  • Anesthesia system

    Main feature:
    ◆      Meet the Standard of GB 9706.29-Medical electrical equipment―Part 2: Particular requirements for the safety and essential performance of anaesthsia systems
    ◆      Be used for closed、semi-closed、semi-open inhalation anaesthesia, controlled or assisted ventilation, monitoring and display of the ventilation parameters.
    ◆      Applied for adult and child.
    ◆      Compacted breathing system meets the standard of ISO 8835-2. Good airtight, easy to operation, clearance and sterilization.
    ◆      Vaporizer meets the standard of ISO 8835-4. Accurate concentration, temperature、flow and pressure compensation technology. Various options of Isoflurane, Enflurane, and Sevoflurane.
    ◆      Anaesthesia ventilator meets the standard of ISO 8835-5.
             Gas driven and electrically controlled
             LCD screen
             IPPV、SIPPV、SIMV ventilation mode
             Inhalation platform and PEEP function
             Alarm, indication and protection functions for high pressure、leadoff and apnea
             Built-in battery for backup power source
    Main technical specification:
    ●       Power : AC 22OV,50Hz
    ●       Gas: O2, N2O          Working pressure: 0.28MPa~0.6MPa
    ●       Flowmeter
             ――Adjusting range
             O2 flowmeter (Double tubes): 0.1~10L/min
             N 2O flowmeter (Double tubes): 0.1~10L/ min       
             ――Interlock device to ensure the O2 concentration not less than 25%.
    ●       Vaporizer: (Isoflurane, Enflurane, sevoflurane.  Double or single vaporizer option)
             Range of concentration: 0~5%
             Temperature、flow and pressure compensation technology
    ●       Adjusting range of main ventilation parameters
             Frequency: 1/min~100/min
             I/E Ratio: 2:1~1:6
             Tidal Volume: 0L~1.5L
    ●       Ventilation parameter monitoring:
             Digital display: tidal volume, minute ventilation, frequency, airway pressure, O2 Concentration, and waveforms.
    ●       Alarm, indication and protection for;
             Power off, low voltage of battery, minute ventilation beyond the limit, pressure beyond the limit, O2 concentration beyond the limit, Apean, and insufficiency of O2, etc.

    Company: SHENZHEN CHENWEI ELECTRONIC CO.,LTD
  • Anesthesia system

    Main feature:
    ◆     Meet the Standard of GB 9706.29-Medical electrical equipment―Part 2: Particular requirements for the safety and essential performance of anaesthsia systems
    ◆     Be used for closed、semi-closed、semi-open inhalation anaesthesia, controlled or assisted ventilation, monitoring and display of the ventilation parameters.
    ◆     Applied for adult and child.
    ◆     Compacted breathing system meets the standard of ISO 8835-2. Good airtight, easy to operation, clearance and sterilization.
    ◆     Vaporizer meets the standard of ISO 8835-4. Accurate concentration, temperature、flow and pressure compensation technology. Various options of Isoflurane, Enflurane, and Sevoflurane.
    ◆     Anaesthesia ventilator meets the standard of ISO 8835-5.
            Gas driven and electrically controlled
            Big TFT screen
            IPPV, SIMV, PCV ventilation mode
            Inhalation platform and PEEP function
            Volume and pressure control
            Compliance compensation function
            Alarm, indication and protection functions for high pressure、leadoff and apnea
            Built-in battery for backup power source
    Main technical specification:
    ●      Power : AC 22OV,50Hz
    ●      Gas: O2, N2O, Air      Working pressure: 0.28MPa~0.6MPa
    ●      Flowmeter
            ――Adjusting range
            O2 flowmeter (Double tubes): 0.1~10L/min
            N 2O flowmeter (Double tubes): 0.1~10L/ min       
            Air flowmeter (Single tube): 0.1~10L/min
            ――Interlock device to ensure the O2 concentration not less than 25%.
    ●      Vaporizer: (Isoflurane, Enflurane, sevoflurane.  Double or single vaporizer option)
            Range of concentration: 0~5%
            Temperature、flow and pressure compensation technology
    ●      Adjusting range of main ventilation parameters
            Frequency: 1/min~100/min
            I/E Ratio: 4:1~1:8
            Tidal Volume: 0L~1.5L
    ●      Ventilation parameter monitoring:
            Digital display: tidal volume, minute ventilation, frequency, airway pressure, O2 Concentration, lung compliance, and waveforms.
    ●      Alarm, indication and protection for;
            Power off, low voltage of battery, minute ventilation beyond the limit, pressure beyond the limit, O2 concentration beyond the limit, Apean, and insufficiency of O2, etc.

