  • Hematology Analyzer
    Test Items: 18 parameters: RBC, HGB, WBC, LY#, MO#,
    GR#, LY%, MO%, GR%, HCT, MCV, MCH,
    MCHC, RDW, PLT, MPV, PCT, PDW
    Linearity Range: RBC: 1.00~9.99*1012/L
    HGB: 20g/L~200g/L
    WBC: 0.50~99.0*109/L
    PLT: 50~999*109/L
    Precision (CV): RBC: ≤2.5%
    HGB: ≤1.5%
    WBC: ≤3.5%
    LY%: ≤6%
    MO%: ≤12%
    GR%: ≤6%
    MCV: ≤2%
    PLT: ≤5%
    MPV: ≤3%
    Dilution Ratio: WBC / HGB 1: 500
    RBC / PLT 1: 50000
    Sample volume: Periphery/whole blood: 20μl

    Company: Shenzhen Yidatai Co., Ltd.
  • Urine Analyzer
     Parameters: PH, Nitrite, Ascorbic Acid, Protein, Specific Gravity, Blood, Bilirubin, Urobilinogen, Ketone, Leucocytes, Calcium, Creatinine, Microalbumin
    Principle: Dual-wavelength reflectance photometry
    Wavelength: 550nm, 620nm, 720nm
    Throughput: 420 samples/hour
    Memory capacity: 1000 results
    Strip: Uritest 10G\11G\13G urine reagent strips

    Features:
    Easy maintenance design for daily cleaning
    High test speed, up to 420 tests per hour, ideal for extensive sample laboratory
    Fully automatic operation for ready-to-test
    Internal calibration for sensitivity of strips
    Cold light source facility with long life and high stability
    Barcode reader & touch screen optional
    URIT UQ-10 & UQ-11 Urinalysis Control

    Company: URIT Medical Electronic Co., Ltd
  • Urine Analyzer
    * Test items: pH, Nitrite, Specific gravity, Ascorbic Acid, Blood, Glucose, Bilirubin, Urobilinogen, Ketone, Leucocytes, Protein.
    * Principle: Spherical integrator and dual-wavelength reflectance photometer.
    * Two test modes: Normal mode, 60samples/hour,
    Continuous mode, 120samples/hour.
    *Memory capacity: 1000 samples.
    *Strip: Uritest 10A/11A/13G urine reagent strip
    * Dimension: 290mm x 200mm x 100mm
    Characteristics:
    *Low cost, smaller volume, easy to use
    *Cold light source, less interference and long life
    *Uritest series urine reagent strips for your selection
    *Internal thermal printer and external printer applicable.
    *Standard RS232 interfacing to host computer.
    *Barcode reader applicable

    Company: URIT Medical Electronic Co., Ltd
  • Urine Analyzer
     Uritest series of urine reagent strip for your free selection.
    The addition Ascorbic Acid item increase the reliability of the measurement.
    Internal graphic thermal printer with character of low noise, high speed and long service life. That is more than 50, 000 samples. Outer printers are also supported.
    Larger LCD screen, in-built microcomputer, allow more function menus
    RS232 interface, interfacing to the computer is convenient.
    Automatically remove the waste reagent strip.
    On-line software is available.

    Company: URIT Medical Electronic Co., Ltd
  • Urine Analyzer

     Uritest series of urine reagent strip for your free selection
    The addition Ascorbic Acid item increase the reliability of the measurement

    Internal graphic thermal printer with character of low noise, high speed and long service life. That is more than 50, 000 samples. Outer printers are also supported.

    LCD screen, microcomputer
    RS232 interface, interfacing to the computer is convenient

    Automatically remove the waste reagent strip
    On-line software is available
    Maybe the cheapest urine anylyzer who has the self-motion removing reagent strips function.


