Ventilator| China Ventilator| Ventilator Products Manufacturers
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.
Select to
Page 4 of 6
  • Shangrila510 Ventilator- CE Marked

    Shangrila510 ventilator

    Multi-functional emergency transport ventilator
    Pneumatically driven electronically controlled  
    All parameters set in one step                         
    Simple operation, compact design, reliable performance.                                      
    Waveform display and multi-parameter monitoring  Backup apnea ventilation                   
    Flexible power supply: A/C, D/C, rechargeable build-in battery                                             
    CEmarked                                                                                                       
    Official emergency ventilator supplier for Beijing 2008 Olympics Games


    Company: China Shikang Medical Equipment Group Limited
  • Shangrila510 Ventilator- CE Marked

    Shangrila510 ventilator

    Multi-functional emergency transport ventilator
    Pneumatically driven electronically controlled  
    All parameters set in one step                         
    Simple operation, compact design, reliable performance.                                      
    Waveform display and multi-parameter monitoring  Backup apnea ventilation                   
    Flexible power supply: A/C, D/C, rechargeable build-in battery                                             
    CEmarked                                                                                                       
    Official emergency ventilator supplier for Beijing 2008 Olympics Games


    Company: China Shikang Medical Equipment Group Limited
  • Universal Ventilator SC-300/800

    l MAIN SPECIFICATIONS

    1. Respiration Modes: IPPV/ASSIST (VC,PC), SIMV, BIPAP, CPAP, VCV;

    2. Respiration frequency: 2 bpm99 bpm

    3. Inspiratory time: 0.2 s3 s

    4. Expiratory oxygen concentration: 21100%

    5. IPPV: 0kPa ~ 2kPa

    6. Inspiratory Pressure: 0kPa ~ 4kPa (Higher than IPPV)

    7. Inspiratory Triggering Flow: 1L/min ~ 25L/min

    8. TV: 30 mL ~ 2000 mL

    9. Monitor TV: 30ml ~ 2000ml MV: 0.5L/min ~ 30 L/min Airway pressure: 0kPa ~ 9kPa Expiratory oxygen concentration: 21100%

    10. Circumstance: Working condition: a)Environmental temperature: 540 b)Relative humidity: Less than 80% c)Ambient pressure: 860 hPa1060 hPa d)Power supply: AC 220 V±22V; 50 Hz±1Hz Internal Battery DC 12V Transportation and Storage Condition: a)Environmental temperature: -4055 b)Relative humidity: ≤93 % c)Ambient pressure: 500 hPa1060 hPa

    11. Working system: Continuous Running


    Company: China Shikang Medical Equipment Group Limited
  • Universal Ventilator SC-300/800

    l MAIN SPECIFICATIONS

    1. Respiration Modes: IPPV/ASSIST (VC,PC), SIMV, BIPAP, CPAP, VCV;

    2. Respiration frequency: 2 bpm99 bpm

    3. Inspiratory time: 0.2 s3 s

    4. Expiratory oxygen concentration: 21100%

    5. IPPV: 0kPa ~ 2kPa

    6. Inspiratory Pressure: 0kPa ~ 4kPa (Higher than IPPV)

    7. Inspiratory Triggering Flow: 1L/min ~ 25L/min

    8. TV: 30 mL ~ 2000 mL

    9. Monitor TV: 30ml ~ 2000ml MV: 0.5L/min ~ 30 L/min Airway pressure: 0kPa ~ 9kPa Expiratory oxygen concentration: 21100%

    10. Circumstance: Working condition: a)Environmental temperature: 540 b)Relative humidity: Less than 80% c)Ambient pressure: 860 hPa1060 hPa d)Power supply: AC 220 V±22V; 50 Hz±1Hz Internal Battery DC 12V Transportation and Storage Condition: a)Environmental temperature: -4055 b)Relative humidity: ≤93 % c)Ambient pressure: 500 hPa1060 hPa

