ECG Machine| China ECG Machine| ECG Machine Products Manufacturers
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.
Select to
Page 7 of 23
  • ECG machine

    Features:
    1. Simultaneous aciquisition of 12-lead ECG data, real-time recording and printing of 12-channel ECG waveform
    2. Graphic display of 12-lead ECG waveform
    3. Built-in analysis software of age which assurate analysis result
    4. Auto-measurement, auto-interpretation, waveform playback and storage of ECG data
    5. RS 232 and USB interface cope with data-share or remote data management requirement
    6. Option wireless function makes more convenient communication with PC.
    7. User friendly operation system contributed by built-in help function
    8. Literal and graphic operation interface
    9. Powerful filter to minimize interference
    10. Heart rate measurement and pace-maker protection circuit
    11. Multi-printing formats: Manual/automatic, standard 12channel, 3 channel plus 3 rhythm lead, 6 channel, 6 channel plus rhythm lead, 60s anaysis of arrhythmia, R-R histogram, trend graph
    12. AC, DC or built-in lithium battery power supply, alarm of battery weak and lead-off
    13. Comfort and durability contributed by silicon gel keypad
    14. Tremendous ECG data can be saved in built-in SD card

    Specification:

    Screen size: Class L 5.7 inch; Class M 7.0 inches
    Input Circuit: Floating, protection against defibrillator and pacemaker
    Lead: Standard 12 lead
    A/D converter: 12bit
    Time constant: >3.2/s
    Frequency response: 0.05-165HZ (-3dB)
    Measurement: Heart rate, PR Int., Vent. Rate, P/QPS/T Axis
    Sensitivity: 2.5, 5, 10, 20mm/mv (±2%), auto
    Input impedance:≥50MΩ
    Input circuit current: ≤50nA
    Calibration voltage: 1mV±2%
    Noise level: <15μVp-p
    Patient data: Date, time, ID, name, gender, age, height, weight, blood pressure, etc
    CMRR: >100dB
    System Data: Sensitivity, paper speed, filter on/off, hospital name, etc
    Paper speed: 6.25/12.5/ 25/ 50mm/s (±3%)
    Print-out: waveform, waveform+measurement report, or waveform+measurement report+anaysis report
    Power requirement:
    AC100V, 50HZ/240V,
    60HZ; 85v-265v (option)
    DC: 19v/3.5A; Battery: 14.4v/4400mAh bulit-in rechargeable lithium battery, over 2hours working time
    Dimension: 345mm*300mm*80mm; 400mm*180mm*355mm (Carton)
    Net weight: 3.5kg; Gross weight: 5.5kg
    Carton size: 216mm*30m roll paper, or 216mm*100mm*200pages Z-fold paper


    Company: Shenzhen Jumper Meditech Co., Ltd
  • Wireless Stress Test System
    Specification:
    Sample rate: 1000Hz
    Resolution: 12 bit
    Filter: 35 Hz, 50/60Hz
    Gain: 5, 10, 20mm/mV
    Heart rate range: 30-300bpm
    Frequency response: 0.05-150Hz
    Input impedance: ≥50 MΩ
    Dynamic input range: ±3mV
    Anti-polarization voltage: ±500mV
    Communication: wireless transmission, USB
    Wireless transmitter power supply: 5.0V (DC)
    Wireless receiver power supply: 3.0 (DC)
    Transmitter dimension: 92 x 63 x 28 mm
    Receiver dimension: 149 x 79 x 21 mm



    Company: Beijing Risingmed Medcal CO.,LTD
  • Digital 1-channel Handheld Electrocardiograph
    Features:
    Hand-held single channel digital ECG machine with measurement report
    Automatic and manual operation modes
    LCD display ECG wave
    AC/DC power, built-in rechargeable Ni-MH battery
    Mini size, hand-held, portable, convenient for doctors’use anywhere



    Company: Beijing Risingmed Medcal CO.,LTD
  • Digital 12-channel Electrocardiograph
    Features:
    8.4’’ TFT screen with high resolution
    standard 12-lead ECG waveform
    Easy and convenient to operate
    Large LCD screen for easy observation of various lead waveforms.
    Automatic analysis : based on arrhythmia leads
    Automatic printing
    Patients’ name, age, ID, weight input etc.
    It is manually editable, which makes the analysis result more accurate.
    Recording methods: automatic lead recording, manual recording, automatic recording, arrhythmia analysis recording (optional), data statistics, single key swift recording and selection recording.
    Build-in chargeable battery, able to continue operating the device when there is no AC power supply temporarily.
    21cm printer can record 12-lead ECG waveform simultaneously. And the rolling paper is easy to replace.
    The device is smart and flexible to use and carry, especially suitable for hospitals, first-aid centers, sickrooms and collectivity check.