    Company: SHENZHEN CHENWEI ELECTRONIC CO.,LTD
  • Anesthesia system

    Main feature:
    ◆     Meet the Standard of GB 9706.29-Medical electrical equipment―Part 2: Particular requirements for the safety and essential performance of anaesthsia systems
    ◆     Be used for closed、semi-closed、semi-open inhalation anaesthesia, controlled or assisted ventilation, monitoring and display of the ventilation parameters.
    ◆     Applied for adult and child.
    ◆     Compacted breathing system meets the standard of ISO 8835-2. Good airtight, easy to operation, clearance and sterilization.
    ◆     Vaporizer meets the standard of ISO 8835-4. Accurate concentration, temperature、flow and pressure compensation technology. Various options of Isoflurane, Enflurane, and Sevoflurane.
    ◆     Anaesthesia ventilator meets the standard of ISO 8835-5.
            Gas driven and electrically controlled
            Big TFT screen
            IPPV, SIMV, PCV ventilation mode
            Inhalation platform and PEEP function
            Volume and pressure control
            Compliance compensation function
            Alarm, indication and protection functions for high pressure、leadoff and apnea
            Built-in battery for backup power source
    Main technical specification:
    ●      Power : AC 22OV,50Hz
    ●      Gas: O2, N2O, Air      Working pressure: 0.28MPa~0.6MPa
    ●      Flowmeter
            ――Adjusting range
            O2 flowmeter (Double tubes): 0.1~10L/min
            N 2O flowmeter (Double tubes): 0.1~10L/ min       
            Air flowmeter (Single tube): 0.1~10L/min
            ――Interlock device to ensure the O2 concentration not less than 25%.
    ●      Vaporizer: (Isoflurane, Enflurane, sevoflurane.  Double or single vaporizer option)
            Range of concentration: 0~5%
            Temperature、flow and pressure compensation technology
    ●      Adjusting range of main ventilation parameters
            Frequency: 1/min~100/min
            I/E Ratio: 4:1~1:8
            Tidal Volume: 0L~1.5L
    ●      Ventilation parameter monitoring:
            Digital display: tidal volume, minute ventilation, frequency, airway pressure, O2 Concentration, lung compliance, and waveforms.
    ●      Alarm, indication and protection for;
            Power off, low voltage of battery, minute ventilation beyond the limit, pressure beyond the limit, O2 concentration beyond the limit, Apean, and insufficiency of O2, etc.

    Company: SHENZHEN CHENWEI ELECTRONIC CO.,LTD
  • Anesthesia system

    Main feature:
    ◆      Abide by the Standard of GB 9706.29-Medical electrical equipment―Part 2: Particular requirements for the safety and essential performance of anaesthsia systems
    ◆      Be used for closed、semi-closed、semi-open inhalation anaesthesia, controlled or assisted ventilation, monitoring and display of the ventilation parameters.
    ◆      Applied for adult and child.
    ◆      Compacted breathing system meets the standard of ISO 8835-2. Good airtight, easy to operation, clearance and sterilization.
    ◆      Vaporizer meets the standard of ISO 8835-4. Accurate concentration, temperature、flow and pressure compensation technology. Various options of Isoflurane, Enflurane.
    ◆      Anaesthesia ventilator meets the standard of ISO 8835-5.
             Gas driven and electrically controlled
             IPPV, MANUAL ventilation
             Alarm, indication and protection functions for high pressure、leadoff and apnea
    Main technical specification:
    ●       Power : AC 22OV,50Hz
    ●       Gas: O2, N2O          Working pressure: 0.28MPa~0.6MPa
    ●       Flowmeter
             ――Adjusting range
             O2 flowmeter : 01~10L/min
             N 2O flowmeter: 0.1~10L/ min       
             ――Interlock device to ensure the O2 concentration not less than 25%.
    ●       Vaporizer: (Isoflurane, Enflurane.  Double or single vaporizer option)
             Range of concentration: 0~5%
             temperature、flow and pressure compensation technology
    ●       Adjusting range of main ventilation parameters
             Frequency: 6/min~60/min
             I/E Ratio: 2:1~1:6
             Tidal Volume: 0~1.5L
    ●       Ventilation parameter monitoring:
             Digital display: tidal volume, minute ventilation, frequency, airway pressure
             Alarm, indication and protection for;
             Power off, low voltage of battery, minute ventilation beyond the limit, pressure beyond the limit, and insufficiency of O2, etc.