    11. Working system: Continuous Running


    Company: China Shikang Medical Equipment Group Limited
  • Ventilator

     
    Main feature:    
    ◆     Be controlled by microprocessor. 
    ◆     Gas driven electronically controlled. 
    ◆     Used for adult and pediatric. 
    ◆     Color TFT 12.1-inch screen  
    ◆     PEEP function.  
    ◆     CPAP function. 
    ◆     SIGH function. 
    ◆     I/E function. 
    ◆     Compliance compensated function. 
    ◆     Inspiratory pressure and flow volume trigger function. 
    Main technical parameter:
    ◆     Mode: IPPV、IPPV+SIGH、A/C、SIMV、PCV、SPONT、MANU、CPAP, PSV (Optional)
    ◆     Tidal volume: 20—2000mL. 
    ◆     Frequency: 1-100/min 
    ◆     Inhalation time: 0~12s    (I:E ration: 4:1~1:8)
    ◆     Holding time: 0~6s
    ◆     Controlling pressure: 0.2~6.0KPa 
    ◆     PEEP/CPAP:0~4.0KPa
    ◆     Inhalation trigger: 
             Pressure -2.0~0kPa.   Flow :1~30L/min.  
    ◆     SIGH time: 1-5 times (every 100 times)  
    ◆     Oxygen concentration: 21%~100% (continual adjustable)
    ◆     Ventilation parameter monitoring: 
    Tidal volume, minute ventilation, frequency, inhalation time, airway peak pressure, PEEP, airway mean pressure, O2 concentration, Time-airway pressure waveform, Time- flow waveform, and trigger indicate.
    ◆     Alarm:( Audio-visual) 
    No tidal volume (asphyxia), minute ventilation is too high (low), airway pressure is too high (low), O2 concentration is too high (low), oxygen or air is not full, frequency is too high (under SPONT mode), AC power off, Back-up battery voltage is too low.
    ◆     Power off: 
    There will be audio and visual alarm indicates when power is off in unusual way, and the power will be supplied by back-up battery( battery working time≥3 hours).
    ◆     Gas resource: oxygen or depurative air. The given working pressure is 280kPa~600kPa 
    ◆     Power: ~220V   50Hz 
    Air compressor specification: 
    ◆     Output pressure: 0.4MPa±0.1Mpa 
    ◆     Continuous flow: 45L/min  
    ◆     Noise≤50dB(A) 
    ◆     Power: AC 220V, 50Hz  
    ◆     Working environment
             Temperature: +5℃—+40℃,Relative humidity: 20%—80%   
    ◆     Rating consume power: ≤650W

    Company: SHENZHEN CHENWEI ELECTRONIC CO.,LTD
  • Ventilator

     
    Main feature:    
    ◆     Be controlled by microprocessor. 
    ◆     Gas driven electronically controlled. 
    ◆     Used for adult and pediatric. 
    ◆     Color TFT 12.1-inch screen  
    ◆     PEEP function.  
    ◆     CPAP function. 
    ◆     SIGH function. 
    ◆     I/E function. 
    ◆     Compliance compensated function. 
    ◆     Inspiratory pressure and flow volume trigger function. 
    Main technical parameter:
    ◆     Mode: IPPV、IPPV+SIGH、A/C、SIMV、PCV、SPONT、MANU、CPAP, PSV (Optional)
    ◆     Tidal volume: 20—2000mL. 
    ◆     Frequency: 1-100/min 
    ◆     Inhalation time: 0~12s    (I:E ration: 4:1~1:8)
    ◆     Holding time: 0~6s
    ◆     Controlling pressure: 0.2~6.0KPa 
    ◆     PEEP/CPAP:0~4.0KPa
    ◆     Inhalation trigger: 
             Pressure -2.0~0kPa.   Flow :1~30L/min.  
    ◆     SIGH time: 1-5 times (every 100 times)  
    ◆     Oxygen concentration: 21%~100% (continual adjustable)
    ◆     Ventilation parameter monitoring: 
    Tidal volume, minute ventilation, frequency, inhalation time, airway peak pressure, PEEP, airway mean pressure, O2 concentration, Time-airway pressure waveform, Time- flow waveform, and trigger indicate.
    ◆     Alarm:( Audio-visual) 
    No tidal volume (asphyxia), minute ventilation is too high (low), airway pressure is too high (low), O2 concentration is too high (low), oxygen or air is not full, frequency is too high (under SPONT mode), AC power off, Back-up battery voltage is too low.
    ◆     Power off: 
    There will be audio and visual alarm indicates when power is off in unusual way, and the power will be supplied by back-up battery( battery working time≥3 hours).
    ◆     Gas resource: oxygen or depurative air. The given working pressure is 280kPa~600kPa 
    ◆     Power: ~220V   50Hz 
    Air compressor specification: 
    ◆     Output pressure: 0.4MPa±0.1Mpa 
    ◆     Continuous flow: 45L/min  
    ◆     Noise≤50dB(A) 
    ◆     Power: AC 220V, 50Hz  
    ◆     Working environment
             Temperature: +5℃—+40℃,Relative humidity: 20%—80%   
    ◆     Rating consume power: ≤650W

