  • TKR-200 High-Frequency Jet Ventilaotr
    A kind of opening high and normal-frequency jet ventilator with pressure regulating and time circle form. Its principle is: under the airway opening state, using high pressure gas power (O2 or compressive air) and high gas flow, rhythmically jet gas into airway through an electronic automatically controlled route, to expand the long for gas exchange.
     
    Feature:
    A. Two ventilation modes: High-Frequency Jet Ventilation (HFJV) and Continuous Positive Airway Pressure (CPAP).
    B. ABS engineering plastic cabinet and good looking PVC panel.
    C. Multiform ventilation modes and alarm function, its convenient operation is suitable for medium or minitype hospital and rural hospital.

    Specifications:
    Frequency: 8
    150 breaths/min
    I/E ratio: 1:1
    1:3 and inverse ratio
    Driving Pressure: 0
    0.30MPa
    CPAP: 0.1
    0.8 KPa
    Maximum Oxygen Concentration: 85%
    Alarm: Alarm with light and sound when no power and it will last more than 120 seconds; or alarm when no oxygen for 6 seconds.
    Humidifying Rate: 015ml/h
    Pressure Regulator Limit: 0.35MPa
    Ventilation Modes: HFJV (High Frequency Jet Ventilation); CPAP (Continuous positive airway pressure),Manual ventilation.


    Company:  Jiangxi TELI Anaesthesia & Respiration Equipment Co., Ltd.
  • TKR-300B High-Frequency Jet Ventilator

    a kind of opening high frequency jet ventilator with pressure regulating and time circle form. Its principle is: under the airway opening state, using high pressure gas power (O2 or compressive air) and high gas flow, rhythmically jet gas into airway through an electronic automatically controlled route, to expand the lung for gas exchange.

    Feature:

    TKR-300B computerized jet ventilator is a normal ventilating device with the best performance and being widely used in clinical among the same grade high-frequency ventilators.
    A. Process ventilation modes controlled by computer, it is good to increase partial pressure of oxygen and decrease the reserve of CO2.
    B. Digital display adjusted by lightly triggering of frequency. The adjustable range of I/E is wide, with reciprocity function.
    C. Multi-funttional humidifier adaptor saits for connection of ISO and national standard is disposed, The humidifier device si conveniently connected to the main frame.

     

    Specifications:

    Frequency:10~150 breaths/min
    I/E ratio: 1:1,1:1.5~1:5 and inverse ratio
    SIGH:6breaths/min, I/E=1:4
    Driving Pressure:0~0.30MPa
    Pressure Regulator Limit:0.35MPa
    Most jetting volume:1400ml/time
    CPAP:≥1.5KPa
    Oxygen Concentration Adjustable:40%-90%
    Pressure Atomizer Rate:≥10ml/h
    Process Ventilation:T=10min,I/E=1:1.5,f(150):f(35)=7:3,infinite cycle
    Depressing frequency:start from 60breathmin, and then depress the frequency one time every 1 minute till down to 10breaths/min
    Alarm:Alarm with light and sound for no power or no gas
    Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure),HFJV+SIGH; Process ventilation frequency decreasing, Manual Control Mode.


    Company:  Jiangxi TELI Anaesthesia & Respiration Equipment Co., Ltd.
  • TKR-300B High-Frequency Jet Ventilator

    a kind of opening high frequency jet ventilator with pressure regulating and time circle form. Its principle is: under the airway opening state, using high pressure gas power (O2 or compressive air) and high gas flow, rhythmically jet gas into airway through an electronic automatically controlled route, to expand the lung for gas exchange.

    Feature:

    TKR-300B computerized jet ventilator is a normal ventilating device with the best performance and being widely used in clinical among the same grade high-frequency ventilators.
    A. Process ventilation modes controlled by computer, it is good to increase partial pressure of oxygen and decrease the reserve of CO2.
    B. Digital display adjusted by lightly triggering of frequency. The adjustable range of I/E is wide, with reciprocity function.
    C. Multi-funttional humidifier adaptor saits for connection of ISO and national standard is disposed, The humidifier device si conveniently connected to the main frame.

     

    Specifications:

    Frequency:10~150 breaths/min
    I/E ratio: 1:1,1:1.5~1:5 and inverse ratio
    SIGH:6breaths/min, I/E=1:4
    Driving Pressure:0~0.30MPa
    Pressure Regulator Limit:0.35MPa
    Most jetting volume:1400ml/time
    CPAP:≥1.5KPa
    Oxygen Concentration Adjustable:40%-90%
    Pressure Atomizer Rate:≥10ml/h
    Process Ventilation:T=10min,I/E=1:1.5,f(150):f(35)=7:3,infinite cycle
    Depressing frequency:start from 60breathmin, and then depress the frequency one time every 1 minute till down to 10breaths/min
    Alarm:Alarm with light and sound for no power or no gas
    Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure),HFJV+SIGH; Process ventilation frequency decreasing, Manual Control Mode.


