  • Portable x-ray unit(ET-10)

    FEATURES:
    shock-proof, radiation-proof,  fixed anode ,self-rectified
    composed head  ,stable petformance,easy operation,
    graceful model and easy movement .

    SPECIFICATIONS:
    Max fluoroscopy: 75kvp 3-5ma (uncontinuous use)recommend fluoroscopy  condition :65kvp 3ma
    max radiography: 75kvp  10ma 6sec (pause 3min)
    power current:ac220v±10% ,50hz,kva
    power  current:2a(uncontinuous fluoroscopy)6a(uncontinuous radiography)
    range of  movement:vertical: 220 mm ,horizontal;130mm tube  turning  angle:vertical360 ,horizontal 320
    size of screen:203mm x 254mm



    Company: Etai Medical Co.,Ltd.
  • 100mA X-RAY MACHINE
    Application:
    Routine Radiography
    Bucky Radiography
     
    Composition:
    Control desk     high-voltage generator unit     high voltage cable      X-ray tube assembly
     
              Radiographic table-pillar of X-ray source        collimator
            
    Chest film stand (optional composition)
     
     
    Feature:
    1.       Single table, single tube
    2.       Design according to the electric mechanism of middle-size machine, with complete and reasonable function
    3.       High-voltage system is of spilt structure, with high-voltage generator of full-wave rectification. independent X-ray tube unit, large output power and reliable and stable operation
    4.       Power voltage (V), radiograph kilovolt (KV) and infinitely variable control
    5.       Be equipped with the manostat for the filament of X-ray tube and space charge compensator to ensure the stable and exact output
    6.       Be equipped with capacity limit protective circuit----KvmAs interlock limit protection
    7.       The timer circuit grades according to R10 priority coefficient has an exact time control
    8.       The radiographic flat table has a vibrating ray-filter
    9.       The pillar has only the bottom track, with easy installation


    Company: Etai Medical Co.,Ltd.
  • 100mA X-RAY MACHINE

    UNIT CONFIGURATION
     
    Control desk     high-voltage generator unit     high voltage cable      X-ray tube assembly
     
              Radiographic table-pillar of X-ray source        collimator
            
    Chest film stand (optional composition)
     
    USE
    Fluoroscopy
    Digestive track spot film radiography

    General radiography
    Filter-ray device radiography
     
    MAIN CHARACTERISTICS
    1. Single bed and single tube
    2. Design according to the electric medhanism of middle-size machine. The function is full and reasonable.
             3. The high-tension system is of march-past structure. Equipped with afullwave rectification high-voltage generator and ifdependent X-ray tube unit, with large output power and reliable and stable operation.
    4. Supply voltage V, roentgenoscopy, photograpy kV and stepless adjustable.
    5. Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to ensure the stable and accurate output.
    6. Equipped with the capacity limitation and protection circuit and kV mA s interlock limitation and protection.
    7.Adopt the digital circuit timer, grade according to R10 prioritycoefficient and can control time exactly.
    8. Diagnostic bed id of electric back rotation and is equipped with vibrating filter-ray device.
    9. The spot film device of fluoroscent screen can hole the film jecket of various sizes and can make the photograpy of full-film and half films separately.
             10. The upright post has the bottom track only, which is easy while instalation.
     
     
    MAIN TECHNICAL DATA: 
    ITEM CONTENT   INDEX 
    Roentgenoscopy voltage  40∼95kV 40∼100kV
    current 0.5∼5mA
    Photograpy voltage 40∼90kV 40∼100kV
    current small focus 15mA and big focus 3060100mA four grades together
    spot film 100mA(fixed)
    time 0.04∼6.3s grades togeter 
    High-voltage generator  capacity 10kVA
    Max dc output voltage 95kV 100kV 
    Min dc output voltage 100mA 125mA 
    X-ray tube model  XD4∼2.9/100
    focus small focus 1.8mm bitg big focus 4.3mm
    Examining bed  rotary angle +90°∼0°∼-5°
    specifi-cation of spot film(gastrointestinal photograpy) 128×179mm(5"×7")  
    205×154mm(8"×10")  
    254×305mm(10"×12")  
    Upright post  move lengthwis(along the bottom track)  ≥1500mm 
    move transverse ≥360mm 
    move up and down(along upright post) 720∼1720mm(from focus to ground) 

