First Aid Kit|China First Aid Kit|First Aid Kit Products Manufacturers
| Add to Favorites
Search:
Here you will find Business Opportunity from Global Exporters, Suppliers, Manufacturers and Distributors.
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.
Select to
Page 10 of 11
  • Aluminum Alloy Foldaway Stretcher

    Technical Parameters:
    Product Size (L*W*H):1850*480*30mm
    Folded Size (L*W*H):460*480*130mm
    Carton Size (1pc): 960*530*160mm
    Load Limit: 159kg
    N.W.:7kg G.W.: 8kg


    Company: Yongfa medical equipment company
  • Autoclave Aerated Concrete Plant/Aerated Concrete Equipment/Autoclave Aerated Concrete Blocks Production Line
       From this page, you can get the Stone Crusher,Impact Crusher,Autoclave Aerated Concrete Blocks Production Line,Autoclave Aerated Concrete Blocks Equipment,ball mill,Mineral Processing. if you are interested in our products,please contact us by E-mail(sales@jxjq.com) or telphone, thank you.
      We are most professional manufacturer of autoclaved aerated concrete (AAC) plants and we can supply complete set of autoclaved aerated concrete plant with annual capacity from 50000 m3 to 300000 m3 and also the plant design, equipments installation, technical instruction and personal training, etc. We can also design and manufacture as per clients' requirement.
      Raw material: Cement, Lime, Sand, Gypsum, Aluminum powder, Water.
      

    Company: Shanghai Minggong Heavy Equipment Co., Ltd
  • Autoclave Aerated Concrete Plant/Aerated Concrete Equipment/Autoclave Aerated Concrete Blocks Production Line
       From this page, you can get the Stone Crusher,Impact Crusher,Autoclave Aerated Concrete Blocks Production Line,Autoclave Aerated Concrete Blocks Equipment,ball mill,Mineral Processing. if you are interested in our products,please contact us by E-mail(sales@jxjq.com) or telphone, thank you.
      We are most professional manufacturer of autoclaved aerated concrete (AAC) plants and we can supply complete set of autoclaved aerated concrete plant with annual capacity from 50000 m3 to 300000 m3 and also the plant design, equipments installation, technical instruction and personal training, etc. We can also design and manufacture as per clients' requirement.
      Raw material: Cement, Lime, Sand, Gypsum, Aluminum powder, Water.
      

    Company: Shanghai Minggong Heavy Equipment Co., Ltd
  • One step test for CK-MB/cTnI/Myo (Colloidal Gold)

    Intended Use: 
    One Step Test for CK-MB/cTnI/Myo(Colloidal Gold)applies colloidal gold immunochromatography 
    to detect CK-MB/cTnI/Myo in serum and plasma samples semi-quantitatively or 
    quantitatively. 


    Application Field:
    The Emergency Department, the Laboratory Department, the Internal Cardiology 
    Department, 

    the Department of Cardiac Surgery, the community medical institution, and 
    on-site emergency 

    treatment;Providing a fast bedside diagnosis for the patient.

    Principle of the Procedure: 
    Two kinds of high specific and sensitive cTnI/CKMBMyo monoclonal antibodies 
    are used for the test 

    strips. One is gold labelled and coated on the polyester film, and the other is fixed 
    on the test lines. 

    The antibodies on the test lines form sandwich complexes with any 
    CK-MB/cTnI/Myo in the blood 

    sample.The sample passes through the detection zone, in which the sandwich 
    complexes gather 

    along a line, appearing as a purplish red streak (the test or signal line). 
    Excess gold-labelled 

    antibodies gather along the control line, signaling visually that the test is valid.
    The intensity of the 

    test line increases in proportion to the CK-MB/cTnI/Myo concentration. 


    Company: Nanjing Perlove Medical equipment Co.,Ltd.
  • One step test for NT-proBNP/cTnI (Colloidal Gold)

    One step test for NT-proBNP/cTnI (Colloidal Gold)

    Intended Use:
    One Step Test for NT-proBNP/cTnI(Colloidal Gold) applies colloidal gold 
    immunochromatography to detect N-terminal B-type natriuretic peptide 
    precursor/cardiac Troponin I(NT-proBNP/cTnI)in serum and plasma samples semi -quantitatively or quantitatively. 
    The combined detection of NT-proBNP/cTnI can help doctors diagnose, 
    prognose and grade Heart Failure and Acute Coronary Syndrome more thoroughly.


