Medical Analyzer|Chemistry Analyzer|Urine Analyzer Manufacturers
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.
Select to
Page 2 of 18
  • Semi-automatic Biochemistry Analyzer

    Semi-automatic Biochemistry Analyzer

    Performance:
    1. Reasonable software, programmable biochemical test menu, 200 test programmes can be
       saved.
    2. 1000 patients test data can be saved.
    3. Clock CMOS chip inserted.
    4. Hermetic solid-state optical system, low contamination of dust and dampness,long life
       time of hard membrane filters.
    5. Back spectro photometry, 8 hard membrane filter, separate signal process circuit for
       each wavelength, filters select completed electronically,no mechanical movement.
    6. Titanium alloy flow cell with small capacity and minimize cross-contamination.
    7. Back-light LCD monitor and display character and curve simultaneously
    8. Self-test program, test error<1%, CV<3%

    Environment
    Temperature :0-40
    Humidity: 5-80%

    Technical feature:
    1.Analysis method: kinetics, end point, two point, etc.
    2.Power supply: 20w/12V halogen light, life time: 2000hr
    3.Optical system: 340-800nm, 8 hard membrane filter: 340, 380, 405, 492, 510, 546, 578,
      630nm(wavelength). Accuracy±2nm
    4.Abs range: -2.5002.5Abs, resolution:0.001Abs.
    5.Flow cell: titanium quartz alloy, 33uL; optical path: 10mm.
    6.Temperature: PELTIER elements, 25,30,37 0.1±
    7.Precision: error<1%, drift<5mAbs/hr
    8.200 test programmes can be saved
    9. 58mm thermal printer, no noise, high speed, easy maintenance.
    10.Keyboard: 24 keys touch keyboard
    11.Power supply: 220V±15%, 50Hz, 70VA
    12.Interface: standard RS232 serial interface
    13.Dimensions : 460(L)x380(W)x200(H)mm
    14.Weight: 13Kg(net), 15Kg(gross)



    Company: Nanjing Everich Medicare Import & Export Co.,Ltd
  • Automatic Electrolyte Analyzer

    Automatic electrolyte Analyzer
     The most advanced ionic selective electrode(ISE); Perform multiparameters as K+, Na+, Cl-,
    Ca++,PH etc. Adapt to all hospitals with different sizes

    Performance:
    1. More advanced ionic selective electrode (ISE),
       longer shelf-life
    2. Automatic time calibration, 24 hours power on, fitting for emergency treatment.
    3. reagent supplies with lower cost
    4. rapid and accurate test
    5. free maintenance

    Technical character:
    1.Assay method:  ionic selective electrode
    2.Assay time: 25 seconds(measure time) less than 48 seconds(the whole course,including
       sucking samples,reaction,washing and print)
    3.Sample volum: 120uL/70uL
    4.sample type: blood serum, blood plasm, whole blood, cerebrospinal fluit, diluted urine
    5.Data storage:  300 samples, Q.C. data for one month
    6. Display:240X64 back-illuminated liquid crysatl
    7. Printer:thermal printer,58mm paper width
    8. ISE life:more than 10 months
    9.Temperature/humidity0-40 /≤85%
    10.Power supply: AC 220V±20%  50Hz  30W
    11.Dimensions : 370(L)x280(W)x225(H)mm
    12.Weight: 7.5Kg(net), 8.5Kg(gross)


     



    Company: Nanjing Everich Medicare Import & Export Co.,Ltd
  • Urine Analyzer,KH-100 B09.01005

    KH-100 Urine Analyzer

     Performance:
    1.Super LCD monitor
    2.Adopt luminescence source with high brightness to minimize
       interference of the environmental light.
    3.The color and limpidness can be input
    4.Date and patient number can be input.
    5.Single test and continuous test are available
    6.The data can be saved automatically.

     Technical feature:
    1.Wave length: 510-650nm
    2.Throughput: 120 test/hr
    3.Storage: 1000 patient data
    4.Display: 240x64 LCD monitor
    5.Print: 57mm thermal printer
    6.InterfaceStandard RS232 serial interface
    7.Calibration: fully automatic calibration
    8.Condition: temperature: 15-35, humidity:10-85%
    9.Power supply: 220VAC±10%  50~60Hz  100W

     Test items:
    1.PH, Nitrite, Protein
    2.Glucose, occult blood, bilirubin
    3.Urobilinogen, ketone
    4.Specific gravity,Leukocytes
    5.Ascorbic Acid