    Company: Beijing Risingmed Medcal CO.,LTD
  • Handheld Single Channel ECG (CE certified)

    Technical Parameters
    Input circuit: Floating
    Calibrating Voltage: 1mV ±5 %
    Input current :< 100nA
    CMRR :> 103dB
    A/D: 12bit
    Frequency Response: 0.05Hz--150Hz
    Filter: AC 50/60Hz EMG: 35-4Hz
    Skin Voltage Tolerance:±300mV
    Sensitivity Setting:5 、10 、20mm/mV, conversion deviation25%
    Noisy Level:≤15μVp-p
    Safety standard: IEC class I, type CF
    Lead selection: Automatic and Manual
    Operation mode: Automatic and Manual
    Display: LCD 160*96 visual size: 34*60
    Recording system: Thermal-array printing
    Power supply: AC220V±10% DC 7.4 lithium battery
    Size: 190*90*40
    Weight: 800g


    Company: Contec medical
  • Digital Twelve Channel ECG

    Technical parameter of ECG-1200A Digital Twelve Channel ECG
    Model:ECG-1200
    Specification
    1.Input Circuit : Floating; Protection against Defibrillator effect
    2.Lead: Standard 12 leads ,Lead change automatically
    3.Patient Current Leakage:<10 &mu A
    4.Input Impedance:>=50 M &Omega
    5.Calibrating Voltage: 1mV (+.-)3%
    6.A/D Conversion:12 bit
    7.Display:320*240LCD
    8.Frequency Response:0.05Hz-150Hz
    9.Time Constant:>3.2seconds
    10.CMRR:>80d>100dB(with filter)
    11.Paper Speed:25,50mm/s(+.-)3%
    12.Recording Paper: 210mm*30m, high-speed roll
    13.Input Circuit Current: <=50nA
    14.Safety Standard: IEC class I, type CF
    15.Sensitivity: 1/2,1,2(cm/mV)
    16.Skin Voltage Tolerance: (+.-)300mV
    17.Noise Level:<15 &muVp-p
    18.Weight of ECG: 5.1kg

    Major Products and Services:Pulse oximeter, fetal doppler, patient monitor, ECG, EEG, ultrasound, EMG, other medical equipment


    Company: Contec medical
  • Digital Single Channel ECG

    Features:
    High-resolution thermal printing array system
    Frequency response is as high as 150Hz
    Capable of printing continuously on channel trace and annotations including lead mark and parameter such as sensitivity, paper speed and filter operation status
    High resolution digital filter inhibits baseline drift without affecting ECG waveform
    One-touch operation
    Concept of floating input circuit meets IEC safety standard
    Rechargeable battery supporting more than 50 patient examinations
    Lead Standard: 12 leads


    Company: Contec medical
  • 12-channel Holter system LCD display

    Analyzing software Features
    1.Multi-windows operation
    2.46 different types Arrhythmia analysis
    3.DEMIX morphologies
    4.Check sinus node recovery time
    5.Check parasystole
    6.Check accelerate escape rhythm
    7.Check reciprocal beat
    8.T wave alterans
    9.Heart rate variability
    10.HRT (Heart rate turbulence)
    11.Sleep Apnea analysis
    12.Intellectual analysis of various tachycardia
    13.Display start and end point of arrhythmia on same screen
    14.Beat to beat analysis, no missing beats
    15.26 types Histogram analysis
    16.Pacemaker analysis can label 7 types shapes
    17.ST-T analysis

    Recorder Features
    *1.77 inch color LCD, displays three leads ECG for each screen
    *High resolution make it is convenient to observe P or Q wave and other micro-signal.LCD screen display ECG grid to facilitate physician to watch ECG waves, count HR and other parameter
    *Skin resistance measurement can evaluate the connection between electrode and patient skin
    *Can freeze the ECG strip in the screen to observe it in detail
    *Battery estimate in case of non-record by low power
    *Holter information browser to display the start time and duration of current recording
    *Speed:25mm/s, gain:5mm/mV for LCD screen display
    *No operation within two minutes, the screen will be auto-off to save power.And button can be locked automatically in case of misoperation
    *Event button can make mark for symptom
    *The cable socket is mis-plug and break-off proof design.

