Baby Incubator| China Baby Incubator| Baby Incubator Products Manufacturers
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.
Select to
Page 4 of 6
  • Infant incubator

    Based on YP-90, YP-90B is configured with fixed Neonate Bilirubin Phototherapy Equipment model: XHZ-90 (with blue fluorescence lamps)

    Based on YP-90, YP-90B is configured with fixed Neonate Bilirubin Phototherapy Equipment model: XHZ-90L (with LED bulb) as optional;

    Weighing system and Monitor shelf is optional.


    Company: Ningbo David Medical Device Co., Ltd.
  • Infant incubator

    ased on YP-90A, YP-90AB is configured with fixed Neonate Bilirubin Phototherapy Equipment model: XHZ-90 (with blue fluorescence lamps)

    Based on YP-90A, YP-90AB is configured with fixed Neonate Bilirubin Phototherapy Equipment model: XHZ-90L (with LED bulb) as optional;

    Weighing system and Monitor shelf is optional.


    Company: Ningbo David Medical Device Co., Ltd.
  • Low-temperature Incubator
    Low-temperature Incubator (SHP
    intelligentized microprocessor control

    Summary
    Extensiveapplication in deposit culture medium, serum, medicine as well asmicroorganism training and environmental testing etc..

    Features
    Withmirror surface in stainless steel, foursquare semicircle transition,shelf support handling freely, easy for cleaning within the case.
    Choose new handing of fuzzy logic controller, fast to set value, accuracy and stable in operation.
    Internationalbrand compressor and circulating fan, environmental protectioncryogenR134a,with high efficiency and low power consumption,promoting energy saving.
    Independent temperature-limited alarmsystem can automatically interrupt when it is over limit temperature,ensuring the safe operation of the experiment, with noaccident.(Option)
    4-20mA standard current signal, RS485 interface may link grapher and calculating machine.(Option)
    Thereis a 50mm instruction connection hole on the left side of the case,easy for testing operation and temperature measurement.

    Company: YangZhou HongDu ELECTRONIC CO.,LTD
  • Heating Incubator
    Heating Incubator DNP)
    Microprocessor contrlol(with timing function)

    Summary
    Providedas a necessary equipment for scientific research to colleges as well asbiological Agricultural and scientific research departments for storageof mould and biology cultivation.

    Featires
    Microprocessorcontroller with timing function ensure a stable and reliableuse.(Intelligent programmable LCD temperature controller is an option)
    Independent alarm system for temperature-limiting ensures experiments run safely and no accident would happen.(Option)
    Anglass door in chamber is easy for observation. When the glass dooropens, breeze circul ation and heating system will automatically stop,Which ensures no disadvantage of convection.
    Specular stainless steel chamber, film heating method ensure a quick heating.
    Recorderand printer are options which can print or record set parameters andtrace variation curves of temperature (420mA standard signal).(Option)

    Company: YangZhou HongDu ELECTRONIC CO.,LTD
  • AJ-2301 Infant Incubator

    Feature:
    Simultaneously air temperature and set temperature display.
    Alarm functions for safety includes
    Power failure fan failure
    Over temperature temperature deviation
    Temperature probe failure
    >37°C temperature setting
    A keypad locks helps to prevent inadvertent changes to settings.
    Trough for pulling and pushing add the water and wash is convenient.
    Heater is electrically cut off if air /skin temperature inside incubator exceed 40°C.
    The infant bed inclination angle is adjustable.
    Technical specification:
    Electrical requirement: 220V±10%/50HZ±2%
    Power supply : ≤420VA
    Air Temperature control range: 25℃~38℃
    Temperature fluctuation: ≤0.5℃
    Uniformity of mattress temperature: ≤0.8℃
    Warm-up time: ≤45min
    Internal noise level: ≤55dB
    Operation condition:
    Environment temperature: 25℃~38℃
    Environment relative humidity: 30%~75%RH
    Environment air velocity of flow: <0.3m/s
    Package:
    Gross weight: 110kg
    Net weight: 80kg
    Measure: 1100*780*860mm

     


    Company: ANJUE IMPORT&EXPORT CO., LTD.
  • Infant Balance
    Specification
    Digital display
    Max.Capacity: 30kg*0.01kg/66Ib*0.5oz


    Company: ANJUE IMPORT&EXPORT CO., LTD.
  • Infant Incubator

    Function features:
    ☆ Microprocessor based servo controlled
      temperature system
    ☆ Temperature displayed by LED
    ☆ Alarms functions:
       Power failure; over
       temperature;
       temperature deviation;
       temperature sensor failure;
       fan failure;
    ☆ >37℃ temperature setting
    ☆ A keypad lock prevent inadvertent changes
      the setting
    ☆ Humidity is adjustable continuously
    ☆ Heating power displayed on panel
    ☆ A second thermal cut-off function for more safety
    ☆ The infant bed inclination angle is adjustable
    ☆ Trough for pulling and pushing ,which is
      convenient to add the water and wash
    ☆ Fan with low noise and long life-span
    ☆ Temperature deviation and over temperature
      could be amended in front panel directly
    ☆ Silence/reset button for alarms
    ☆ six operating windows,two side operating
      windows can be swiveled
    ☆ Heater is electrically cut-out if air temperature
      inside incubator exceed 40℃
    ☆ Cabinet with three drawers
    Standard configuration
    Main body(including the transparent hood,control system,infant bed,water trough),I.V.pole, mattress, cabinet, silence castors.