    Company: SHENZHEN CHENWEI ELECTRONIC CO.,LTD
  • Ventilator

     
    Main feature:
    ◆    Controlled by micro processor.
    ◆    Gas driven electronically controlled, time switch, volume control, pressure limit ventilation
    ◆    LCD display of ventilation parameters, preset parameters, alarm indication and breathing waveform
    ◆    PEEP, Inhalation platform, SIGH, I/E ventilation function
    ◆    IPPV、IPPV+SIGH、SIPPV (A/C) 、SIMV、SPONT, MANUAL ventilation modes
    Main Specification:
    ●     Power :AC 22OV士10%,50 Hz士2%  35VA
    ●     Built in battery: 12V, working time: >3hours
    ●     Working pressure: 0.4MPa±0.1MPa
    ●     Tidal volume: 50~1500ml
    ●     Frequency: 6~60/min
    ●     Inhalation time: 0.2~6s (I/E ratio 2:1-1:5)
    ●     Holding time: 0~2s
    ●     PEEP/CPAP : 0~2.0kpa
    ●     Inhalation trigger sensitivity: Pressure -0.2~+2.0 kpa.
    ●     SIGH : 1~5 times (every 100 times)
    ●     Ventilation Parameter monitoring:
           Tidal volume, minute ventilation, frequency, inhalation time, airway Pressure, waveform of time-airway pressure, pressure-volume loop (Optional)
    ●     Alarm:(Audible-visible)
           No tidal volume (asphyxia). minute ventilation too high(low), airway pressure too high(low),Oxygen or air not enough, frequency too high (in SPONT),AC power off, back-up battery voltage too low.

    Company: SHENZHEN CHENWEI ELECTRONIC CO.,LTD
  • Ventilator

     
    Main feature:
    ◆    Controlled by micro processor.
    ◆    Gas driven electronically controlled, time switch, volume control, pressure limit ventilation
    ◆    LCD display of ventilation parameters, preset parameters, alarm indication and breathing waveform
    ◆    PEEP, Inhalation platform, SIGH, I/E ventilation function
    ◆    IPPV、IPPV+SIGH、SIPPV (A/C) 、SIMV、SPONT, MANUAL ventilation modes
    Main Specification:
    ●     Power :AC 22OV士10%,50 Hz士2%  35VA
    ●     Built in battery: 12V, working time: >3hours
    ●     Working pressure: 0.4MPa±0.1MPa
    ●     Tidal volume: 50~1500ml
    ●     Frequency: 6~60/min
    ●     Inhalation time: 0.2~6s (I/E ratio 2:1-1:5)
    ●     Holding time: 0~2s
    ●     PEEP/CPAP : 0~2.0kpa
    ●     Inhalation trigger sensitivity: Pressure -0.2~+2.0 kpa.
    ●     SIGH : 1~5 times (every 100 times)
    ●     Ventilation Parameter monitoring:
           Tidal volume, minute ventilation, frequency, inhalation time, airway Pressure, waveform of time-airway pressure, pressure-volume loop (Optional)
    ●     Alarm:(Audible-visible)
           No tidal volume (asphyxia). minute ventilation too high(low), airway pressure too high(low),Oxygen or air not enough, frequency too high (in SPONT),AC power off, back-up battery voltage too low.