    Recorder specification
    A) Holter Recorder Power:DC 3.0V;
    B) Recording time:24 Hours;
    C) Recording mode:Continuous;
    D) Sample rate:4000Hz;
    E) Standard sensitivity:10mm/mV (-5%, +5%);
    F) Input circuit current:≤0.1μA;
    G) Input impedance:>=2.5 M?;
    H) Noise electric level:<=15μVp-p;
    I) Frequency response:0.05 -150 Hz;
    J) CMRR:≥60 dB;
    K) Lower frequency feature:Time constant is not
    Less than 3.2s;
    L) Equipment safety type:The Holter Recorder is Type-BF with internal power;


    Company: Jinco Medical Equipment Co., Ltd
  • 3-channel Holter system without LCD display

    Analyzing software Features
    1. Multi-windows operation
    2. 46 different types Arrhythmia analysis
    3. DEMIX morphologies
    4. Check sinus node recovery time
    5. Check parasystole
    6. Check accelerate escape rhythm
    7. Check reciprocal beat
    8. T wave alterans
    9. Heart rate variability
    10. HRT (Heart rate turbulence)
    11. Sleep Apnea analysis
    12. Intellectual analysis of various tachycardia
    13. Display start and end point of arrhythmia on same screen
    14. Beat to beat analysis, no missing beats
    15. 26 types Histogram analysis
    16. Pacemaker analysis can label 7 types shapes
    17. ST-T analysis

    Recorder Features
    *. Can support 5 leads and 7 leads system;
    *. High sample rate ensure better quality, non-distortion ECG waves;
    *. One AA alkaline battery for 24 hours recording;
    *. Event button can make mark for symptom;
    *. The cable socket is mis-plug and break-off proof design;
    *. USB 2.0 interface, less time for playback;
    *. Flash memory chipset, which can be re-written more than hundred thousand
    *. Times, provide reliable performance;

    Recorder specification
    A) Holter Recorder Power: DC 1.5V;
    B) Recording time: 24 Hours;
    C) Recording mode: Continuous;
    D) Sample rate: 4000Hz;
    E) Standard sensitivity: 10mm/mV (-5%, +5%);
    F) Input circuit current: &le;0.1μA;
    G) Input impedance: >=2.5 M? ;
    H) Noise electric level: <=15μVp-p;
    I) Frequency response: 0.05 -150 Hz;
    J) CMRR: &ge;60 dB;
    K) Lower frequency feature: Time constant is not Less than 3.2s;
    L) Equipment safety type: The Holter Recorder is type-BF with internal power;


    Company: Jinco Medical Equipment Co., Ltd
  • PC-ECG

    Functions: 12 leads simultaneous ECG, Vector-cardiograph (VCG), Timed Vector-cardiograph (TVCG), Heart Rate Variability (HRV), Signal Averaged Electrocardiography (SAECG/VLP), QT Dispersion (QTD) and High Frequency ECG (HFECG)

    1) High accuracy of auto interpretation.
    2) Unique children ECG auto analysis according different age and weight.
    3) Customer defined ECG, user can sample V7, V8, V9 and 3R, V4R, V5R.
    4) High quality QRS complex. QRS amplitude is not affected by filter.
    5) High quality ECG cable, clips and suckers. The electrode is plating AG/AgCl and the electric conductivity is better than plating Ni.

    6) Electromagnetic isolation and 4000V isolation ensure patient safety.
    7) Support both Wilson lead system and Frank lead system
    8) Electron ruler function.
    9) Multi type report output.
    10) Auto adjustment of lead space, different lead will not be overlapped.

    11) Can save more than 800 thousands cases depending on hard disk memory.
    12) Multi combination search conditions.
    13)2 years warranty period. Minimum charges for services after warranty period

    Specifications of wired ECG acquisition box
    1) Sample rate: >=500Hz;
    2) Sample resolution: 12bit;
    3) Voltage: DC 5.0V (+5%, -10%)
    4) Lead: 12-lead standard ECG;
    5) Leads display mode: Simultaneous 12-Lead
    6) Input circuit current: <=0.1uA;
    7) Input impedance: >=5 M(Ohms);
    8) Standard sensitivity: 10mm/mV 5%;
    9) CMRR: >=80 dB;
    10) Anti-polarization voltage: If add +300mV DC polarization voltage, the change of sensitivity is not more than 5%;
    11) Frequency response: 1 -75 Hz (+0.4 dB, -3.0 dB), as the benchmark is 10Hz;
    12) Lower frequency feature: Time constant is not less than 3.2s;
    13) 50Hz filter: >=20dB;
    14) Noise electric level: <=15uVp-p;
    15) Min test signal: 10Hz, 20UV sine signal;
    16) Interference between leads: In the situation of multi-leads display and printing, the waves deflection aroused by interference between leads should less than 0.5mm;
    17) Equipment safety type: The wired ECG acquisition box is class II, type-BF;
    18) Working environment: Temperature: 5 - 30, Relative humidity: <=80%, Atmospheric pressure: 860 - 1060hPa;


    Company: Jinco Medical Equipment Co., Ltd
Select to
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.
Page 7 of 23    7 ......
Go to Page