  • Protable Patient Monitor(ET-400A)
    Flexible (0-90degree)12.1 inch high resolution(1024 * 768) colorful TFT LCD
    Simultaneous display of 7 lead ECG in one frame
    Analysis of real times ST segment and arrhythmia
    Standard parameter of 7 lead ECG , NIBP , RESP , digital SPO2 , TEM and PR with optional configuration IBP , ECTO2,built in printer , drug does calculation and OXYCRG
    Maximum 120 hour graphic and tabular trend with data storage
    Networking capacity of maximum 66 beds and compatibility with HIS
    Digital SPO2 enables effective examination in case of active patient and low infusion as well interference caused by electric knife
    Compact and portable design allows uninterrupted with its built in rechargeable battery
     
    Standard Accessory
    5 lead ECG cable     1pc
    NIBP tube and cuff          1pc
    Temp probe                  1pc
    Digital SPO2 probe          1pc
    ECG electrodes               10pcs
    Built in rechargeable battery   1pc
    Power cable                   1pc
    Grounding cable          1pc
    Fuse                          2pcs


    Company: Etai Medical Co.,Ltd.
  • Portable Patient Monitor(ET-7000C)

    Description
    10.4TFT display
    Easy to carry, built-in battery, uninterrupted monitoring from external AC power to internal battery
    Operated by icon indication button and rolling mouse
    Full-Lead ECG monitoring, optional ST segment analysis
    Resist the electrosurgical interference and defibrillation
    Built-in interconnection function, able to realize central monitoring
    Built-in thermal printer to record the monitoring results
    Review and record the tendency chart info of the 48-hour monitoring parameters
    Standard Configuration
    Full-lead ECG, NIBP, ASpO2 (anti-motion oximetry), Pulse, Temp and RESP




    Company: Etai Medical Co.,Ltd.
  • Handheld Multi-para.Monitor(ET-I)
    Parameters:
    Five Parameters: ECG, NIBP, Pulse Rate, TEMP, SPO2.
    Waveforms:
    Two Waveforms: ECG waveform, SPO2 waveform (PLETH).
    Features:
    1.Handheld; Compact, light, easy for carrying and handling.
    2.Clear and bright LCD small screen real time display, Touch Screen.
    3.Can be display the data and the waveform in a screen, and also can be switch between ECG waveform and PLETH.
    4.English interface to simple read and handling.
    5.Build-in rechargeable Ni/MH battery, longtime operating time.
    6.Storage and review of patient trend data up to 36 hours which is never lost even when power is off.
    7.Audio and visual alarm.
    8.Battery capacity indicator.
    9.Automatic power-off.
    Standard accessories :
    one ECG cable with TEMP sensor
    one NIBP cuff with extend tube
    one SpO2 adult finger probe(soft)
    one charger
    one touch pen inside the model
    Technical Specifications
    ECG
    Input3-core ECG cable, standard AAMI cable connector
    Lead selectionI,II,III
    Gain selection:X1, X2, X4, X8
    Frequency response:
    None filter: 0.05100Hz (-3dB)
    filter: 0.540Hz (-3dB)
    Scan Speed: 12.5, 25, 50 mm/S
    ECG standard signal: 1mV square wave generated by hardware
    Heart rate
    Measure range: 20250 bpm
    Renew time: 1 time per beat
    Accuracy: 1 bpm
    Alarm limits range: Upper limits 80250bpm, Lower limits 40100 bpm
    Alarm mode: Audible and visual alarm
    NIBP
    Measure Method: Automatic oscillometric
    Average measure time: 40 seconds
    Repeat Cycles: 1, 2, 3, 5, 10, 15, 20, 30, 60 minutes
    Alarm limits range:
    SYS : Upper limits 120250 mmHg, Lower limits 60180 mmHg
    DIA : Upper limits 80150 mmHg, Lower limits 40120 mmHg
    MAP : Upper limits 100230 mmHg, Lower limits 50160 mmHg
    SpO2
    Measure Range: 35100%
    SpO2 Accuracy: 2%(7099%), 3%(4070%)
    Pulse Rate Range: 0254 bpm
    Pulse Rate Accuracy: 1 bpm