    Company: SHENZHEN CHENWEI ELECTRONIC CO.,LTD
  • Anesthesia system

    Main feature:
    ◆      Abide by the Standard of GB 9706.29-Medical electrical equipment―Part 2: Particular requirements for the safety and essential performance of anaesthsia systems
    ◆      Be used for closed、semi-closed、semi-open inhalation anaesthesia, controlled or assisted ventilation, monitoring and display of the ventilation parameters.
    ◆      Applied for adult and child.
    ◆      Compacted breathing system meets the standard of ISO 8835-2. Good airtight, easy to operation, clearance and sterilization.
    ◆      Vaporizer meets the standard of ISO 8835-4. Accurate concentration, temperature、flow and pressure compensation technology. Various options of Isoflurane, Enflurane.
    ◆      Anaesthesia ventilator meets the standard of ISO 8835-5.
             Gas driven and electrically controlled
             IPPV, MANUAL ventilation
             Alarm, indication and protection functions for high pressure、leadoff and apnea
    Main technical specification:
    ●       Power : AC 22OV,50Hz
    ●       Gas: O2, N2O          Working pressure: 0.28MPa~0.6MPa
    ●       Flowmeter
             ――Adjusting range
             O2 flowmeter : 01~10L/min
             N 2O flowmeter: 0.1~10L/ min       
             ――Interlock device to ensure the O2 concentration not less than 25%.
    ●       Vaporizer: (Isoflurane, Enflurane.  Double or single vaporizer option)
             Range of concentration: 0~5%
             temperature、flow and pressure compensation technology
    ●       Adjusting range of main ventilation parameters
             Frequency: 6/min~60/min
             I/E Ratio: 2:1~1:6
             Tidal Volume: 0~1.5L
    ●       Ventilation parameter monitoring:
             Digital display: tidal volume, minute ventilation, frequency, airway pressure
             Alarm, indication and protection for;
             Power off, low voltage of battery, minute ventilation beyond the limit, pressure beyond the limit, and insufficiency of O2, etc.

    Company: SHENZHEN CHENWEI ELECTRONIC CO.,LTD
  • Anesthesia Machine

    A new generation of anesthesia machine incorporating anesthesia, respiratory and monitoring functions.

    Company: Shanghai Medical Instruments Co.,Ltd.
  • Anesthesia Machine

    A new generation of anesthesia machine incorporating anesthesia, respiratory and monitoring functions.

    Company: Shanghai Medical Instruments Co.,Ltd.
  • Portable Veterinary Anesthesia Machine

    It is the newest and improved model of veterinary anesthesia machines,certificated with CE,ISO,TVU。
    It comes with a vaporizer of your choice: Isoflurane ,sevoflurane.Enflurane,Halothane
    I. RE902-C(v) veterinary anesthesia machine introduction
    RE902-C(v) veterinary anesthesia machine( circle and compact ) has full anaesthesia function. It is very small and portable. Inside there is a compact and built-in CO2 circle absorber system.
    The tidal volume of RE902-C(v) veterinary anesthesia machine is from 20ml to 1500ml, which can be used for 1kg animal to 100kg animals. It can be used universally at veterinary hospitals, animal labs and animal research institutes, and especially outside of the clinic while working with animals.
    RE902-C(v) veterinary anesthesia machine has many advantages for the anesthesiologist and anesthesia operation projects:
    1).The machine improves the medical equipment level of medical organizations and improves the general capacity of the veterinary hospital.
    2).The machine can reduce the labor of the anesthesiologist.
    3).The machine is easily operated, which will reduce risks.
    4).It is easy for the doctor to control the machine.
    5).The circle and compact working mode will reduce the contamination of operating rooms.

    II. The advantages of RE902-C(v) veterinary anesthesia machine:
    It is available for operating in different medical locations. The machine has four soft feet on the bottom to increase the stability of the machine.
    The construction is very compact and nice looking, which is ideal for small working spaces. The machine has a handle for moving around easily. The machine is very stable.
    Has special and compact CO2 circle absorber, it will supply the stable anesthesia gas and save the anesthesia gas usage and keep the operating room clean.
    Two tubes flowmeter, O2 and N2O,Adjust O2 and N2O in proportion(O2 concentration is not lower than 25%),The Min. scale is 100ml, The precision is high which is available for low flow anesthesia operation. At the same time, it can be used for reducing the pain function.
    The machine has O2 Flush function.,has special inspiration valve and expiration valve.
    Has APL valve, which will protect the patient from high pressure damage.
    The machine has built-in CO2 absorber, which has a window to check the sodalime situation. And it is easy for the doctor to change the sodalime.

