Autoclaves|China Steam Autoclaves|Autoclaves Sterilizer Manufacturers,Suppliers&Exporters
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.
Select to
Page 8 of 15
  • Vacuum steam autoclaves
     vacuum steam autoclaves is small type one which according to Class B stardard. It can sterilize the solid, hollow, without package,single/double appliance,etc. which the big type do it.
    It is very popular in dental clinique, internal medicine, E.N.T.department and laboratory etc.

    Company: CVS Digital CO.,LTD
  • PORTABLE PRESSURE STEAM STERILIZER
    Characteristics

    With pressure steam adjuster, when pressure reached the setting value ,it will keep and control.

    With timer ,when the time reached the setting ,auto turn off power and alarm to tell sterilize end.
    Withsafety valve, release valve and gauge ;,when the steam pressure go over0.165Mpa,the release valve should exhaust the pressure to ensure thesafety ,there is reading on the gauge face for both MPA and temperaturefor check in date.

    With electric heating element of immerge type ,pressure control and water lack protection.
    Thecontainer and drum adopted stainless steel 0GR18Ni9Ti ,anti-acid,anti-alkali and anti-rust .And main mechanism capability trebleupwards than aluminum alloy , so it will be insure the safety  capability and service life.

    Company: Shenzhen Kaguwi Imp & Exp Co., Ltd.
  • Autoclave (YXQ-LS-75G)
    PRODUCT CHARACTERISTIC:
    Auto-control type with drying function
    Structure of handwheel type quick-door-open safety interlock device (accord with the 49th requirement of Vessel Regulations)
    Material: outer and chamber are made of high quality stainless steel SUS304, acidproof, alkali resistance, anti-corrosive
    Microcomputer intelligent control
    Pressure safety interlock device, over temperature protection device
    Auto-raising type packing ring,exhaust cold air automatically
    Auto-exhause when over pressure, low water level alarm, auto-control when lack of water
    Temperature range (109-135), sterilization time range (4-120min), drying time range (drying after sterilization) (30-240min)
    Inner circulation exhaust type, with 3L steam collection bottle
    Automatic inlet, heating, sterilization, exhaust and drying
    Buzzer reminds after work and close-down automatically
     
    Work process of sterilization and drying
    a: sterilization temperature decreases to 102, then exhaust and drain
    b: sterilization, exhaust and drain after sterilization
    c: sterilization, exhaust, drain, drying
     
    Technical Parameters:
    Model: YXQ-LS-75G
    Volume: 75L
    Max. working temperature: 135
    Max. working pressure: 0.22MPa
    Power Consumption of sterilization: 3.2KW
    Power Consumption of drying: 0.8KW
    Power supply: 220V10%/50Hz2%
    DIM. Exterior (mm): 600*500*1150
    DIM. Interior (mm): 350*625
    DIM. Basket (mm): 360*280*2


    Company: Tsingtao Unicom-Optics Instruments Co., Ltd.
  • Autoclave
    1. This disinfection device has two designs: the ordinary design and the auto design (both designs are stainless).
    2. It is well sealed and effectively prevents steam leakage.
    3. The manometers on the machine directly show the working pressure and temperature enabling the user to monitor the disinfection course.
    4. With a safe valve, safety is guaranteed.
    5. The auto design is equipped with Germany imported water device timely reflects the water level in the tank and is more reliable and safer.
    6. The auto design automatically adjusts the pressure.
    7. The auto design automatically handles the disinfection time.

    Technical parameters

    maximun working pressure     0.175Mpa
    maximun working temperature     130℃
    volume of disifection charm     18L
    Power     2KW/AC 220V 50Hz
    Factory price(USD)     galvanothermy and coal     133.00
    galvanothermy     151.00