    Alarm limits range:
    SpO2 upper limits : 9599%
    lower limits: 8596%
    Pulse Ratekeep up with the heart rate

    Temperature
    Input : Apply the same sensor with ECG
    Measure range: 050
    Alarm limits range: Upper limits 3645 Lower limits 3438
    Measure accuracy: 0.1

    System specifications
    Alarm ON/OFF: controlled by general switch and parameter switch (two levels)
    Display mode: Homochromy LCD hand touch screen
    Waveform channel: Single channel
    Trend data: 36-hour HR, SpO2, TEMP,SYS, DIA, trend data.
    Dimensions: 114(D)X45(H)X150(W) mm


    Company: Etai Medical Co.,Ltd.
  • SPO2&TEMP Patient Monitor(ET-II+)
    Parameters
    Three ParametersSPO2TEMPPulse Rate.
    Waveforms
    Waveform: SPO2 waveform-PLETH
    Features
    1.Compact, small, light, easy for carrying and handling.
    2.LCD display of measurement and PLETH.
    3.Intelligent parameter monitoring interface.
    4.Audio and visual alarm.
    5.Storage and review of patients trend data up to 36 hours which is never lost even when powers off.
    6.Build-in rechargeable Ni/MH battery.
    7.Battery capacity indicator.
    8.Automatic power-off
    9.Patients trend can be transmitted to a personal computer for display, saving and printing.
    Color
    Blue or Pink can be selected.
    Standard accessories
    one SpO2 adult finger probe
    one TEMP skin face probe
    one charger
    one communication cable
    one software CD
    1. General
    Monitoring Parameters: SpO2PRPLETHPulse strengthTEMP
    Signal socketsSpO2 socketPR socketTEMP socketadaptor socketPC communication socket
    2. Display screen
    Type:128×64 dot matrix homochromy LCD
    Display area:45mm×30mm
    Backlight color: White
    LED:Dual-color LED (red/green)
    Size: 120mm×63mm×32mm
    Weight: 300gnot include probes and adaptor
    3. Features
    PLETH: The monitor can display PLETH waveform
    Intelligent parameter monitoring screen: The monitor automatically selects the parameter measurements to display according to the probes connected to the monitor.
    Audio and visual alarm: The speaker sounds the alarm and the parameters measurement flashes on the screen.
    Prompting: Icons of battery capacity, pulse sound switch and alarm sound switch.
    Power saving: The monitor will automatic shut down when no monitoring for 3 minutes.
    Trend: The monitor saves parameter measurements every 2 seconds and can store trend data up to 36 hours.
    Data storage: The saved data will never be lost even if the monitor is powered off.
    Communication: Transmitting the patients trend to a PC for display, observation, saving and printing.
    4. Electrical specifications
    Working Voltage: 6.0VD.C.9.0VD.C.
    AC power adaptor
    Input: 100-240VAC, 50/60Hz, 0.7A
    Output: 8V D.C., 800mA
    Internal battery
    Type: 2Ahr/6V Ni/MH rechargeable battery
    Run Time: 15-hour continuous operation with a new, fully charged battery (environment temperature is 25)
    Recharge time: 10 hours
    5. Environment
    Temperature
    Operation: 0°C ~ 45 °C
    Transportation and storage: -20°C ~ 60 °C
    Humidity
    Operation: 15% - 95 %( noncondensing)
    Transportation and storage: 10% - 95 % (noncondensing)
    Altitude
    Operation: 86 KPa ~106 KPa
    Transportation and storage: 50KPa~106 KPa
    6. Parameter Specifications
    SpO2
    Patient: Adult, child
    Range: 35% - 100%
    Resolution: 1 %
    Accuracy: 70% - 99%: ±2 %
    0% - 69%: Unspecified
    PR
    Range: 30 bpm ~250bpm
    Resolution: 1bpm
    Accuracy: ±2bpm
    TEMP
    Channel: 1
    Input: Body surface thermal-sensitive resistor temperature sensor
    Range: 050
    Resolution: 0.1
    Accuracy: ±0.2