    Company: Nanjing Everich Medicare Import & Export Co.,Ltd
  • Hematology Analyzer
    Test Items      WBC, LY#, MO#, GR#, LY%, MO%, GR%, HGB, RBC, HCT, MCV, MCH, MCHC, RDWCV, RDWSD, PLT, PCT, MPV, PDW, WBC Histogram, RBC Histogram, PLT Histogram
    Performance Index     Test Item     Linearity Range     Precision
    WBC(×109/L)     0.0-99.9     CV≤2% (4.0-10.0×109/L)
    RBC (×1012/L)     0.00-9.99     CV≤1.5% (2-6.0×1012/L)
    HGB (g/L)     20-200     SD≤3g/L (30-100)g/L CV≤1.5% (101-200)g/L
    MCV (fL)     40.0-150     CV≤0.5% (80.0-100fL)
    PLT (×109/L)     0.0-999     CV≤4.0% (100-500×109/L)
    Repeatability     Test Item     CV(%)     Test Range
    WBC     ≤2     4.0∼10.0×109/L
    RBC     ≤1.5     3.5∼6.0×1012/L
    HGB     SD≤3g/L
    CV≤1.5%
    (101-200)g/L     30∼100g/L 101∼200g/L
    PLT     ≤4     100∼300×109/L
    MCV     ≤0.5     80∼110fL
    Sample Volume     Twig blood: 20μl
    Dilution Ratio     WBC/HGB: 1:500RBC/PLT: 1:50000
    Interfaces     RS232 joint
    Continuous Work Time     >8h

    Company: Perlong Medical Equipment Co.,Ltd.
  • Semi-automatic Animal Hematology Analyzer
    Test Items : RBCHGBMCVHCTRDW(CV)MCH
    MCHCWBCLY#MO#GR#LY%
    MO%GR%Provide RBCand  WBC
    distribution histogram
    Linearity Range : RBC: 0.00~9.99×1012/L
    HGB: 20g/L~200g/L
    WBC: 0.00~99.9×109/L
    Precision (CV) : RBC: ≤2.5%
    HGB: ≤1.5%
    WBC: ≤3.5%
    MCV: ≤2.0%
    Testing Principles : Blood corpusclecount-impedance
    HGB-540nm wavelength colorimetry
    Display method : Liquid Crystal Display(LCD) shows testing
    parameters and square charts of RBC and
    WBC
    Sample Volume : Periphery blood: 20μl
    Measuring Time : ≤40s
    Data interface : RS232 serial port
    Packing Details:  460mm×420mm×520mm
    N.W.18kgs   G.W. 22kgs

    Company: Perlong Medical Equipment Co.,Ltd.
  • Uritest 300 Urine Analyzer
     Uritest series of urine reagent strip for your free selection
    The addition Ascorbic Acid item increase the reliability of the measurement
    Low noise and long life thermal printer
    LCD screen, microcomputer
    RS232 interface, interfacing to the computer is convenient
    Automatically remove the waste reagent strip
    On-line software is available

    Company: Guangzhou Yueshen Import & Export Co., Ltd
  • Semi-Auto Chemistry Analyzer
    Method: Kinetic, End-point, Linearity end-point, Non-linearity end-point, Absorbency,
    Sample blank, Multi-standards, Velocity, Calculation, Two-point, Double wavelength
    etc.
    7 wavelengths optic system avoiding outer disturbance, Wavelength range: 340nm-700nm;
    Quality control: Quality control for all tests, Statistic and print quality control
    parameters automatically with QC curves;
    Every test can do high.medium.low three groups quality control;
    Program: Add or delete test items easily according to the condition, modify the test
    parameters;
    Display Dynamic curves at real time, visually react the process;
    The print content includes comprehensive hospital's name and sample's materials;
    Dormant automatically for the lamp to prolong it's lifespan;
    Input 8 standard curves at most in testing with multi-standard method;
    The reagent is open;