    Principle of the Procedure:
    Two high specific and sensitive anti-human cardiac Troponin I monoclonal anti 
    bodies, one high specific and sensitive NT-proBNP monoclonal antibody and one 
    NT-proBNP polyclonal antibody are used for the test strips. Among other things, 
    one cTnI monoclonal antibody and the NT-proBNP monoclonal antibody are 
    biotinylated, gold-l abelled and coated on the polyester film, the other cTnI 
    monoclonal antibody and the NT-proBNP polycolonal antibody are fixed on the 
    test lines of the product.The antibodies form sandwich complexes with any 
    NT-proBNP/cTnI in the blood sample.The sample passes through the detection 
    zone,in which the sandwich complexes gather along a line, appearing as a purplish red streak(the test or signal l ine). Excess gold-labelled antibodies gather along the 
    control line, signaling visually that the test is valid.The intensity of the test line 
    increases in proportion to the NT-proBNP/cTnI concentration.

    Warnings and Precautions:
    1. Use for in vitro diagnostics.
    2. Use by healthcare professionals.
    3. The best testing temperature is 15~30℃, and the best humidity is 40~60%.
    4. Do not use the stri p beyond the expiration date printed on the outside of the box.
    5. The strip must be used within 1 hour once its foil pouch has been opened.
    6. The transfer pipette shoul d be used for one specimen only. Discard it after used.
    7. Patient specimens, used strip and transfer pipettes may be potentially infectious.
     Proper handling and disposal methods should be established by the laboratory 
    direction in accordance with local regulations.

    8. Proper laboratory safety techniques should be followed at all times when 
    working with potentially infectious blood specimens.


    Company: Nanjing Perlove Medical equipment Co.,Ltd.
  • One step test for NT-proBNP (Colloidal Gold)

    One step test for NT-proBNP (Colloidal Gold)

    Intended Use:
    One Step Test for NT-proBNP(Colloidal Gold) applies colloidal gold 
    immunochromatography to detect NT-proBNP in serumand plasma samples 
    semi-quantitatively or quantitatively.

    Principle of the Procedure:
    One high specific and sensitive NT-proBNP monoclonal antibody and one 
    NT-proBNP polyclonal antibody are used for the test strips. The monoclonal 
    antibody is biotinylated, gold-labelled and coated on the polyester film, and 
    the polyclonal antibody is fixed on the test lines. The antibodies on the test 
    lines form sandwich complexes with any NT-proBNP in the blood sample. 
    The sample passes through the detection zone, in which the sandwich complexes
     gather along a line,

    appearing as a purplish red streak (the test or signal line). Excess gold-labelled 
    antibodies gather along the control line,signaling visually that the test is valid.The 
    intensity of the test line increases in proportion to the NT-proBNP concentration.

    Warnings and Precautions:
    1. Use for in vitro diagnostics.
    2. Use by healthcare professionals.
    3. The best testing temperature is 15~30 ℃, and the best humidity is 40~60%.
    4. Do not use the strip beyond the expiration date printed on the outside of the box.
    5. The strip must be used within 1 hour once its foil pouch has been opened.
    6. The transfer pipette should be used for one specimen only. Discard it after used.
    7. Patient specimens, used strip and transfer pipettes may be potentially infectious. 
    Proper handling and disposal methods should be established by the laboratory 
    direction in accordance with local regulations.

    8. Proper laboratory safety techniques should be followed at all times when 
    working with potentially infectious blood specimens.


    Company: Nanjing Perlove Medical equipment Co.,Ltd.
  • One step test for hs-CRP (Colloidal Gold)

    One step test for hs-CRP (Colloidal Gold)

    Intended Use
    One Step Test for hs-CRP(Colloidal Gold) applies colloidal gold 
    immunochromatography to detect

    high-sensitivity C-reactive protein(hs-CRP)in serum,plasma and whole blood samples
    semi-quantitatively or quantitatively.This test supports the detection of mild or early
     forms of
    cardiovascular disease.


    Principle of the Procedure:
    Two kinds of high specific and sensitive anti-human hs-CRP monoclonal 
    antibodies are used for the test strips. One is gold-labelled and coated on the 
    polyester film,and the other is fixed on the test line of the product.The antibodies 
    form sandwich complexes with any hs-CRP in the blood sample. The sample 
    passes through the detection zone, in which the hs-CRP sandwich complexes 
    gather along a line,appearing as a purplish red streak(the test or signal line).Excess
    gold-l abelled
    antibodies gather along the control line, signaling visually that the test is valid. 
    The intensity of the test line increases in proportion to the hs-CRP concentration.


    Warnings and Precautions:
    1. Use for in vitro diagnostics.
    2. Use by healthcare professionals.
    3. The best testing temperature is 15~30 ℃, and the best humidity is 40~60%.
    4. Do not use the strip beyond the expiration date printed on the outside of the box.
    5. The strip must be used within 1 hour once its foil pouch has been opened.
    6. The transfer pipette should be used for one specimen only. Discard it after used.
    7. Patient specimens, used strip and transfer pipettes may be potentially infectious. 
    Proper handling and disposal methods should be established by the laboratory 
    direction in accordance with local regulations.

    8. Proper laboratory safety techniques should be followed at all times when 
    working with potentially infectious blood specimens.