    Company: Etai Medical Co.,Ltd.
  • SPO2&TEMP Patient Monitor(ET-II+AA)
    Parameters
    Three ParametersSPO2TEMPPulse Rate.
    Waveforms
    Waveform: SPO2 waveform-PLETH
    Features
    1.Compact, small, light, easy for carrying and handling.
    2.LCD display of measurement and PLETH.
    3.Intelligent parameter monitoring interface.
    4.Audio and visual alarm.
    5.Storage and review of patients trend data up to 36 hours which is never lost even when powers off.
    6.Common AA alkaline or rechargeable batteries to support 7 continuous working hours;
    7.Battery capacity indicator.
    8.Automatic power-off
    9.Patients trend can be transmitted to a personal computer for display, saving and printing.
    10.Suitable for adult, pediatric, infant and neonate patients.
    Standard accessories
    one SpO2 adult finger probe
    one TEMP Skin face probe
    one communication cable
    one software CD
    Specifications:
    Patient Range
    Adult, pediatric, infant, neonate patients
    Oxygen saturation (SpO2)
    SpO2
    Measurement range: 35%~100%
    Accuracy: ±2%(70%~100%) ,0%~69% unspecified
    Resolution: 1%
    Pulse Rate
    Measurement range:30 bpm -250 bpm
    Accuracy:±2bpm
    Resolution:1bpm
    Temperature (TEMP)
    Channel: 1
    Input: Body surface thermal-sensitive resistor temperature sensor
    Measurement range:0 oC50
    Accuracy:±0.2
    Resolution:0.1
    Alarm
    Mode:Audio and visual alarm
    Setup:User-adjustable high and Low limits
    Storage and Review
    36 hours SpO2 \PR\TEMP trend data with corresponding date and time
    Display Mode
    LCD screen:128×64 dot matrix homochromy LCD
    Measurements and information display
    LED indicator:Red and green Dual-color LED
    Red LED: insufficient battery power indicator
    Green LED: pulsating rhythm indicator.
    Operation Environment
    Temperature:
    Working:0 oC ~ 45oC
    Transport and storage:-20 oC ~ 60 oC
    Humidity:
    Working:15%~ 95%(non-condensing)
    Transport and storage:10 %~ 95%(non-condensing)
    Altitude:
    Working:86 kPa ~ 106 kPa
    Transport and storage:50 kPa ~ 106 kPa
    Power Requirements
    Battery type:common 1.5V AA alkaline or rechargeable batteries
    Run time:7 hours
    Dimension
    72 (W) ×130 (H) × 34 (D) mm



    Company: Etai Medical Co.,Ltd.
  • Multiparameter Monitors

    6.4" High Brightness TFT LCD (8.4",10.4" and 12.1")

    1-8 Channel Waveform Display
    7 Channel ECG Waveform Display; ST Segment
    Analysis; Arrhythmia Analysis
    Anti-movement and low perfusion SpO2 Measurement
    Pace Pulse Detection
    Defibrillation and ESU Protection
    OxyCRG diagram; Drug Dose Calculation
    Blood Dynamics Ananlysis
    Venous Punch
    Flexible Parameter Configuration


    Company: Nanjing Med-Vet International Trade Corp.
  • Monitor

    Monitor 

    Model:PA-500A


    Company: Perlong Medical Equipment Co.,Ltd.
  • Patient monitor

    Compact and portable, allowing for uninterrupted monitoring with built-in battery
    Display of NIBP, SpO2 and Pulse Rate via LED with high brightness
    3 configurations selectable
    Manual/auto/continuous measurement of NIBP
    Auto audible and visual alarms
    Storage of NIBP data up to 900 groups or SpO2 data up to 24 hours
    External printer available
    Applications from adults to neonates


    --------------------------------------------------------------------------------
    Standard Configuration:
    A. NIBP/PR
    B. NIBP(Nellcor Module)/PR
    C. SpO2(Nellcor Module)/PR
    Standard accessories: NIBP tube and Adult cuff, Adult reusable SPO2 sensor, Temp probe, Built-in rechargable battery.