    Company: Guangzhou Yueshen Import & Export Co., Ltd
  • Hematology Analyzer
     1) Function: just use 9.6μL of sample, really implement the micro-counting, not
    need pre-dilution outside the machine
    2) Advanced technology of back flush and refluence, keep away from clog. Automatic
    sample probe cleaning (inside and outside), without paper wipe. Automatic pipeline
    soak with operating the shut-down procedure, removing the protein adhering the
    counting aperture
    3) Fully closed reagent, reduce the pollution of reagent. Auto-lever detection, caution
    for change
    4) Detection parameter:
    a) White blood cell count (WBC)
    b) Lymphocyte number (LYM#)
    c) Mid-cell number (MID#)
    d) Granulocyte number (GRAN#)
    e) Lymphocyte percent (LYM)%
    f) Mid-cell percent (MID)%
    g) Granulocytes percent (GRAN)%
    h) Red blood cell count (RBC)
    5) Technical specifications:
    a) Detection principle: electrical resistance for cell counting, cyanide-free
    photometric method for HGB
    b) Detection parameter: 3-part differentiation of WBC, 20 parameters
    c) Work mode: double channels counting and independent hemoglobin
    blood detect system
    d) Volume of sample: 9.6μL
    e) Micro-aperture: WBC: 100μm; RBC/PLT: 80μm
    f) Throughput: >60 samples/hour, can run round-the-clock,
    automatic stand-by and active
    g) Classifying method: fixed terminus, float terminus, artificial adjustment
    h) Volume of reagent:
    ¢¡) Diluent: 20ml/sample
    ¢¢) Lyse: 0.3ml/sample
    ¢£) Cleaner: 4ml/sample
    ¢¤) Carryover: WBC, PLT, HGB<2%, RBC<1%
    6) Quality control: L-J QC diagram, -x, SD, CV%
    7) Result storage: automatic storing of all 12,000 sample parameters +3 histograms
    8) Reference value defining: adult man, adult woman, child, infant, common, and 3
    kinds of user self-defining
    9) Display: color LCD display with 10.4", resolution: 640 x 480
    10) Information: including many kinds of information such as: name, department,
    and inspector
    11) Input/output: parallel printer interface, RS232, keyboard interface,
    mouse interface
    12) Operation environment:
    a) Temperature: 15 - 35°C
    b) Humidity: 10 - 90%
    c) Power requirement: AC220V+10%, 50/60+1Hz or AC110V+10%, 50/60+1Hz
    d) Weight: 25kg
    13) PE-6000 Reagent List:
    Hemoglobin (HGB)
    Hematocrit (HCT)
    Mean cell volume (MCV)
    Mean corpuscular hemoglobin (MCH)
    Mean corpuscular hemoglobin concentration (MCHC)
    Red blood cell distributed width- standard deviation (RDW £­ SD)
    Red blood cell distributed width- coefficient of variation (RDW £­ CV)
    Platelet count (PLT)
    Mean platelet volume (MPV)
    Platelet distributed width (PDW)
    Plateletcrit (PCT)
    Plateletcrit-large cell ratio (P£­LCR)
    colorized volume distribution histogram of WBC (WBC Histogram)
    colorized volume distribution histogram of RBC (RBC Histogram)
    colorized volume distribution histogram of PLT (PLT Histogram)

    Company: Guangzhou Yueshen Import & Export Co., Ltd
  • Automatic Chemistry Analyzer
     Operating mode: Selective random access
    Assay methods: Kinetic, end pointer, fixed time, none linear, sample blank, reagent blank, direct absorbance
    Test modes: Routine, batch, STAT, profiles
    Available on-line item: 17 mono or double reagent
    Momorizable items: 51 mono or double reagent
    Testing speed: 100 test/hour with end pointer assay method
    Test repetition: Automatic on command
    Calibration and controls: Automatic on command
    Sample plate capacity: 45 position for sera, STD and Controls
    Sample volume: From 5 to 200ul, with 1ul increment
    Reagent volume: From 300 to 900ul, with 1ul increment
    Optical system: Colorimetric
    Light source: Long life halogen lamp, 12V, 20W
    Detectors: 8 silicon photodiodes UV/VIS
    Filter wavelength: 340-380-405-492-510-546-578-630nm
    Light path: 10mm
    Photometric linearity: From 0 to 2.500 Abs
    Photometric sensitivity: 0.001Abs
    Reading cell: Continuous flow-cell. 33ul
    Interface  Interface RS232 serial port
    Ambient temperature: 18 to 35TEMP.
    Incubation temperature: 37TEMP.
    Mains voltage: 220V, 50Hz (optional 115V, 60Hz)
    Power: 140W
    Dimensions: 370*650*670mm
    Weight: 38Kg
    Computer: Personal desktop computer (17'' monitor)
    Operating system:  Windows XP (2000, 2003, Vista)
    Printer:  24 pin stylus printer or inkjet printer or laser printer

    Company: Shenzhen Yidatai Co., Ltd.
  • Chemistry Analyzer

     Imported concave grating is used, the optical function is higher than plane, adjustable wavelength and there is no trouble to change the ray filter.
    Micro-computer control, big LCD display, English menu
    The general report of any item or sample, the English printing of quality control report and pictures item parameter.
    200 biochemical items stored inside, The program is open, the regent is arbitrary

    Main technological parameter:
    The wavelength range: 330-800nm, the wavelength is adjustable.
    Absorbance range: -0.3-3.0 Abs
    Cross contamination: <1%
    Perature control: 25TEMP, 30TEMP, 37TEMP, room temperature
    Printer: It is stored wind line high-speed thermal printer,
    It can print 6. English style report forms. It can check and judge the result.
    Standard connection: Standard RS-232C


    Company: Shenzhen Yidatai Co., Ltd.
Select to
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.
Page 2 of 18    2 ......
Go to Page