    Company: Jiaxing zhongxin Medical instruments Co.,Ltd
  • Pulse-vacuum Autoclave
    pulsation vacuum Autoclave/Sterilizer
    Application: clothes, dressing, instruments, vessel in pharmacy industry with saturated steam.
    Quality system: GMP Standard, ISO 9001-2000 and ISO 13485 quality system, China relative standards.
    Safety system: Overpressure protection, Door safety interlock system, Overloading and short circuit protection.
    Structure: Horizontal cylinder chamber, made of SS 304,finely ponished, covered by insolation material;
    Door: Level-sliding door, automatic door or hand-operated door.
    GMP Validation joint.
    Control System: PLC, touch screen, Printer. Temperature, pressure, F0 and other datas can be recorded or stored at any time.
    Pipeline System: Pneumatic valve,Vacuum pump, etc.
    Technical Parameters (Automatic Door Series)
    Specification
    YXQ.MG-202
    YXQ.MG-203
    YXQ.MG-206
    YXQ.MG-208
    YXQ.MG-210
    YXQ.MG-215
    YXQ.MG-220
    YXQ.MG-225
    Volume(m3)
    0.25
    0.36
    0.6
    0.8
    1.2
    1.5
    2.0
    2.5
    Inner size
    L×W×H mm
    1000×500×500
    1020×550×650
    1240×650×750
    1020×750×1050
    1530×750×1050
    1910×750×1050
    1700×1000×1200
    1670×100
    0×1500
    Outer size
    L×W×Hmm
    1280×1250×1800(S)
    1290×1250×1800(S)
    1520×1350×1800(S)
    1275×1450×1900(S)
    1785×1450×1900(S)
    2165×1450×1900(S)
    2060×2000×2000(S)
    2160×200
    0×2200(S)
    1340×1250×1800(D)
    1360×1250×1800( D)
    1580×1350×1800(D)
    1360×1450×1900( D)
    1870×1450×1900( D)
    2250×1450×1900( D)
    2100×2000×2000(D)
    2200×200
    0×2200( D)
    Steam
    0.4-0.8Mpa
    15kg
    20kg
    30kg
    40kg
    50kg
    60kg
    70kg
    80kg
    Washing water
    0.15-0.3Mpa
    40kg
    45kg
    50kg
    55kg
    60kg
    65kg
    70kg
    75kg
    Compressed air(m3)
    0.5-0.8
    0.5-0.8
    0.5-0.8
    0.5-0.8
    0.5-0.8
    0.5-0.8
    0.5-0.8
    0.5-0.8
    Power
    (kw)
    3
    3
    3
    3
    3
    3
    4.5
    4.5
    Net weight(kg)
    700
    1200
    1500
    1700
    2100
    2500
    3000
    3500
    Design pressure(Mpa)0.245
    Design Temperature(oC)141

    Company: ZHANGJIAGANG HUALING MEDICAL EQUIPMENT MANUFACTURING CO., LTD
  • Horizontal Cylindrical Pressure Steam Sterilizer (WS-150YDA)

    Horizontal cylindrical pressure steam sterilizer
    WS-280YDA WS-200YDA WS-150YDA

    Characteristics:
    1. The steam can't go through to chamber when the door haven't close, and the pilot off inform. You can processing dry operat.
    2. When the pressure inner over 0, 027MPa. The door be locked and can't be open.
    3. If you not choose the sterile time and star the machine, buzzer sound.
    4. If you mistake open the door in the course of start, the jacker value auto off and open the chamber value.
    5. Lack water the pilot on, heating and sterile pilot off, the buzzer sound and auto release steam.
    6. Overload and leakage protection, when leakage or over current occur, it auto off the piwer.
    7. Temperature controlled not work and the inner pressure over 0.165MPa, the safety value auto star open.

    Technical Data:
    Model technical data: WS-280YDA, WS-200YDA, WS-150YDA
    Sterilizing chamber volume: 280L(φ600 x 1000mm), 200L(φ515 x 1000mm), 150L(φ440 x 1000mm)
    Working pressure: 0.22 MPa
    Working temperature: 134 Celsius degree
    Adjustment of temperature: 40 - 134 Celsius degree
    Time of sterilization: 0-60 min
    Time of drying: 0-60 min
    Heat average: ≤ +2 Celsius degree or -2 Celsius degree
    Power: 12KW/380V 50Hz, 9KW/380V 50Hz, 9KW/380V 50Hz
    N/G: 340 / 440 KG, 290 / 380 KG, 270 / 360 KG