    Supply power  voltage  single phase 380V/220V 
    frequency  50Hz ± 0.5Hz 
    capacity 10KVA 
    inner resistance  380V:2 Ω ,220V:0.6 Ω 


    MAX CAPACITY OF HPOTOGRAPY
    Focus of X-ray tube  photograph mA Max photograph KV  max allowable exposure time 
    Small focus  25mA  90kV 100kV 1.0s 
    Big focus 50 mA  90KV 95KV 6.3s 
    100 mA  85KV 90KV 2.5s 
    125 mA  85KV 1.0s 



    Company: Etai Medical Co.,Ltd.
  • 200mA X-ray machine

    Application:
    Routine Radiography
    Bucky Radiography
    Composition:
    Control desk   
    high-voltage generator   
    high voltage cable  
    X-ray tube assembly
    Radiographic table
    -pillar of X-ray source
    collimator
     
    Characteristics:
    1. The power supply voltage V and KV are infinitely variable control.
    2. The machine is equipped with mA, KV and S interlocking protecting device of subsections and grades.
    3. The machine is equipped with the protection device of X-ray filament manostat, space charge compensation and anode start.
    4. Power supply voltage, radiographic KV and mA display separately and are observed easy.
    5. The machine with no top and bottom track is installed and operated easy.
    6. Transverse moving of upright post, lengthways moving of arm and rotation of X-ray tube unit are all equipped with electromagnetism braking device.
    7. Diagnostic bed, which is equipped with electromagnetism braking device, can move not only transversely but also lengthwise.



    Company: Etai Medical Co.,Ltd.
  • 200mA X-ray machine

    USE

    Roentgenoscopy; Digestive track spot film photograpy; General photograpy; Filter-ray device photograpy

    MAIN TECHNICAL PARAMETER
    1. Single bed and single tube
    2. Rotary anode X-ray tube unit and tangential pipe sleeve.
    3. monophase full-wave rectification high-voltage generator.
    4. Supply voltage V, roentgenoscopy and photograpy kV, infinitely variable control and electric mechanism.
    5. Equipped with capacity protective circuit,and kV mAs sectional and graduated interlock protection.
    6. Equipped with the manostat for filament of X-ray tube and equipped with space-charge compensator.
    7. Adopt the digital circuit timer, grade according to R10 priority coefficient and can control time exactly.
    8. Equipped with the digital circuit device for roentgenoscopy time accumulation.
    9. Examining bed is of electric back rotation, with external balance structure and with vibrating filter-ray device.
    10. The spot film device of luminescent screen can hold the film jacket of various sizes and solenoid valve locking.
    11. Upright post is of top and bottom track. It moves lightly.
     
     
    ITEM CONTENT  INDEX 
    Fluoroscopy voltage 40100kV be adjustable continuously 
    current  0.55mA 
    Photograpy voltage 40100kVbe adjustable continuously 40125kV be adjustable 
    current small focus 50mA and big focus 30 100 150 200mA,five grades 
    spot film  150mA( fixed )
    time 0.046.3s 23 grades together 
    High-voltage generator  capacity 20kVA( instantaneous ) 
    Max dc output voltage  100KV 125KV  
    Max dc output current  200mA 
    X_ray tube  model  XD51-20.40/100 XD51-20.40/125  
    focus  1×1mm 2×2mm 
    Examining bed  rotary angle  +90° 0 ° -10° 
    movable range of spot film device(stomach and intestines photograpy)  lengthwise 580mm
    transverse ± 90mm
    pressure down 300mm
    specification of spot film  127×177.8mm(5×7) 
    203.2×254mm(8×10)
    254×304.8mm(10×12) 
    279.4×355.6mm(11×14) 
    filter-ray grid characteristic  N28 
    converging distance  fo 100cm 
    grid proportion  r8 
    distance between bed face and film  70mm
    collimator manual single blade 
    Upright adjusting scope(distance between top and bottom track)  2800-3400mm 
    move lengtwise (along top and bottom track)  3100mm
    move transverse(along horizontal arm ) 800mm( from bulb focus to he centre of upright post)
    move up and down (along upright post) 3251830mm( from bulb focus to groud) 
    Power supply  Voltage  380V/220V 
    Frequency 50Hz ± 0.5Hz 
    Inner resistance  380V:0.9 Ω ,220V:0.3 Ω 


