  • volume pump manufacturer
    Application:
    1. critical care of Human,infant ,pediatrics
    3. Nursing use
    2. For veterinary use

    CHARACTERISTICS

    * Compatible with IV sets of any brand with high accuracy.

    * Automatically calibration for IV sets of any brand.

    * Three working modes: Rate control and Time control mode,Volumetric mode.

    * 8 Hours internal battery life in high capacity.

    * Have a unique color LCD and an internal battery with a high capability.

    *Switch between ml/h and drops/min freely.

    *Three levels of alarm volume: high, medium and low.

    *Three levels of occlusion pressure: high, medium and low.

    *KVO function: After infusion is complete, the pump automatically switches to the smallest flow to prevent the thrombus.

    syringe pump back

    SPECIFICATIONS

    SPECIFICATIONS
    Controls:
    Drop counting and adjusting the delivery rate automatically
    Pump Type: Peristaltic finger
    Applicable IV Sets:
    Compatible with IV sets of any standard (including lucifugal IV sets) 20d/ml or 60d/ml.
    Accuracy:
    ≤25drop/min:±2%, >25drop/min:±3% (With the drop counting control mode)
    ±5% (With the rate control mode after the correct calibration)
    Delivery Rate Range:
    1∼400drop/min(1drop/min step)
    1.0ml/h∼1200ml/h (1.0ml/h∼99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step)
     Delivery Time Range: 1min∼1999min (1 min step)
    Volume Limit Range: 0∼9999ml (1 ml step)
     Total Volume Range: 1∼9999ml (1 ml step)

     Rapid injection: 600ml/h 
    infusion pump2KVO Rate:

    W hen the delivery rate≤10ml/h, KVO is  1 ml/h .   Otherwise KVO is 3ml/h.
    Alarms:
    Air-in-line, Infusion complete when limited volume has been set, Empty container, Occlusion, Door is open, waitting time Over, No drop been detected, Operational errors, Low battery, other device failures.
    Power Supply:
    AC power supply: AC 100 to 240V±10%,50/60Hz
    Internal LI Battery: 11.1V, 2000mAh. 8 Hours of continous operation on a new fully charged battery with the rate of 20 drops/min.
    Power Consumption: ≤25VA
    Safety level: Class, Type BF
    Dimensions: 130mm(L)× 200mm(W) × 230mm(H)
    Net Weight: Approximately. 2.5kg
    Operating Conditions: Ambient temperature: 5 to 40Relative humidity: 20 to 90%
    Storage Conditions: Ambient temperature: -10 to 55Relative humidity: 10 to 90%
    Accessories: AC power line, Operational manual

    Company: Jian Yuan Medical Technology Co.,Ltd.
  • infusion pump
    Application:
    1. critical care of Human,infant ,pediatrics
    3. Nursing use
    2. For veterinary use

    CHARACTERISTICS

    * Compatible with IV sets of any brand with high accuracy.

    * Automatically calibration for IV sets of any brand.

    * Three working modes: Rate control and Time control mode,Volumetric mode.

    * 8 Hours internal battery life in high capacity.

    * Have a unique color LCD and an internal battery with a high capability.

    *Switch between ml/h and drops/min freely.

    *Three levels of alarm volume: high, medium and low.

    *Three levels of occlusion pressure: high, medium and low.

    *KVO function: After infusion is complete, the pump automatically switches to the smallest flow to prevent the thrombus.

    syringe pump back

    SPECIFICATIONS

    SPECIFICATIONS
    Controls:
    Drop counting and adjusting the delivery rate automatically
    Pump Type: Peristaltic finger
    Applicable IV Sets:
    Compatible with IV sets of any standard (including lucifugal IV sets) 20d/ml or 60d/ml.
    Accuracy:
    ≤25drop/min:±2%, >25drop/min:±3% (With the drop counting control mode)
    ±5% (With the rate control mode after the correct calibration)
    Delivery Rate Range:
    1∼400drop/min(1drop/min step)
    1.0ml/h∼1200ml/h (1.0ml/h∼99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step)
     Delivery Time Range: 1min∼1999min (1 min step)
    Volume Limit Range: 0∼9999ml (1 ml step)
     Total Volume Range: 1∼9999ml (1 ml step)