    Optional parts:
     Phototherapy up side unit;
     phototherapy from up and down sides;
     RS232(485)conncector;Tray/pole;
     Infant bed pulled from side door;
     Infant bed pulled from side and front door;
     Double wall hood.

    Technical data:
     ※ Power supply : AC 110/220V 60/50Hz
      ※ Power input : ≤420VA

    Operating conditions:
     ※ Environment temperature: 20℃~30℃
     ※ Environment relative humidity: 30%~75%RH
     ※ Environment air velocity of flow: <0.3m/s
     ※ Air Temperature control range: 25℃~38℃
     ※ Temperature fluctuation: +0.5℃
     ※ Uniformity of mattress temperature: ≤0.8℃
     ※ Humidity accuracy: ≤10%RH
     ※ Warm-up time: ≤45min
     ※ Internal noise level: ≤55dB
     ※ Infant bed tilt angle : +10º
     ※ Mattress size: 65cm(L)×37cm(W)
     ※ Trough capacity: 1200ml
     ※ Air filter:0.5um
    Package:
    Each unit is packed in two wooden crate:
      ※Size (control unit and cabinet):120×70×96cm
      N.W.:80Kg G.W.:110Kg
     ※ Hood: 97×56×63cm
       N.W.:15Kg G.W.:40Kg
    Transport and storage:
     Environment Temp:-10℃--+70℃
     Environment Relative Humidity: ≤80%
     Atmospheric Pressure: 500~1060Hpa



     


    Company: Qingdao Medicon Trading Company
  • Infant Incubator (B-2000)

    SPECIFICATIONS:
    Model: B-2000
    POWER
    Power Requirements: AC220V 10%, 50Hz 2%
    Power Input: ≤450VA
    Refer to IEC60601-1, this equipment belongs to Class I, Type B. Its operation is Continuous.
    ALARM
    Power Alarm
    Power Failure: Activates if primary power to the Incubator
    Fails or the power wire is accidentally
    Disconnected from the wall receptacle.

    Fan Alarm
    Fan Failure: Activates if Fan motor malfunctions. Sensor Alarm
    Air Sensor Failure: Air Sensor malfunction, refer unit to service.
    Sensor Out of Position: Activated when Sensor is not in correct position To perform calibration or continue operation.
    Skin Sensor Disconnected: Activated during Skin Control Mode when Skin Sensor is disconnected from Temperature Controller. Skin Sensor Failure: Activated when Skin Sensor malfunctions.
    Deviation Alarm High Air Temperature: Activated if displayed Air Temperature is 1.5 centigrade above set point
    Low Air Temperature: Activated if displayed Air Temperature 2.5centigrade below set point

    Skin Temperature: Activated if displayed Skin Temperature is 1.0 centigrade above set point
    Low Skin Temperature: Activated if displayed Skin Temperature is 1.0Over Temperature Alarm
    Over Air Temperature: Activated when displayed Air TemperatureWas approach 38centigrade for set temperature ≤37centigrade, Or approach 40centigrade for set temperature >37centigrade in Air Mode.

    Over Skin Temperature: Activated when displayed Skin Temperature was approach 38centigrade for set temperature ≤37centigrade, Or approach 39centigrade for set temperature >37centigrade in Skin Mode. System Alarm
    System Failure: Activated if Temperature Control System malfunctions.

    TEMPERATURE CONTROLRANGEAND CORRELATIVE SPECIFICATIONS
    Air Temperature: 20centigrade ~37centigrade, for set temperature ≤37centigrade
    37centigrade ~39centigrade, for set temperature >37centigrade
    Skin Temperature: 20centigrade ~37centigrade, for set temperature ≤37centigrade
    37centigrade~38centigrade, for set temperature >37centigrade
    Temperature Rise Time: ≤30min
    Temperature Variability: 0.5centigrade
    Temperature Uniformity: ≤ 1 centigrade
    Skin Sensor Precision: ≤0.3centigrade
    ENVIRONMENT REQUIREMENT