    UNIT CONFIGURATION
     
    Control desk     high-voltage generator unit    

    high voltage cable      X-ray tube assembly

    Radiographic table-pillar of X-ray source       

    collimator



    Company: Etai Medical Co.,Ltd.
  • 200mA X-ray machine
    USE

    Fluorscopy
    Gastrointestinall radiography
    General radiography
    Ray-filter-ray radiography

    MAIN CHARACTERISTICS:
    Two tables and two tubes X-ray machine is separate and special, with fluoroscopy, gastrointestinal photography, general photography, filter-ray photography.
    Three parameters kV mA and s are sectional interlocked protection in capacity.
    Both fluoroscopy and photography are equipment with limited time protection fittings.
    Equipment with protection of the manostat for filament of X-ray tube, Space charge compensating, Rotary anode starting and overrunningtemperature protection.
    Supply power V, fluoroscopy kV, photography kV and motor adjusts continuously.
    Equipment with the electric diagnostic bed, fluorescent photography device and electromagnetism locks
    The photography table can be used professionally, operated expediently, the ground-track is selected fittings when using .

    QUALITY PARAMETERS:
     
    ITEM CONTENT INDEX
    Outer power Capacity 25KVA
    Ultuge freguency 380V/220V±10% 50Hz±1Hz
    Inner resistanle at 380V:0.9Ω; at 220V:0.3Ω
    Supply control Scope 380V±10% being adjustable or 220V±10% being adjustable
    High-volage generator Max-capacity 20kVA(instantaneous)
    Max Dc output voltage 125kVP
    Max Dc output cunent 200mA(instantaneous)
    Fluorscopy Tube voltage 50~100kV being adjustable
    Tube cunent 0.5~5mA being adjustable
    Gastrointestinall radiography Tube voltage 50~110kVP
    Tube cunent 150mA(fixed)
    Fluorscopy Gastrointestinall radiography X-Ray tube Focus small focus 1×1mm; big focus 2×2mm
    Model XD51-2040/125
    General radiographyfilter-ray radiography Tube voltage 50~125kVP
    Tube cunent small focus 50100mA; big focus 50100150200mA
    Raiography X-Ray tube Focus small focus 1×1mm, big focus 2×2mm
    Model XD51-2040/125

    Dnagnostic bed Rotary scope
    Bed L×W×H 1960×702×820mm

    Fluorscopy Gastrointestinall radiography equipment Horizontal about ±90mm
    Up and down 580mm
    Lock mode The electromagnetism locks
    Light control Manual limit beam single leaf
    Photograph specification 128×179mm(5×7)Whole slice two cents slice
    205×254mm(8×10)Whole slice two cents slice
    254×305mm(10×12) Whole slice two cents slice
    279×355mm(11×14) Whole slice four cents slice

    Radiography bed L×W×H(mm)  2000×710×700mm
    Lengthwise 700mm
    Transrerse 

    Vihration Ray-filter device Travel in length 550mm
    Grid clennsity N28
    grid ratio r8
     Convergence distance f0100cm

    X-Ray tube unit-support Lengthwise 2100mm
    Up and down 325~1825mm
    Tube turning around the shaf of arm 180°
    Turning around the shaft of tube -10°~90°~120°


    Unit Configuration
     
    Control desk
    high-voltage generator unit  X-ray Tube unit support I     
    Diagnostic Bed               X-ray Tube unit support II      
    Radiography bed              Stanal radiography post


    Company: Etai Medical Co.,Ltd.
  • 300mA X-ray machine

    Application:
    Routine Radiography
    Bucky Radiography
    Composition:
    Control desk     high-voltage generator     high voltage cable    X-ray tube assembly
    Radiographic table    -pillar of X-ray source       collimator       
    Chest film stand (optional composition)
     