    Company: China Shikang Medical Equipment Group Limited
  • Horizontal Cylindrical Pressure Steam Sterilizer (WS-150YDA)

    Horizontal cylindrical pressure steam sterilizer
    WS-280YDA WS-200YDA WS-150YDA

    Characteristics:
    1. The steam can't go through to chamber when the door haven't close, and the pilot off inform. You can processing dry operat.
    2. When the pressure inner over 0, 027MPa. The door be locked and can't be open.
    3. If you not choose the sterile time and star the machine, buzzer sound.
    4. If you mistake open the door in the course of start, the jacker value auto off and open the chamber value.
    5. Lack water the pilot on, heating and sterile pilot off, the buzzer sound and auto release steam.
    6. Overload and leakage protection, when leakage or over current occur, it auto off the piwer.
    7. Temperature controlled not work and the inner pressure over 0.165MPa, the safety value auto star open.

    Technical Data:
    Model technical data: WS-280YDA, WS-200YDA, WS-150YDA
    Sterilizing chamber volume: 280L(φ600 x 1000mm), 200L(φ515 x 1000mm), 150L(φ440 x 1000mm)
    Working pressure: 0.22 MPa
    Working temperature: 134 Celsius degree
    Adjustment of temperature: 40 - 134 Celsius degree
    Time of sterilization: 0-60 min
    Time of drying: 0-60 min
    Heat average: ≤ +2 Celsius degree or -2 Celsius degree
    Power: 12KW/380V 50Hz, 9KW/380V 50Hz, 9KW/380V 50Hz
    N/G: 340 / 440 KG, 290 / 380 KG, 270 / 360 KG


    Company: China Shikang Medical Equipment Group Limited
  • LS-B75L-I Vertical pressure steam sterilizer(fully automatic autoclave)

    LS-B75L-I VERTICAL PRESSURE 
    STEAM STERILIZER

    (AUTOMATIC  AUTOCLAVE)

    Characteristics:

     

    l .Whole body inner and outer by stainless steel

    2.Hand wheel type of quick-open door structure

    3.Door safety lock system

    4.Digital display of working status,touch of key

    5.Auto-letting off the cool air,and steam discharging

    automatically after sterilization

    6.Over temperature&over pressure auto-protection

    7.Safe protection of water lacking

    8.Self-inflating type seal

    9.Automatically shut off with beep reminding after sterilization

    10.With two stainless steel sterilizing baskets

    11.With dry cycle

     


    Company: China Shikang Medical Equipment Group Limited
  • LS-B75L-I Vertical pressure steam sterilizer(fully automatic autoclave)

    LS-B75L-I VERTICAL PRESSURE 
    STEAM STERILIZER

    (AUTOMATIC  AUTOCLAVE)

    Characteristics:

     

    l .Whole body inner and outer by stainless steel

    2.Hand wheel type of quick-open door structure

    3.Door safety lock system

    4.Digital display of working status,touch of key

    5.Auto-letting off the cool air,and steam discharging

    automatically after sterilization

    6.Over temperature&over pressure auto-protection

    7.Safe protection of water lacking

    8.Self-inflating type seal

    9.Automatically shut off with beep reminding after sterilization

    10.With two stainless steel sterilizing baskets

    11.With dry cycle

     


    Company: China Shikang Medical Equipment Group Limited
  • Horizontal Cylindrical Pressure Steam Sterilizer (WS-150YDB)
     Horizontal cylindrical pressure steam sterilizer
    WS-280YDB  WS-200YDB  WS-150YDB
    Characteristics:
     
    1.Sterilizing course automatic sterilization controlled by computer, easy to operate.
    2.With drying function, suitable dressing drying.
    3.With over-temperature, over-pressure auto-protect device.
    4.The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can’t be start on if the doesn’t closed well.
    5.The safety value will be open automatically when the inner pressure over 0.24MPa, and the steam be exhausting to the water tank.
    6.The power will be cut-off automatically, cut-off the water and alarm when the machine lacking water.
     



    Company: China Shikang Medical Equipment Group Limited
Select to
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.
Page 8 of 15    ...... 8 ......
Go to Page