    Company: Nanjing Perlove Medical equipment Co.,Ltd.
  • One Step Test for Antibody to Hepatitis C Virus

    One Step Test for Antibody to Hepatitis C Virus

    Intended Use:
    This test is used for the qualitative detection of antibody to Hepatitis C Virus 
    (HCV) in serum/plasma samples. It can be used to screen for HCV in the scene
     for blood donation and for in vitro diagnostic use.

    Principle of the Procedure:
    This product uses colloidal gold immunochromatography to detect HCV antibodies
     in serum/plasma samples qualitatively.During the detection,HCV antibodies in the 
    samples combine with colloidal gold-labeled antigens and then form antigen-antibody complexes.The sample passes through the detection zone, in which the
     sandwich complexes gather along a line, appearing as a purplish red streak 
    (the test or signal line). Excess gold-labeled antigens gather along the control line, 
    signaling visually that the test is valid.

    Warnings and Precautions:
    1. Use for in vitro diagnostics.
    2. Use by healthcare professionals.
    3. Do not use the strip beyond the expiration date printed on the outside of the box.
    4. The strip must be used within 1 hour once its foil pouch has been opened.
    5. The transfer pipette should be used for one specimen only. Discard it after used.
    6. Patient specimens, used strip and transfer pipettes may be potentially infectious. 
    Proper handling and disposal methods should be established by the laboratory 
    direction in accordance with local regulations.

    7. Proper laboratory safety techniques should be followed at all times when 
    working with potentially infectious blood specimens.


    Company: Nanjing Perlove Medical equipment Co.,Ltd.
  • Human Immunodeficiency Virus Ⅰ&Ⅱ Rapid Test Kit

    Human Immunodeficiency Virus Ⅰ&Ⅱ Rapid Test Kit

    Intended Use:
    This test is used for the qualitative detection of Human Immunodeficiency Virus in 
    serum/plasma samples. It can be used to screen for HIV in the scene for blood 
    donation and for in vitro diagnostic use.

    Principle of the Procedure:
    This product uses colloidal gold immunochromatography to detect HIV1/2 
    antibodies in serum/plasma samples qualitatively.During the detection,HIV 
    antibodies in the samples combine with colloidal gold-labeled antigens and then 
    form antigen-antibody complexes. The sample passes through the detection zone,in which the 
    sandwich complexes gather along a line,appearing as a purplish red streak 
    (the test or signal line). Excess gold-labeled antigens gather along the control line, 
    signaling visually that the test is valid.

    Warnings and Precautions:
    1. Use for in vitro diagnostics.
    2. Use by healthcare professionals.
    3. Do not use the strip beyond the expiration date printed on the outside of the box.
    4. The strip must be used within 1 hour once its foil pouch has been opened.
    5. The transfer pipette should be used for one specimen only. Discard it after used.
    6. Patient specimens, used strip and transfer pipettes may be potentially infectious. 
    Proper handling and disposal methods should be established by the laboratory 
    direction in accordance with local regulations.

    7. Proper laboratory safety techniques should be followed at all times when 
    working with potentially infectious blood specimens.


    Company: Nanjing Perlove Medical equipment Co.,Ltd.
  • One Step Test for Hepatitis B Surface Antigen

    One Step Test for Hepatitis B Surface Antigen

    Intended Use:
    This product is used for the qualitative detection of Hepatitis B Surface Antigen
     (HBsAg) in serum/plasma samples. It can be used to screen for HBsAg in the 
    scene for blood donation and detect HBsAg before clinical emergency operation.

    Principle of the Procedure:
    This product uses colloidal gold immunochromatography to detect HBsAg in 
    serum/plasma samples qualitatively.The antigens HBsAg in the blood sample 
    combine with colloidal gold-labeled recombinant antibodies (Au-sAb1), and then
     form antigen-antibody complexes. The sample passes through the detection zone, in which the 
    sandwich complexes gather along a line, appearing as a purplish red streak 
    (the test or signal line). Excess gold-labeled antibodies gather along the control 
    line, signaling visually that the test is valid.

    Warnings and Precautions:
    1. Use for in vitro diagnostics.
    2. Use by healthcare professionals.
    3. Do not use the strip beyond the expiration date printed on the outside of the box.
    4. The strip must be used within 1 hour once its foil pouch has been opened.
    5. Patient specimens and used strip may be potentially infectious. Proper handling
     and disposal methods should be established by the laboratory direction in 
    accordance with local regulations.

    6. Proper laboratory safety techniques should be followed at all times when 
    working with potentially infectious blood specimens.


    Company: Nanjing Perlove Medical equipment Co.,Ltd.
Select to
If you still cannot find what you want, please directly email to service@industry-medical.com, OR post your buy offer.
Page 10 of 11    ...... 10
Go to Page