  • UV-Visible Spectrophotometer
    Spectrophotometer (UV-2900PC )
    All spectrophotometers feature high performance sealed optics mounted on a stable machined platform. All spectrophotometer are intended to be utilized for research, development, quality control, etc. primarily in the fields of optical materials, semiconductors, new materials, electronics and so on through qualitative and quantitative analyses of samples diverse in kind and size. The comprehensive features, optional sophisticated powerful software, variety of accessories and model configurations will meet or exceed your expectations for performance and value.

    The spectrophotometers perform built-in wavelength calibration program automatically after energization. Core components will be check during the initialization to ensure the wavelength accuracy and excellent performance

    Pre-aligned deuterium lamp and tungsten lamp for easy lamp replacement. The light source changing point can be set in range of 300nm - 400nm

    The innovative optical layout ensures accuracy. Its integrated design assures long-term stability and durability. The precisely aligned detector and quality deuterium and halogen lamps enhance the precision.
    Perform basic mode( Abs / %T), quantitative
    Pre-set wavelength program (4 wavelengths), and one-touch key response
    Single-point curve calibration and multi-point curve calibration (up to 12 points)
    Display of fitting degree of curve fitting and concentration data with up to 50 sets of curve parameters storage
    Display of concentration data with up to 200 sets of data storage
    Dark current calibration / wavelength calibration/System clock management
    Backup battery and integrated circuit design controlled by MCU assure non-volatile memory storage
    USB data communication
    LPT port for printing
    128*64 LCD screen to display all of the parameters
    Sealed and solvent-resistant tactile keypad

    Basic Mode

    Multi-Wavelength
    Absorbance, %T or Concentration measurements.
    Up to 15 wavelengths can be selected and multiple samples can be measured. (Auto cell changer is required to run multiple samples automatically).
    Quantitative (Standard Curve)
    Use up to 12 standards to establish standard curve.
    Four methods for fitting a curve:
    a. Linear fit
    b. Linear through zero
    c. Square fit
    d. Segmented

    Wavelength Scanning
    Interval: 0.1, 0.2, 0.5, 1, 2, 5 nm
    Automatically record peaks and valleys.
    Post-run manipulation and processing includes:
    a. Re-scaling axes, curve
    b. Smoothing, combination, zooming, overlap
    c. 1st to 3rd derivative

    Kinetics (Abs vs. Time)

    The Kinetics mode may be used for time course scanning or reaction rate calculations. Abs. vs. time graphs is displayed on the screen in real time. Wait time, measurement time and time intervals may be entered. Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor.

    DNA/Protein
    Concentration and DNA purity can be calculated quickly and easily: Absorbance ratios 230nm/260nm/280nm with optional subtracted absorbance at 320nm.
    Model
    UV-2900PC
    Monochromator
    C-T type, 1200 L/mm grating
    Detector
    Silicon detector for ultraviolet visible region
    Display
    128*64 LCD, Blue color
    Light source

    Deuterium discharge tube(2000h), Tungsten lamp(2000h, 20W/12V)
    Lamp change point
    Can be set, 300 nm - 400 nm
    Wavelength range
    190-1100 nm, autoscan
    Wavelength accuracy
    ±1.0 nm
    Wavelength calibration
    Automatic at start
    Wavelength display
    0.1 nm
    Slit width
    2 nm
    Wavelength repeatability
    0.5 nm
    Measurement range
    -1.0 ~ 200.0%T, -0.5 ~ 3.000Abs, 0 ~ 9999 C, 0 ~ 9999 F
    Photometric accuracy
    ±0.002 Abs (0 to 0.5Abs)
    Photometric repeatability
    ±0.001 Abs (0 to 0.5Abs)
    Stray light
    0.15 %T (at 220,360 nm)
    Baseline flatness
    ≤±0.004 Abs
    Stability
    ≤0.002 Abs / h (at 500 nm, after 2 hours energization)
    Data output
    Digital, USB port, LPT parallel
    Spectrum software
    Spectrum software, Windows® - based
    Power
    220V 10% 50Hz 70VA
    Standard sample holder
    4-position sample holder
    Actual dimensions
    456 W X 375 D X 220 H mm, (18.0 W x 14.8 D x 8.7 H in)
    Net weight
    14.5 Kg (32.0 lbs)
    Shipping dimensions
    19.5 Kg (43.0 lbs)


    Company: Tsingtao Unicom-Optics Instruments Co., Ltd.
  • Visible Spectrophotometer (1200RS)
    Visible Spectrophotometer (1200RS)
    Dynamic Range of 335-1000 nm.
    Controlled by built-in MCU, displays by two LED screens each with four digits. One displays wavelength value, the other displays transmittance, absorbance, factor and concentration value.
    Built-in RS232 digital output, with Specsoft application software based on Microsoft Windows, create working curve with three points used for calculating concentrations.
    Auto 0%(T)and 100%(T)function.
    Direct-reading concentration by setting concentration factor or setting reference concentration.
    Compact construction and modern design.
    1200RS VIS Spectrophotometer Performance Specification
    Spectral Bandwidth  5nm
    Monochromator
    Single beam, C-T type, grating 1200L/mm
    Wavelength Range      335nm - 1000nm
    Wavelength Accuracy±2nm
    Wavelength Repeatability 1nm
    Display Mode 
    LED displays T, A, F, C, λ
    Stray Light     ≤0.5%T(360nm)
    Photometric Accuracy  ±1.0%T
    Photometric Repeatability0.5%T
    Stability  ±0.004A/h, at 500nm
    T-A Transform Error  ≤±0.002A (at 0.5 A,≤±0.004A (at 1.0 A)
    Photometric Range:  0-199.9% T, 0.3-2.5 A, 1-9999 F, 0-9999 C
    Data Output 
    RS-232C, digital output,
    Sample Holder 
    10mm-50mm adjustable, four position
    Detector
    Silicon Photodiode
    Light Source     
    Tungsten lamp (socket type, 20W / 12V)
    Power Requirement   
    220V±10% 50Hz / 110V±10% 60Hz)
    Power Consumption      45W
    Application software   
    Specsoft application software
    Actual dimensions     
    385 W×310 D×190 H mm
    Shipping dimensions   
    456 W×378 D×262 H mm
    Net weight      ≤6.5Kg
    Shipping Weight  ≤8.0Kg