    Company: URIT Medical Electronic Co., Ltd
  • Urine Analyzer

     ·Uritest series of urine reagent strip for your free selection

    ·The addition Ascorbic Acid item increase the reliability of the measurement
    ·Low noise and long life thermal printer

    ·Touch LCD screen, microcomputer
    ·RS232 interface and printer interface connect with computer and out printer

    ·remove the waste reagent strip
    ·On-line software is available


    Company: URIT Medical Electronic Co., Ltd
  • Biochemistry Analyzer

     Features
    Free choice for reagent
    Grating as dispersive element
    10.4 color LCD in English

    Main specifications
    Light source: Halogen-tungsten lamp (12 V/30W)
    Wavelength range(nm): 330---800nm (continuous adjustment)
    Spectrum band: ≤6nm
    Absorbency range: -0.3Abs---3.0Abs
    Temperature control: Room temperature or 25 or 30 or 37
    Sample-volume: 100ul--2000ul
    Testing method:
    A) Linear end point
    B) Non-linear end point (standard curve)
    C) Two-points (time fixing)
    D) Kinetics
    E) Single and double wavelength
    F) Absorbency
    G) Blank sample
    Fixedly store 67 items, up to 200 item parameter
    Printer: Built-in thermal printer; Paper width: 110mm
    Cuvette: Flowing; 10mm; 32ul
    Standard RS-232 interface
    Power supply: 220V± 15%, 50Hz ± 2%


    Company: Tsingtao Unicom-Optics Instruments Co., Ltd.
  • Biochemistry Analyzer

    Specifications for Biochemistry Analyzer (2280):
    Optics:  8 fixed interference filters (340, 380, 405, 492, 510, 546, 578, 630nm)
    Light source: Long life halogen lamp, 12V, 20W
    Reading cell: A continuous flow-cell: Internal volume 33 ul, usual reading volume 500 ul. Peltier effect temperature control: 37º C± 0.1º .
    Reagent capacity: Three reagent disks, each disk can hold 17 different reagents, 51 reagents supported totally.

    Sample & reaction plate: Round rotating plate, with 45 positions for sample or standard cups. 37º C thermostat controlled. 4 replaceable multi-cell sectors (24 cells each). 96 reaction cells totally.
    Zeroing: Automatic
    Calibration: Automatic; 1-45 (optional) or standard protein-based calibration solution
    Range of absorbency: 0 - 2.5 Abs
    Linearity: <1%
    CV: <1%
    Power supply: 220V, 50Hz (optional 115V, 60Hz)
    Power: 140W
    External Interface: Two-way RS-232
    Dimensions: 370x650x670mm
    Weight: 38Kg
    Printer: 24 pin stylus printer, inkjet printer or laser printe


    Company: Tsingtao Unicom-Optics Instruments Co., Ltd.
  • Biochemistry Analyzer
     Light source: Halogen-tungsten lamp (12 V/30W)
    Wavelength range (nm): 330---800nm
    Spectrum band: ≤6nm
    Absorbency range: -0.3Abs-3.0Abs
    Sample volume: 100ul-2000ul
    Testing method:
    A) Linear end point
    B) Non-linear end point (standard curve)
    C) Two-points (time-fixed method)
    D) Kinetics
    E) Double wavelength
    F) Absorbency
    G) Sample blank
    Item storage: More than 200 item parameters
    Printer: Built-in thermal printer (cab be connected to outer printer)
    Sample dosage: 1-50ul (according to demand of the reagent)
    Cuvette: Flowing, 32ul, 10mm
    Interface: RS-232
    Power supply: 220V± 10%, 50Hz

    Company: Tsingtao Unicom-Optics Instruments Co., Ltd.
  • Semiautomatic Biochemistry Analyzer
     Light source: Halogen-tungsten lamp (12 V/30W)
    Wavelength range (nm): 330---800nm (continuous adjustment)
    Spectrum band: ≤6nm
    Absorbency range: -0.3Abs-3.0Abs
    Temperature control: Room temperature or 25º C 30º C or 37º C
    Sample volume: 100ul-2000ul
    Testing method:
    A) Linear end point
    B) Non-linear end point (standard curve)
    C) Two-points (time fixing)
    D) Kinetics
    E) Single and double wavelength
    F) Absorbency
    G) Blank sample
    Fixedly Store 67 items, up to 200 item parameters
    Display: 240 x 128 LCD
    Printer: Built-in thermal printer; Paper width: 110mm
    Cuvette: Flowing, 32ul, 10mm
    Standard RS-232 interface
    Power supply: 220V± 15%, 50Hz ± 2%

    Company: Tsingtao Unicom-Optics Instruments Co., Ltd.
Select to
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.
Page 3 of 18    3 ......
Go to Page