    --------------------------------------------------------------------------------
    Option:
    External Termal Recorder

    --------------------------------------------------------------------------------
    Technical Specifications
    Dimension and Weight
    Dimension: 180 mm(W) X 60mm(H) X 220mm(D)
    Weight: 1.8kgs

    Operation Environment
    Power Requirements: AC 100-250V, 50/60 Hz

    Application Scope
    Adult, child and neonatal

    Performance Specifications
    Display: LED
    Battery: Rechargeable, lasting for maximum 2 hours
    NIBP
    Method: Oscillometric
    Operation modes: Manual/Automatic/Continuous
    Meausrement unit: mmHg/Kpa selectable
    Automatic measurement interval: 1,2,3,5,10,30,45,60,90,120,180,240,480 minutes
    Measurement Range:
    Adul/Pediatric: 15-255mmHg
    Neonate: 10-135mmHg
    Resolution: 1 mmHg
    Over-pressure protection: Adult/Pedicatric Mode 290mmHg
    Neonate: 145mmHg

    SpO2
    Measurement range: 0-100%
    Resolution: 1%
    Accuracy: ±1% (90-100%)
    ±2%(70-89%)
    Alarm range: 1-100%


    Pulse Rate
    Range: 0-254 bpm
    Resolution: 1bpm
    Accuracy: ±1bpm
    Alarm Range : 0-254bpm
    Package Information
    9200M5 without recorder
    Carton Dimension: 410 mm(L) X 290 mm(W) X 200 mm(H)
    Gross Weight: 3.3 kgs


    Company: AMBULANC(SHENZHENZ)TECH.CO.,LTD.
  • Multi-parameter Monitor
    Features:
    12.1 high-resolution TFT display, which can indicate waves of ECG, respiratory rate (RESP) and pulse in detail;
    20 methods of automatic arrhythmia analysis, ST segment analysis;
    Can recall lapsed ECG wave in 5 minutes, and the wave can be frozen;
    Complete ECG monitoring through selection by different leads positioning;
    Up to 96 hour tendency statistics of SpO2, pulse rate and non-invasive blood pressure;
    Data memory of up to about 10 groups of VPC events for review and analysis;
    Memory and view of a list ofup to 400 measures of non-invasive blood pressure, as well as heartrate, temperature, respiratory rate and SpO2/pulse rate when themeasure of blood pressure is taken;
    Unique SpO2 measuring device is used to ensure accuracy of the SpO2 and pulse rate measurements;
    Resistance against interference from defibrillator and electrosurgical knife. It may be used along with cardiac pacemaker;
    Blood pressure may be measuredin the mode of adult/infant/neonate, which may be selected via themenu, to better suit the neonate or infant or adult patient;
    Information like printer, output waveform and text may be set as necessary;
    The modular equipment designallows the user to choose different monitoring parameters and form amonitor according to users own need;
    It may be networked with the center as a part of the central network.

    ECG
    ECG lead: , , , AVR, AVL, AVF, V1V6, GND
    S-T segment analysis: -2.02.0mv
    Arrhythmia analysis: yes
    Protegtion: With stand 4000vAc/50Hz voltage in isolation and work against eletrosurgical interence and defibrillation

    Respiration
    Measurement method: Thoracic impedance

    NIBP
    Working mode: Manual/Automatic/stat(5 minutes)
    Method: Automatic oscillation
    Cufftype: standard Adult; optional Pediatric/Neonatal

    Temperature
    Measurement range 20~45
    Resolution 0.1
     
    Pulse Oximetry(spO2)
    Range: 0100% for adult,pediatric and neonatal patients optional Rectal/esophagea

     
    Pulse range
    Pulse range: 0-255bpm

    Company: YangZhou HongDu ELECTRONIC CO.,LTD
  • DJ-10 Ultra-thin Multiparameter Monitor

    DJ-10 Ultra-thin Multi-parameter Monitor
    12.1" TFT display screen with 5 waveforms
    The complete set is portable, suitable for monitoring patients in transfer.
    Can connect with central unit to form central monitor system
    Complete monitor parameters: ECG, Respiration, SPO2, NIBP, pulse, temperature, etc.
    Trend chart for 48 hours with all parameters and support playback of ECG.
    Sound and light alarm
    Built-in recorder and various record modes are available.

    Company: Chengdu Mechan Electronic Technology Co. LTD