AJ-2205 Ventilator are suitable for the children, the adults, widely used in the hospital wards, ICU, A & E. Main technical parameters *Display mode 5.7 inch high clear display *Ventilation mode IPPV SIPPV SIMV PEEP MANUAL(SPONT) SIGH *Ventilation parameters Tidal volume 50~1500ml Frequency 4~60bpm I:E 2:1~1:8 Trigger sensitivity -0.1~-1.0Kpa PEEP 0~1.0Kpa Pressure control 1~6Kpa SIGH 1.5 breath times *Ventilation monitoring parameters Tidal volume,Ventilation,IPPV ratio,breath/expiratory ratio,peak pressure,Pressure-time wave,velocity-time wave,total respiratory rate,airway pressure wave,PEEP,breath pressure trigger *Monitoring oxygen concentration 21%~100% (choose and match ) *Security Alert System Oxygen concentration alarm (choose and match ) Upper limit setting range 50%~100% Low limit setting range 15%~50% Airway pressure alarm Upper limit setting range 1 ~6 KPa Low limit setting range 0.4~2 KPa Minute volume alarm Upper limit setting range 3.0~30L/min Low limit setting range 1~10L/min Asphyxia alarm The machine will give sound and light alarm if there is no tida volume input in 15s Power failure alarm. *Power AC 220V±10% 50Hz±1Hz UPS,Battery (choose and match)
General Description Scanning mode : Convex / linear of electronics ( 128 elements) Adopt DBF digital wave-beam forming technology Display mode: B,B/B,B/M,M working frequency: 2.0MHZ~10MHZ Measurements: distance, circumference, area, volume, heart function, pregnancy period etc Character presentation: date, time, patient number, patient name, probe mark, frequency, focusing position and image annotation etc. USB port Software measurement: heart, obstetric, gynecology and urology. Puncturing guide function, partial magnification function Standard Configuration Main unit 10" high resolution monitor 3.5MHz Multi-frequency Convex Probe Options 4.0-9.0MHz high frequency linear probe trans-vaginal probe rectal probe 2.0/3.5/5.0MHz heart probe Cine loop Thermal Paper Printer Trolley
Specification Measuring Range 0-240g/L Tolerance ≤2% Linear Range ≤5% FS Dilution Ratio 1:251 Testing Time ≤4S (maximum absorption) Stability ≤1g/L/h (25±10℃) Continuous Working time ≥10 hours Sample Absorption 1~9ml, ten grades adjustable Standard setting 0~240g/L adjustable (whole number times of ten) Electrical AC110/120/220V±10% (50/60Hz) Power Consumption ≤10W Conditions (Humidity ≤85%,Temperature 25℃±10℃,Air pressure 86kpa~106kpa)
This is a kind of part laminar flow hood providing clean environment free of bacteria and dust, which is widely used in medical and health, pharmacy, chemical experiments and such fields. Feature 1.Vertical flow, close table to keep exterior airflow out effectively and control the stimulation of peculiar smell to human body. 2.Make use of adjustable fan unit system and touching switch to adjust the voltage so that make sure the wind speed of working area is always kept in perfect condition. 3.May operate in two sides freely and conveniently. 4.The material of working platform surface is stainless steel.
Specifications X-ray Generator: 120kV, 5kW,41kHz X-Ray Tube: Rotation anode, 3000rpm Dual focal spot: 0.3/0.6mm Anode heat storage capacity: 150/600kJ or 200/800kHU Fluoroscopic/Radiographic kV range:40~120kV Fluoroscopic mA range:0.5~5mA Pulsed fluoroscopy:40~120kV,0.5~5mA Boost fluoroscopy:40~120kV, 5~10mA Photograph(30~60mA): 40~120kV,1~250mAs,20mA CCD camera: 768×576×8bit;360° Image intensifier: 9″/6″/4.5″( Image unit ) TV monitor: 2 Units, 14″,50Hz,1000Line X-Ray grid:40Line/cm, 8:1, 1m System resolution:14Lp/cm Gray scale:8 Bit Image brightness level:≥8 Image storage:LIH,6~8 Frames Collimator:Iris + Parallel shutter Vertical travel:400mm Horizontal travel:200mm Orbital movement:+90° ~-25° Wag range:±12.5° Rotation about horizontal axis:±180° Console:±90° Focus - 1.1 distance:1000mm Free space in arc:800mm Depth in arc:630mm Accept cassette sizes: 10″×12″ L×W×H (cm3): 190 × 790 ×196; 76× 54 ×155.2 Packing L×W×H (cm3): 244 × 85 ×168; 80 × 70 ×130 Weight (Kg): 530Kg
General Description Scanning mode : Convex / linear of electronics ( 128 elements) Adopt DBF digital wave-beam forming technology Display mode: B,B/B, B/M,M Working frequency: 2.0MHZ~10MHZ Measurements: distance, circumference, area, volume, heart function, pregnancy period etc. Character presentation: date, time, patient number, patient name, probe mark, frequency, focusing position and image annotation etc. USB port Software measurement: heart, obstetric, gynecology and urology,Puncturing guide function, partial magnification function Standard Configuration Main unit 3.5MHz Multi-frequency Convex Probe 15 inches SVGA monitor Options 5.0-7.0MHz high frequency linear probe Trans-vaginal probe Rectal probe 2.0/3.5MHz heart probe Cine loop Thermal Paper Printer
Disposable LED penlight Suitable for bulk usage 2*AAA carton batteries are not changeable The color is able to be chaged as customes requirement
Replaceable battery penlight LED penlight Requires 2-AAA cell carbon battery (not included) Aluminum tube in white,black or silver
· CLIA Waived · 60 tests/hour · Internal memory of last 1000 readings · Virtually noiseless · Compact space saving design · Large bright LCD screen · Results in 60 seconds · Connectivity to the LIS/HIS with Rapid Response POCDA Software · Special PROMOTIONAL OFFER PROMOTIONAL OFFER! Receive 10 FREE BOTTLES of Rapid Response Urinanalysis Reagent Strips with the purchase of a Rapid Response 100N Urine Analyzer. Call us for details!