BNT-2000B Infant Radiant Warmer
STANDARD COMPOSITION
●Temperature Control Mode: pre-heating control, servo control & manual control; ● Instant Parameter Display: set temp, skin temp, heat power rate; ● Built-in APGAR Timer and >37℃ preset function ● Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override; ● Tilting Bed with Rotary Radiant Head; ● X-ray Cassette Tray under infant bed, examination light of high illuminance; ● Use anti-blast quartz infrared tube as radiant heating source; ● With phototherapy unit; ● With two oxygen cylinders; ● With Suction, with neonate resuscitation.
STANDARD COMPOSITION:
● Use LED light as lighting source, LED digital timer, display therapy time & total time
TECHNICAL SPECIFICATION:
POWER Model B-400-1E.........................................................................110 / 120 Vac, 50Hz / 60Hz Model B-400-2E................................................................................220 / 240Vac, 50Hz / 60Hz Input power...............................................................................................................≤50VA Accord with IEC 60601-1 standard, this device is in class I, continuous handling. Ebi in effective area surface.....................................................................................500μW/cm2 Ebi max in effective area surface..............................................................................650μW/cm2 Ebi average in effective area surface...................................................................................500μW/cm2 Uniformity of Ebi...............................................................>0.4 Infrared radiation in effective area....................................<1mW/cm2(760nm<λ≤1400nm= Ultraviolet radiation in effective area................<1.0×10-5mW/cm2 (180nm<λ≤400nm= Time display accuracy............................................................................................2h±1min Operate noise........................................≤50dB(A)(ambit noise is lower than 40dB(A)) ENVIRONMENT CONDITION Environment temperature Operate temperature range................................................................................................................+10℃ ~ +30℃ Storage temperature range.......................................................................-40℃ ~ +70℃ Environment humidity Operate humidity range...........................................................................................30%~75% Storage humidity range...................................................................................................≤80% Transport and storage atmospheric pressure range.....................................500hPa~1060hPa
STANDARD COMPOSITION: ●Servo Control Mode: air temp; ● Instant Parameter Displaying: set temp, air temp and heat power rate; ● Audible & Visual Alarms: power failure, sensor failure, higher & lower temp, air temp override,fan failure,system failure; ● >37℃ Preset Mode: power failure reset memory, alarm silence, keypad lock, self-test function; ● Hood with dual slope: 6 hand-ports; left & right cabinets, top-shelf; ● RS-232 Output Connector (Use for network system ).
STANDARD COMPOSITION: ● Servo Control Mode: air temp; ● Instant Parameter Displaying: set temp, air temp, heat power rate; ● Audible & Visual Alarms: power failure, sensor failure, higher/lower temp, air temperature override, fan failure; ● Power failure reset memory and self-test function; ● Hood with dual slope: 4 hand-ports.
STANDARD COMPOSITION ●Servo Control Mode:air temperature ● Instant Parameter Display: set temp, skin temp, heat power rate; ● Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override; ● Tilting Bed with Rotary Radiant Head ● X-ray Cassette Tray under infant bed, examination light of high illuminance; ● Use anti-blast quartz infrared tube as radiant heating source.