltage: AC100-240V 50HZ/60HZ



Select to
Page 1 of 2 << Previous 1