  • Infant Radiant Warmer

    BNT-2000B Infant Radiant Warmer

    STANDARD COMPOSITION

    Temperature Control Mode: pre-heating control, servo control & manual control;
    Instant Parameter Display: set temp, skin temp, heat power rate;
    Built-in APGAR Timer and >37 preset function
    Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
    Tilting Bed with Rotary Radiant Head;
    X-ray Cassette Tray under infant bed, examination light of high illuminance;
    Use anti-blast quartz infrared tube as radiant heating source;
    With phototherapy unit;
    With two oxygen cylinders;
    With Suction, with neonate resuscitation.

     

     


    Company: China Shikang Medical Equipment Group Limited
  • Infant Phototherapy Unit
    B-400 Infant Phototherapy Unit

    STANDARD COMPOSITION:


    ● Use LED light as lighting source, LED digital timer, display therapy time & total time

     

     

    TECHNICAL SPECIFICATION:


    POWER
    Model B-400-1E.........................................................................110 / 120 Vac, 50Hz / 60Hz
    Model B-400-2E................................................................................220 / 240Vac, 50Hz / 60Hz
    Input power...............................................................................................................≤50VA
    Accord with IEC 60601-1 standard, this device is in class I, continuous handling.
    Ebi in effective area surface.....................................................................................500μW/cm2
    Ebi max in effective area surface..............................................................................650μW/cm2
    Ebi average in effective area surface...................................................................................500μW/cm2
    Uniformity of Ebi...............................................................>0.4          
    Infrared radiation in effective area....................................<1mW/cm2(760nm<λ≤1400nm=
    Ultraviolet radiation in effective area................<1.0×10-5mW/cm2 (180nm<λ≤400nm=
    Time display accuracy............................................................................................2h±1min
    Operate noise........................................≤50dB(A)(ambit noise is lower than 40dB(A))
    ENVIRONMENT CONDITION
    Environment temperature
    Operate temperature range................................................................................................................+10℃ ~ +30℃
    Storage temperature range.......................................................................-40℃ ~ +70℃
    Environment humidity
    Operate humidity range...........................................................................................30%~75%
    Storage humidity range...................................................................................................≤80%
    Transport and storage atmospheric pressure range.....................................500hPa~1060hPa

     



    Company: China Shikang Medical Equipment Group Limited
  • Infant Phototherapy Unit
    B-400 Infant Phototherapy Unit

    STANDARD COMPOSITION:


    ● Use LED light as lighting source, LED digital timer, display therapy time & total time

     

     

    TECHNICAL SPECIFICATION:


    POWER
    Model B-400-1E.........................................................................110 / 120 Vac, 50Hz / 60Hz
    Model B-400-2E................................................................................220 / 240Vac, 50Hz / 60Hz
    Input power...............................................................................................................≤50VA
    Accord with IEC 60601-1 standard, this device is in class I, continuous handling.
    Ebi in effective area surface.....................................................................................500μW/cm2
    Ebi max in effective area surface..............................................................................650μW/cm2
    Ebi average in effective area surface...................................................................................500μW/cm2
    Uniformity of Ebi...............................................................>0.4          
    Infrared radiation in effective area....................................<1mW/cm2(760nm<λ≤1400nm=
    Ultraviolet radiation in effective area................<1.0×10-5mW/cm2 (180nm<λ≤400nm=
    Time display accuracy............................................................................................2h±1min
    Operate noise........................................≤50dB(A)(ambit noise is lower than 40dB(A))
    ENVIRONMENT CONDITION
    Environment temperature
    Operate temperature range................................................................................................................+10℃ ~ +30℃
    Storage temperature range.......................................................................-40℃ ~ +70℃
    Environment humidity
    Operate humidity range...........................................................................................30%~75%
    Storage humidity range...................................................................................................≤80%
    Transport and storage atmospheric pressure range.....................................500hPa~1060hPa

     