    Company:  Jiangxi TELI Anaesthesia & Respiration Equipment Co., Ltd.
  • TKR-300CG High-Frequency Jet Ventilator
    can ventilate with high frequency and is widely used for narcosis, respiration, medicine, surgery and peditarics to auxiliarily feed oxygen on ventilation management, ventilation treatment and first –aid anabiosis.
    Feature: 
    A. The device adopts impulse jet oxygen feeding technique with great flow rate of oxygen feeding in a shot while, when feeding oxygen, it adopts change mode major in reflux and many kinds of gas flow mechanism such as convection, laminar flow, sheet flow and so on concurrently, which is good to increase partial pressure of oxygen rapidly, At the same time fluctuation of thorax caused by increasing oxygen flow into airway is good to let out CO2. 
    B. Jet oxygen feeding is supported by pressure when inspiration and secure certain PEEP effect when feeding oxygen, So as to reach good effectiveness of oxygen feeding. 
    C. Accumulator jar, it can be used while being charged and can last for four hours after having been charged. 
    D. Alarm system with sound and light when lack of electric quantity or airway pressure. 
    E. 300CG chooses digital display of import pressure sensor. 
    F. 300CG has three kinds of airway limited pressure alarm for adult, child and infant. 
    G. The device disposes pressure humidifier which has good humidigying effectiveness. 

    Specifications: 

    Frequency: 10~150 breaths/min 
     Power supply:AC220V?2V 50HZ?HZ 
     I/E ratio:1:1,1:1.5~ 1:3 and 3:1 
     Driving Pressure :0~0.15MPa  
     SIGH:6breaths/min, I/E=1:4 
     Pressure Regulator Limit:0.30MPa 
     CPAP:not less than 1KPa  
     Oxygen Concentration Adjustable:40%-90% 
     Process Ventilation:T=10min,Infinite recursion 
    ProI:
     f(150):f(35)=7:3 
    ProII:
     f(35):f(150)=7:3 
     Alarm:Alarm with light and sound for no gas or no power or airway pressure is over 
     Inner Battery:4Ah 12V 
     Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure),HFJV+SIGH(Sigh); Process ventilation I and Process ventilation II, Manual Control Mode


    Company:  Jiangxi TELI Anaesthesia & Respiration Equipment Co., Ltd.
  • TKR-300CG High-Frequency Jet Ventilator
    can ventilate with high frequency and is widely used for narcosis, respiration, medicine, surgery and peditarics to auxiliarily feed oxygen on ventilation management, ventilation treatment and first –aid anabiosis.
    Feature: 
    A. The device adopts impulse jet oxygen feeding technique with great flow rate of oxygen feeding in a shot while, when feeding oxygen, it adopts change mode major in reflux and many kinds of gas flow mechanism such as convection, laminar flow, sheet flow and so on concurrently, which is good to increase partial pressure of oxygen rapidly, At the same time fluctuation of thorax caused by increasing oxygen flow into airway is good to let out CO2. 
    B. Jet oxygen feeding is supported by pressure when inspiration and secure certain PEEP effect when feeding oxygen, So as to reach good effectiveness of oxygen feeding. 
    C. Accumulator jar, it can be used while being charged and can last for four hours after having been charged. 
    D. Alarm system with sound and light when lack of electric quantity or airway pressure. 
    E. 300CG chooses digital display of import pressure sensor. 
    F. 300CG has three kinds of airway limited pressure alarm for adult, child and infant. 
    G. The device disposes pressure humidifier which has good humidigying effectiveness. 

    Specifications: 

    Frequency: 10~150 breaths/min 
     Power supply:AC220V?2V 50HZ?HZ 
     I/E ratio:1:1,1:1.5~ 1:3 and 3:1 
     Driving Pressure :0~0.15MPa  
     SIGH:6breaths/min, I/E=1:4 
     Pressure Regulator Limit:0.30MPa 
     CPAP:not less than 1KPa  
     Oxygen Concentration Adjustable:40%-90% 
     Process Ventilation:T=10min,Infinite recursion 
    ProI:
     f(150):f(35)=7:3 
    ProII:
     f(35):f(150)=7:3 
     Alarm:Alarm with light and sound for no gas or no power or airway pressure is over 
     Inner Battery:4Ah 12V 
     Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure),HFJV+SIGH(Sigh); Process ventilation I and Process ventilation II, Manual Control Mode


    Company:  Jiangxi TELI Anaesthesia & Respiration Equipment Co., Ltd.
  • TKR-300JII Computerized High-Frequency First-Aid Ventilator
    The device has flexible car and respiratory salvaging equipment. Operate conveniently. It is suit to use in clinical salvaging in hospital, as car-mountedly in Respiratory rescue system, first –aid revivaling in field operation, field work.
     