     Rapid injection: 600ml/h 
    infusion pump2KVO Rate:

    W hen the delivery rate≤10ml/h, KVO is  1 ml/h .   Otherwise KVO is 3ml/h.
    Alarms:
    Air-in-line, Infusion complete when limited volume has been set, Empty container, Occlusion, Door is open, waitting time Over, No drop been detected, Operational errors, Low battery, other device failures.
    Power Supply:
    AC power supply: AC 100 to 240V±10%,50/60Hz
    Internal LI Battery: 11.1V, 2000mAh. 8 Hours of continous operation on a new fully charged battery with the rate of 20 drops/min.
    Power Consumption: ≤25VA
    Safety level: Class, Type BF
    Dimensions: 130mm(L)× 200mm(W) × 230mm(H)
    Net Weight: Approximately. 2.5kg
    Operating Conditions: Ambient temperature: 5 to 40Relative humidity: 20 to 90%
    Storage Conditions: Ambient temperature: -10 to 55Relative humidity: 10 to 90%
    Accessories: AC power line, Operational manual

    Company: Jian Yuan Medical Technology Co.,Ltd.
  • peristaltic pump

    Application:
    1. critical care of Human,infant ,pediatrics
    3. Nursing use
    2. For veterinary use

    CHARACTERISTICS

    * Compatible with IV sets of any brand with high accuracy.

    * Automatically calibration for IV sets of any brand.

    * Three working modes: Rate control and Time control mode,Volumetric mode.

    * 8 Hours internal battery life in high capacity.

    * Have a unique color LCD and an internal battery with a high capability.

    *Switch between ml/h and drops/min freely.

    *Three levels of alarm volume: high, medium and low.

    *Three levels of occlusion pressure: high, medium and low.

    *KVO function: After infusion is complete, the pump automatically switches to the smallest flow to prevent the thrombus.

    syringe pump back

    SPECIFICATIONS

    SPECIFICATIONS
    Controls:
    Drop counting and adjusting the delivery rate automatically
    Pump Type: Peristaltic finger
    Applicable IV Sets:
    Compatible with IV sets of any standard (including lucifugal IV sets) 20d/ml or 60d/ml.
    Accuracy:
    ≤25drop/min:±2%, >25drop/min:±3% (With the drop counting control mode)
    ±5% (With the rate control mode after the correct calibration)
    Delivery Rate Range:
    1∼400drop/min(1drop/min step)
    1.0ml/h∼1200ml/h (1.0ml/h∼99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step)
     Delivery Time Range: 1min∼1999min (1 min step)
    Volume Limit Range: 0∼9999ml (1 ml step)
     Total Volume Range: 1∼9999ml (1 ml step)

     Rapid injection: 600ml/h 
    infusion pump2KVO Rate:

    W hen the delivery rate≤10ml/h, KVO is  1 ml/h .   Otherwise KVO is 3ml/h.
    Alarms:
    Air-in-line, Infusion complete when limited volume has been set, Empty container, Occlusion, Door is open, waitting time Over, No drop been detected, Operational errors, Low battery, other device failures.
    Power Supply:
    AC power supply: AC 100 to 240V±10%,50/60Hz
    Internal LI Battery: 11.1V, 2000mAh. 8 Hours of continous operation on a new fully charged battery with the rate of 20 drops/min.
    Power Consumption: ≤25VA
    Safety level: Class, Type BF
    Dimensions: 130mm(L)× 200mm(W) × 230mm(H)
    Net Weight: Approximately. 2.5kg
    Operating Conditions: Ambient temperature: 5 to 40Relative humidity: 20 to 90%
    Storage Conditions: Ambient temperature: -10 to 55Relative humidity: 10 to 90%
    Accessories: AC power line, Operational manual

    Company: Jian Yuan Medical Technology Co.,Ltd.
Select to
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.
Page 6 of 6    6 Next>>
Go to Page