    Company: SHENZHEN CHENWEI ELECTRONIC CO.,LTD
  • Ventilator

     
    Main Feature:
    ◆    Gas driven electronically controlled.
    ◆    Time switch, volume control, pressure limit ventilation mode.
    ◆    I:E function
    ◆    LCD display ventilation parameters, preset parameters alarm indication and breathing waveform
    ◆    Applied for adult and child
    Main Specification:
    ●     Power : AC 110~22OV士10%,50 Hz~60Hz士1Hz, DC 12V 1.5A.
    ●     Mode: IPPV, IPPV+SIGH, A/C (SIPPV), SIMV, SPONT, MANUAL
    ●     Tidal volume: 0~1.5L
    ●     Ventilation volume per minute: 0L~20L
    ●     Frequency: 4~99/min. (1~40/min under SIMV)
    ●     I/E Ratio: 3:1~1:5
    ●     Inhalation trigger pressure:-2.0~+2.0Kpa
    ●     O2 concentration: 48~100% adjustable.
    ●     Pressure limitation: 1~5.5KPa
    ●     Safety Pressure ≤6KPa
    ●     Ventilation monitoring:
           Tidal volume,Minute ventilation,Frequency,Airway Pressure. Waveform of time-airway Pressure.
    ●     SPONT inhalation triggers indication, power indication.
    ●     Alarm: (Audible and visible reminding)
           No tidal volume, ventilation volume is too high (low) , airway Pressure is too high (low), frequency is too high, AC Power off , back up battery voltage is too low
    ●     Gas source: Oxygen or Purify air
    ●     Working Pressure: 0.4Mpa. Allowable range: 0 .3~0.5MPa
    ●     O2 cylinder: 3L (Max Pressure 15MPa)
    ●     Internal back-up battery: DC 12V ≥3 hours.
    ●     Weight: ≤4Kg
    ●     Volume: 310mm x 190mm x 115mm  (L x H x W).
    ●     Reserve Condition: Temperature:-10~40℃,Relative humidity: ≤90%
    ●     Working condition: Temperature:5~40℃,.Relative humidity:≤80%

    Company: SHENZHEN CHENWEI ELECTRONIC CO.,LTD
  • Ventilator

     
    Main Feature:
    ◆    Gas driven electronically controlled.
    ◆    Time switch, volume control, pressure limit ventilation mode.
    ◆    I:E function
    ◆    LCD display ventilation parameters, preset parameters alarm indication and breathing waveform
    ◆    Applied for adult and child
    Main Specification:
    ●     Power : AC 110~22OV士10%,50 Hz~60Hz士1Hz, DC 12V 1.5A.
    ●     Mode: IPPV, IPPV+SIGH, A/C (SIPPV), SIMV, SPONT, MANUAL
    ●     Tidal volume: 0~1.5L
    ●     Ventilation volume per minute: 0L~20L
    ●     Frequency: 4~99/min. (1~40/min under SIMV)
    ●     I/E Ratio: 3:1~1:5
    ●     Inhalation trigger pressure:-2.0~+2.0Kpa
    ●     O2 concentration: 48~100% adjustable.
    ●     Pressure limitation: 1~5.5KPa
    ●     Safety Pressure ≤6KPa
    ●     Ventilation monitoring:
           Tidal volume,Minute ventilation,Frequency,Airway Pressure. Waveform of time-airway Pressure.
    ●     SPONT inhalation triggers indication, power indication.
    ●     Alarm: (Audible and visible reminding)
           No tidal volume, ventilation volume is too high (low) , airway Pressure is too high (low), frequency is too high, AC Power off , back up battery voltage is too low
    ●     Gas source: Oxygen or Purify air
    ●     Working Pressure: 0.4Mpa. Allowable range: 0 .3~0.5MPa
    ●     O2 cylinder: 3L (Max Pressure 15MPa)
    ●     Internal back-up battery: DC 12V ≥3 hours.
    ●     Weight: ≤4Kg
    ●     Volume: 310mm x 190mm x 115mm  (L x H x W).
    ●     Reserve Condition: Temperature:-10~40℃,Relative humidity: ≤90%
    ●     Working condition: Temperature:5~40℃,.Relative humidity:≤80%

    Company: SHENZHEN CHENWEI ELECTRONIC CO.,LTD
Select to
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.
Page 4 of 6    4
Go to Page