    III. The technical specification of RE902-C(v)veterinary anesthesia machine:

    1).Ventilation method:closed, half-closed,half-open
    2).Tidal volume( Manual Mode):20ml-1500ml
    3). Work pressure:0.3---0.4Mpa
    4).Flow meter:   O2:0.1---10l/min    N2O: 0.1---10l/min
    5).APL valve:0.5---6.0Kpa
    6).O2 Flush:30-60L/min
     
     


    Company: Beijing Read Eagle Technology Co.,Ltd
  • Portable Veterinary Anesthesia Machine

    It is the newest and improved model of veterinary anesthesia machines,certificated with CE,ISO,TVU。
    It comes with a vaporizer of your choice: Isoflurane ,sevoflurane.Enflurane,Halothane
    I. RE902-C(v) veterinary anesthesia machine introduction
    RE902-C(v) veterinary anesthesia machine( circle and compact ) has full anaesthesia function. It is very small and portable. Inside there is a compact and built-in CO2 circle absorber system.
    The tidal volume of RE902-C(v) veterinary anesthesia machine is from 20ml to 1500ml, which can be used for 1kg animal to 100kg animals. It can be used universally at veterinary hospitals, animal labs and animal research institutes, and especially outside of the clinic while working with animals.
    RE902-C(v) veterinary anesthesia machine has many advantages for the anesthesiologist and anesthesia operation projects:
    1).The machine improves the medical equipment level of medical organizations and improves the general capacity of the veterinary hospital.
    2).The machine can reduce the labor of the anesthesiologist.
    3).The machine is easily operated, which will reduce risks.
    4).It is easy for the doctor to control the machine.
    5).The circle and compact working mode will reduce the contamination of operating rooms.

    II. The advantages of RE902-C(v) veterinary anesthesia machine:
    It is available for operating in different medical locations. The machine has four soft feet on the bottom to increase the stability of the machine.
    The construction is very compact and nice looking, which is ideal for small working spaces. The machine has a handle for moving around easily. The machine is very stable.
    Has special and compact CO2 circle absorber, it will supply the stable anesthesia gas and save the anesthesia gas usage and keep the operating room clean.
    Two tubes flowmeter, O2 and N2O,Adjust O2 and N2O in proportion(O2 concentration is not lower than 25%),The Min. scale is 100ml, The precision is high which is available for low flow anesthesia operation. At the same time, it can be used for reducing the pain function.
    The machine has O2 Flush function.,has special inspiration valve and expiration valve.
    Has APL valve, which will protect the patient from high pressure damage.
    The machine has built-in CO2 absorber, which has a window to check the sodalime situation. And it is easy for the doctor to change the sodalime.

    III. The technical specification of RE902-C(v)veterinary anesthesia machine:

    1).Ventilation method:closed, half-closed,half-open
    2).Tidal volume( Manual Mode):20ml-1500ml
    3). Work pressure:0.3---0.4Mpa
    4).Flow meter:   O2:0.1---10l/min    N2O: 0.1---10l/min
    5).APL valve:0.5---6.0Kpa
    6).O2 Flush:30-60L/min
     
     


    Company: Beijing Read Eagle Technology Co.,Ltd
  • TKR-200 High-Frequency Jet Ventilaotr
    A kind of opening high and normal-frequency jet ventilator with pressure regulating and time circle form. Its principle is: under the airway opening state, using high pressure gas power (O2 or compressive air) and high gas flow, rhythmically jet gas into airway through an electronic automatically controlled route, to expand the long for gas exchange.
     
    Feature:
    A. Two ventilation modes: High-Frequency Jet Ventilation (HFJV) and Continuous Positive Airway Pressure (CPAP).
    B. ABS engineering plastic cabinet and good looking PVC panel.
    C. Multiform ventilation modes and alarm function, its convenient operation is suitable for medium or minitype hospital and rural hospital.

    Specifications:
    Frequency: 8
    150 breaths/min
    I/E ratio: 1:1
    1:3 and inverse ratio
    Driving Pressure: 0
    0.30MPa
    CPAP: 0.1
    0.8 KPa
    Maximum Oxygen Concentration: 85%
    Alarm: Alarm with light and sound when no power and it will last more than 120 seconds; or alarm when no oxygen for 6 seconds.
    Humidifying Rate: 015ml/h
    Pressure Regulator Limit: 0.35MPa
    Ventilation Modes: HFJV (High Frequency Jet Ventilation); CPAP (Continuous positive airway pressure),Manual ventilation.


    Company:  Jiangxi TELI Anaesthesia & Respiration Equipment Co., Ltd.