    Feature 
    A .An opening system is designed to avoid leakage of airway, When ventilating, the intubation may have no casing bag. Little tube may be used for ventilation when resistance of expiration is small, so that mucosa won't be hurt easily. 
    B .Airway is open during ventilating, suction and ventilation can be done synchronously, so good effectiveness of oxygen combination can be shown without inspiration and expiration synchronizing. 
    C .Lower airway pressure is good to increase blood discharge and decrease cerebra pressure 
    D .Suction device, it driving negative pressure is adjustable. 
    E .Storage battery can be used continuously for four hours after full charged. 
    F .The system disposes completely with laryngoscope, inlet intubation, catheter of tracheotomy, nasal prongs tube, air tube and so on. 

    Specifications 
    Frequency:10150 breaths/min 
    I/E ratio:1:1, 1:1.5
    1:3 and inverse ratio 
    Driving Pressure:0
    0.15MPa 
    Negative pressure suction:-0.07
    0MPa
    CPAP: 0.1
    0.8kpa 
    Volume cycling ventilation: T=10min,I/E=1:1.5 
    Adults: T1(100bpm):T2(20bpm)=7:3 Regular frequency: Tidal volume≥400ml/breath Driving pressure:0.06mpa 
    Children: T1(100bpm):T2(30bpm)=7:3 Regular frequency: Tidal volume≥300ml/breath Driving pressure:0.04mpa 
    Storage battery:4Ah, 12V;Rechargeable 
    SIGH:6 bpm 
    Alarm: Alarm with sound and light when lack of power, or no air supply. 
    Maximum Output Oxygen Concentration:85% 
    Ventilation Mode: HFJV, CPAP, Volume cycling ventilation; HFJV+SIGH. 


    Company:  Jiangxi TELI Anaesthesia & Respiration Equipment Co., Ltd.
  • TKR-300JII Computerized High-Frequency First-Aid Ventilator
    The device has flexible car and respiratory salvaging equipment. Operate conveniently. It is suit to use in clinical salvaging in hospital, as car-mountedly in Respiratory rescue system, first –aid revivaling in field operation, field work.
     
    Feature 
    A .An opening system is designed to avoid leakage of airway, When ventilating, the intubation may have no casing bag. Little tube may be used for ventilation when resistance of expiration is small, so that mucosa won't be hurt easily. 
    B .Airway is open during ventilating, suction and ventilation can be done synchronously, so good effectiveness of oxygen combination can be shown without inspiration and expiration synchronizing. 
    C .Lower airway pressure is good to increase blood discharge and decrease cerebra pressure 
    D .Suction device, it driving negative pressure is adjustable. 
    E .Storage battery can be used continuously for four hours after full charged. 
    F .The system disposes completely with laryngoscope, inlet intubation, catheter of tracheotomy, nasal prongs tube, air tube and so on. 

    Specifications 
    Frequency:10150 breaths/min 
    I/E ratio:1:1, 1:1.5
    1:3 and inverse ratio 
    Driving Pressure:0
    0.15MPa 
    Negative pressure suction:-0.07
    0MPa
    CPAP: 0.1
    0.8kpa 
    Volume cycling ventilation: T=10min,I/E=1:1.5 
    Adults: T1(100bpm):T2(20bpm)=7:3 Regular frequency: Tidal volume≥400ml/breath Driving pressure:0.06mpa 
    Children: T1(100bpm):T2(30bpm)=7:3 Regular frequency: Tidal volume≥300ml/breath Driving pressure:0.04mpa 
    Storage battery:4Ah, 12V;Rechargeable 
    SIGH:6 bpm 
    Alarm: Alarm with sound and light when lack of power, or no air supply. 
    Maximum Output Oxygen Concentration:85% 
    Ventilation Mode: HFJV, CPAP, Volume cycling ventilation; HFJV+SIGH. 


    Company:  Jiangxi TELI Anaesthesia & Respiration Equipment Co., Ltd.