Feature: A. Medical staffs can choose one among the three modes such as constant-time, constant-volume and constant-pressure according to the patients' condition or can circularly choose anyone among the three modes. B. Multiform respiratory modes can be chosen under the three switching modes, which can guarantee for clinical subtle respiratory treatment. C. Comprehensive setting and display of alarm value. D. Configured with exact adjustment system for respiratory gas-oxygen concentration, calculagraph and constant temperature humidifier for inspiration gas. E. Perfect computerized monitor for ventilating parameters and display for presetting number. Specifications: Frequency(IPPV):6~60 breaths/min I/E ratio:1 : 1~ 1 : 3 Tidal volume :100~1500ml /time Inspiration pause:O~0 .5s with five gears SIGH:Sigh is added once per 100 breaths of respiration and its volume is 1.5 times as much high as that of the ventilation. Synchronous sensitivity :-2~-0.1KPa PEEP/CPAP:O~2KPa Display of airway pressure:-2~6KPa Concentration of inspiration gas and oxygen:21%~100% adjustable Display of inspiration time:0.2~9.9s IPPV inspiration flux:0.1~1.5L/s Intermittent command ventilation frequency:1~15breaths/min Alarm for upper-limitation of airway pressure:1.0~6.0KPa Alarm for lower-limitation of airway pressure:0~2.0KPa Switching time between synchronization mode and control mode:6s Display of minute volume:0~30L Presetting inspiration pressure:0.1~3.5KPa Ventilation modes: Inspiration pause, CPAP, IPPV,IPPB,PEEP,SIMV, IPPV+SIGH, First-aid ventilation.
Physical Specifications of medical ventilator Dimensions Carrying packages Dimensions Packaging Dimensions Width: 300mm Width: 460mm Width: 620mm Depth: 160mm Depth: 200mm Depth: 240mm Height: 230mm Height: 400mm Height: 410mm Weight 3Kg Weight 7Kg Weight 11Kg
Environmental Specifications of medical ventilator Operating Requirements Storage/Shipping Requirements Temperature: 5 to 40°C Temperature: -20 to 70°C Relative Humidity: less than 80% Relative Humidity: less than 93% The atmosphere pressure: 70 to 106 kPa The atmosphere pressure: 70 to 106 kPa Electrical Specifications of medical ventilator Input Voltage Requirements AC Voltage: 110V~240V DC Voltage: 12V Inlet Battery:12V , 2Ah (Can be used for 8 hours) Frequency: 50Hz/60Hz Power: 2A Pneumatic Specifications of medical ventilator Pneumatic Specifications Oxygen Inlet Pressurized Oxygen: 0.4MPa medical oxygen or use 2L oxygen cylinder (Choice of suppliers)
Steel Oxygen Cylinders
Application Standard: GB5099; ISO9809; EN1964-1; JISB8241 Temperature Range: -40 ~ 65 oC Filling Medium: oxygen, high-purity oxygen Material: 37Mn; 34CrMo4; 34Mn2V