    Feature:
    1. One table, one tube
    2. Single-phase, full wave, high voltage rectification
    3. Rotary anode x-ray assembly and tangential pipe sleeve IEC plug and plug base
    4. Supply voltage. radiography KV, infinitely variable control and electric mechanism
    5. Equipped with capacity protective circuit, and KV mAs sectional and graduated interlock protection
    6. Controller is equipped with electric autotransformer, easy to adjust
    7. Equipped with the manostat for filament of X-ray tube and equipped with space-charge compensator
    8. Adopt the digital circuit timer, grade according to R10 priority coefficient and can control time exactly
    9. High-voltage primary uses the zero controlled circuit of silicon-controlled rectifier of large power



    Company: Etai Medical Co.,Ltd.
  • Vertical Bucky Stand (ET-LS)

    USE
    ETLS Vertical Bucky Sand, which Bucky grid oced up and down, is a photograph device, It can be used as a photograph auxiliary device in ETseies Medical XRay machine of our company or others. It can photograph including Bresst, Belly,Joint,the foor limbs so on.
    CHARACTERISTICS
    Structure close, area small on the ground, install convenience
    Moved up and down protable, manual lock freely
    The short distance from table to film can guarantee photograph high uality and little distortion
    Support frame noiseless, cassette may direct into, operate convenience
    Fixde Bucky no power(or electromotor oscillating grid)

    CONSTITUT
    Stand, Adjust Frame and Buchy(import and fixed)
    QUALITY PARAMETERS
    Vertical movements  >500mm∼1600mm
    Size of film  203mm×254mm(8×10) ∼356mm×432mm(14×10)
     
    FIXED BUCKY X-RAY GRID INDEXES     
    film:  15×18  
    40L/cm Densilty N :  40L/cm  
    Grid proportion r:  81  
    Converging focus distance fo:  1800mm  
     



    Company: Etai Medical Co.,Ltd.
  • X-RAY MACHINE,200MA A03.02002

    1.Single bed and single bulb.

    2.Design according to the electric mechanism of middle-size machine.The function is full and reasonable.

    3.The high-tension system is of march-past structure.Equipped with afullwave rectification high-voltage generator and independent X-ray tube unit,with large output power and reliable and stable operation.

    4.Supply voltage V,roentgenoscopy,photograpy KV and stepless adjustable.

    5.Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to ensure the stable and accurate output.

    6.Equipped with the capacity limitation and protection circuit and KvmA sinterlock limitation and protection.

    7.Adopt the digital circuit timer,grade according to R10 prioritycoefficient and can control time exactly

    8.Examining bed is of electirc back rotation and is equipped with vibrating filter-ray device.

    9.The spot film device of luminescent screen can hold the film jacket of various sizes and can solenoid valve locking.

    10.The upright post is of top and bottom track.It moves lightly.


     



    Company: Nanjing Everich Medicare Import & Export Co.,Ltd
  • 50mA Bedside X-ray Unit

    This equipment is commonly used in ward and emergency treatment room for radiography.
    main charactor:
    Combined X-ray generator.
    Single focus, Bridge rectification.
    It is precise,safe,reliable and flexible.
    Remote control device(control range is over 5m) is available.
    Main Technical Data:
    X-ray Generator
    Stationary Anode,Single focus,and bridge silicon rectification, The X-ray Generator is an oil-immersed self-cooled unit
    Max Rated Capacity
    Current   50mA  30mA
    Voltage   90kvp 90kvp
    Time:     2s    6.3s
    Power supply
    Voltage:   180-240V
    Frequency:   50Hz
    Power: Not lower than 5Kva
    Resistance:  not large than 1
    Voltage Adjustment range of x-ray tube
    45-90Kvp,Divided into 10 steps
    Range of the timer   0.08-6.3s
    Distance between the focus to the screen   600-1630mm
    X-ray Tube
    Longitudinal movement: 240mm; Transverse rotation:  60
    Specification of X-ray Tube
    Model:XD3-3.5/100 Fixed anode,single focus 2.6mm
    Packing:1set/Woodencase, 1040x755x2050
    Net weight:  127kgs
    Gross weight: 205kgs



    Company: Nanjing Everich Medicare Import & Export Co.,Ltd