    Environment Temperature
    Operation Temperature Range+20centigrade ~+30centigrade
    Store Temperature Range -40centigrade ~+70centigrade
    Environment Humidity
    Operation Humidity Range: 30%~75%
    Store Humidity Range: ≤80%
    Atmospheric Pressure Range: 500hPa~1060hPa
    OTHER SPECIFICATION
    Noise Level Within Hood Environment ≤55dB(Environment noise below 45dB Carbon Dioxide (CO2) Level within the Hood Less than 0.5% when a mixture of CO2

    In air is delivered at 750ml/min
    At point 10cm above the center of the mattress.
    Air Velocit y Over Mattress less than: 0.35m/s
    Infant Bed Max Load: 10kg
    Transfusion Shelf Max Load: 2kg
    Shelf Max Load:
    Cabinet Max Load: 6kg


    Company: China Shikang Medical Equipment Group Limited
  • Infant Incubator (B-2000)

    SPECIFICATIONS:
    Model: B-2000
    POWER
    Power Requirements: AC220V 10%, 50Hz 2%
    Power Input: ≤450VA
    Refer to IEC60601-1, this equipment belongs to Class I, Type B. Its operation is Continuous.
    ALARM
    Power Alarm
    Power Failure: Activates if primary power to the Incubator
    Fails or the power wire is accidentally
    Disconnected from the wall receptacle.

    Fan Alarm
    Fan Failure: Activates if Fan motor malfunctions. Sensor Alarm
    Air Sensor Failure: Air Sensor malfunction, refer unit to service.
    Sensor Out of Position: Activated when Sensor is not in correct position To perform calibration or continue operation.
    Skin Sensor Disconnected: Activated during Skin Control Mode when Skin Sensor is disconnected from Temperature Controller. Skin Sensor Failure: Activated when Skin Sensor malfunctions.
    Deviation Alarm High Air Temperature: Activated if displayed Air Temperature is 1.5 centigrade above set point
    Low Air Temperature: Activated if displayed Air Temperature 2.5centigrade below set point

    Skin Temperature: Activated if displayed Skin Temperature is 1.0 centigrade above set point
    Low Skin Temperature: Activated if displayed Skin Temperature is 1.0Over Temperature Alarm
    Over Air Temperature: Activated when displayed Air TemperatureWas approach 38centigrade for set temperature ≤37centigrade, Or approach 40centigrade for set temperature >37centigrade in Air Mode.

    Over Skin Temperature: Activated when displayed Skin Temperature was approach 38centigrade for set temperature ≤37centigrade, Or approach 39centigrade for set temperature >37centigrade in Skin Mode. System Alarm
    System Failure: Activated if Temperature Control System malfunctions.

    TEMPERATURE CONTROLRANGEAND CORRELATIVE SPECIFICATIONS
    Air Temperature: 20centigrade ~37centigrade, for set temperature ≤37centigrade
    37centigrade ~39centigrade, for set temperature >37centigrade
    Skin Temperature: 20centigrade ~37centigrade, for set temperature ≤37centigrade
    37centigrade~38centigrade, for set temperature >37centigrade
    Temperature Rise Time: ≤30min
    Temperature Variability: 0.5centigrade
    Temperature Uniformity: ≤ 1 centigrade
    Skin Sensor Precision: ≤0.3centigrade
    ENVIRONMENT REQUIREMENT

    Environment Temperature
    Operation Temperature Range+20centigrade ~+30centigrade
    Store Temperature Range -40centigrade ~+70centigrade
    Environment Humidity
    Operation Humidity Range: 30%~75%
    Store Humidity Range: ≤80%
    Atmospheric Pressure Range: 500hPa~1060hPa
    OTHER SPECIFICATION
    Noise Level Within Hood Environment ≤55dB(Environment noise below 45dB Carbon Dioxide (CO2) Level within the Hood Less than 0.5% when a mixture of CO2

    In air is delivered at 750ml/min
    At point 10cm above the center of the mattress.
    Air Velocit y Over Mattress less than: 0.35m/s
    Infant Bed Max Load: 10kg
    Transfusion Shelf Max Load: 2kg
    Shelf Max Load:
    Cabinet Max Load: 6kg


    Company: China Shikang Medical Equipment Group Limited
  • Infant Radiant Warmer

    BNT-2000B Infant Radiant Warmer

    STANDARD COMPOSITION

    Temperature Control Mode: pre-heating control, servo control & manual control;
    Instant Parameter Display: set temp, skin temp, heat power rate;
    Built-in APGAR Timer and >37 preset function
    Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
    Tilting Bed with Rotary Radiant Head;
    X-ray Cassette Tray under infant bed, examination light of high illuminance;
    Use anti-blast quartz infrared tube as radiant heating source;
    With phototherapy unit;
    With two oxygen cylinders;
    With Suction, with neonate resuscitation.

     

     


    Company: China Shikang Medical Equipment Group Limited
Select to
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.