    Company: China Shikang Medical Equipment Group Limited
  • Infant Incubator (B-3000)
    STANDARD COMPOSITION:
    ●Servo Control Mode: air temperature,skin temperature;
    ● Instant Parameter Displaying: set temp, air temp ,skin temp,internal humidity,heat power rate;
    ● Audible & Visual Alarms: power failure, sensor failure, higher & lower temp, air& skin  temp override,fan failure,system failure;
    ● >37℃ Preset Mode: power failure reset memory, alarm silence, keypad lock, self-test function;
    ● Hood with dual slope: 6 hand-ports; left & right cabinets, top-shelf;
    ● RS-232 Output Connector (Use for network system ).

    Company: China Shikang Medical Equipment Group Limited
  • Infant Incubator (B-3000)
    STANDARD COMPOSITION:
    ●Servo Control Mode: air temperature,skin temperature;
    ● Instant Parameter Displaying: set temp, air temp ,skin temp,internal humidity,heat power rate;
    ● Audible & Visual Alarms: power failure, sensor failure, higher & lower temp, air& skin  temp override,fan failure,system failure;
    ● >37℃ Preset Mode: power failure reset memory, alarm silence, keypad lock, self-test function;
    ● Hood with dual slope: 6 hand-ports; left & right cabinets, top-shelf;
    ● RS-232 Output Connector (Use for network system ).

    Company: China Shikang Medical Equipment Group Limited
  • Infant Incubator (B-1000)

    STANDARD COMPOSITION:
    ●Servo Control Mode: air temp;
    ● Instant Parameter Displaying: set temp, air temp and heat power rate;
    ● Audible & Visual Alarms: power failure, sensor failure, higher & lower temp, air temp override,fan failure,system failure;
    ● >37℃ Preset Mode: power failure reset memory, alarm silence, keypad lock, self-test function;
    ● Hood with dual slope: 6 hand-ports; left & right cabinets, top-shelf;
    ● RS-232 Output Connector (Use for network system ).


    Company: China Shikang Medical Equipment Group Limited
  • Infant Incubator (B-1000)

    STANDARD COMPOSITION:
    ●Servo Control Mode: air temp;
    ● Instant Parameter Displaying: set temp, air temp and heat power rate;
    ● Audible & Visual Alarms: power failure, sensor failure, higher & lower temp, air temp override,fan failure,system failure;
    ● >37℃ Preset Mode: power failure reset memory, alarm silence, keypad lock, self-test function;
    ● Hood with dual slope: 6 hand-ports; left & right cabinets, top-shelf;
    ● RS-232 Output Connector (Use for network system ).


    Company: China Shikang Medical Equipment Group Limited
  • Infant Incubator (B-800)

    STANDARD COMPOSITION:
    ● Servo Control Mode: air temp;
    ● Instant Parameter Displaying: set temp, air temp, heat power rate;
    ● Audible & Visual Alarms: power failure, sensor failure, higher/lower temp, air temperature override, fan failure;
    ● Power failure reset memory and self-test function;
    ● Hood with dual slope: 4 hand-ports.


    Company: China Shikang Medical Equipment Group Limited
  • Infant Incubator (B-800)

    STANDARD COMPOSITION:
    ● Servo Control Mode: air temp;
    ● Instant Parameter Displaying: set temp, air temp, heat power rate;
    ● Audible & Visual Alarms: power failure, sensor failure, higher/lower temp, air temperature override, fan failure;
    ● Power failure reset memory and self-test function;
    ● Hood with dual slope: 4 hand-ports.


    Company: China Shikang Medical Equipment Group Limited
  • Infant Radiant Warmer (BNT-1000)

    STANDARD COMPOSITION 
    ●Servo Control Mode:air temperature
    ● Instant Parameter Display: set temp, skin temp, heat power rate;
    ● Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
    ● Tilting Bed with Rotary Radiant Head
    ● X-ray Cassette Tray under infant bed, examination light of high illuminance;
    ● Use anti-blast quartz infrared tube as radiant heating source.